Related papers: Multi-Material Blind Beam Hardening Correction Bas…
Due to the energy-dependent nature of the attenuation coefficient and the polychromaticity of the X-ray source, beam hardening effect occurs when X-ray photons penetrate through an object, causing a nonlinear projection data. When a linear…
Doing quantitative computed tomography (CT) using Bremsstrahlung sources requires an estimate of the spectrum emitted by the X-ray source. One method of beam hardening correction (BHC), as described by Lifton[1], first uses transmission…
In clinical CT, the x-ray source emits polychromatic x-rays, which are detected in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral model on the basis of the Beer-Lambert…
This paper proposes a sinogram consistency learning method to deal with beam-hardening related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent…
This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…
We describe the results from a simulation and experimental study of density estimation and beam hardening correction for Bremsstrahlung source computed tomography scan of objects made of a single material. The correction is done using…
Dark-field radiography is a novel X-ray imaging modality that enables complementary diagnostic information by visualizing the microstructural properties of lung tissue. Implemented via a Talbot-Lau interferometer integrated into a…
Blind pansharpening addresses the problem of generating a high spatial-resolution multi-spectral (HRMS) image given a low spatial-resolution multi-spectral (LRMS) image with the guidance of its associated spatially misaligned high…
Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise.…
This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…
The intensity of a monochromatic X-ray beam decreases exponentially with the distance it has traveled inside a material; this behavior is commonly referred to as Beer-Lambert's law. Knowledge of the material-specific attenuation coefficient…
Spectral computed tomography (CT) has a great potential in material identification and decomposition. To achieve high-quality material composition images and further suppress the x-ray beam hardening artifacts, we first propose a one-step…
We develop a method for sparse image reconstruction from polychromatic computed tomography (CT) measurements under the blind scenario where the material of the inspected object and the incident-energy spectrum are unknown. We obtain a…
Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design…
We present new methods for lensing reconstruction from CMB temperature fluctuations which have smaller mean-field and reconstruction noise bias corrections than current lensing estimators, with minimal loss of signal-to-noise. These biases…
Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…
Computed tomography is a method for synthesizing volumetric or cross-sectional images of an object from a collection of projections. Popular reconstruction methods for computed tomography are based on idealized models and assumptions that…
X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we…
We study streaking artifacts caused by beam-hardening effects in X-ray computed tomography (CT). The effect is known to be nonlinear. We show that the nonlinearity can be recovered from the observed artifacts for strictly convex bodies. The…
Multispectral computed tomography (CT) enables advanced material characterization by acquiring energy-resolved projection data. However, since the incoming X-ray flux is be distributed across multiple narrow energy bins, the photon count…