Related papers: Calibration and localization of optically pumped m…
The paper proposes a novel calibration approach for the Orthoglide-type mechanisms based on observations of the manipulator leg parallelism during motions between the prespecified test postures. It employs a low-cost measuring system…
Airborne magnetometry requires rigorous calibration to isolate geomagnetic signals from sensor errors and platform magnetic fields. This magnetic compensation is needed for applications like geophysical exploration and magnetic anomaly…
Herein, an atomic norm based method for accurately estimating the location and orientation of a target from millimeter-wave multi-input-multi-output (MIMO) orthogonal frequency-division multiplexing (OFDM) signals is presented. A novel…
We present a method for measuring the magnetic field that allows hyperfine and Zeeman optical pumping, excitation and detection of magnetic resonance by means of a single laser beam with time-modulated ellipticity. This improvement allows…
When optically pumped magnetometers are aimed for the use in Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement result. Measurement errors and inaccuracies…
Background: Calculation of the electric field induced by transcranial magnetic stimulation (TMS) in the brain requires accurate models of the stimulation coils. Reconstructing models from the measured magnetic fields of coils so far worked…
We study the position estimation of a mechanical oscillator undergoing both detuned parametric amplification and continuous quantum measurement. This model, which can be utilised to produce squeezed states, is applied to a general…
The magnetic localization method has been widely studied, which is mainly based on the accurate mapping of the magnetic field generated by magnetic sources. Many factors affect localization accuracy in the experiment. Therefore, this paper…
The Full-disk magnetograph is a main scientific payload onboard the Advanced Space based Solar Observatory (ASO-S/FMG) that through Stokes parameter observation to measures the vector magnetic field. The accuracy of magnetic-field values is…
Linear Hall sensors are a cost-effective alternative to optical encoders for measuring the rotor positions of actuators, with the main challenge being that they exhibit position-dependent inaccuracies resulting from manufacturing…
Magnetometer and inertial sensors are widely used for orientation estimation. Magnetometer usage is often troublesome, as it is prone to be interfered by onboard or ambient magnetic disturbance. The onboard soft-iron material distorts not…
We present a comprehensive method for visualisation and quantification of the magnetic stray field of magnetic force microscopy (MFM) probes, applied to the particular case of custom-made multi-layered probes with controllable high/low…
We present the concept and the results of an investigation of an all-optical vector magnetic field sensor scheme developed for biological applications such as non-zero field magnetoencephalography and magnetocardiography. The scheme differs…
The Bell-Bloom-type optically pumped atomic magnetometers are well suited for weak geomagnetic field detection. However, conventional single-beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy…
Electrically conductive objects can be detected using the principle of electromagnetic induction where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be…
We present an all-optical method to measure and compensate for residual magnetic fields present in a cloud of ultracold atoms trapped in an optical dipole trap. Our approach leverages the increased loss from the trapped atomic sample…
We have developed an individual identification system based on magnetocardiography (MCG) signals captured using optically pumped magnetometers (OPMs). Our system utilizes pattern recognition to analyze the signals obtained at different…
The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in…
This paper investigates the magnetic fields produced by a three-coil system, focusing on how different mesh resolutions affect the accuracy of the results. Using both the Poisson solver, as well as a numerical approach based on the solution…
A new system for precise measurements of the field integrals and multipole components of the APS magnetic insertion devices is described. A stretched coil is used to measure magnetic field characteristics. The hardware includes a number of…