English
Related papers

Related papers: Low-rank flat-field correction for artifact reduct…

200 papers

Low Dose Computed Tomography suffers from a high amount of noise and/or undersampling artefacts in the reconstructed image. In the current article, a Deep Learning technique is exploited as a regularization term for the iterative…

Image and Video Processing · Electrical Eng. & Systems 2019-06-04 Shabab Bazrafkan , Vincent Van Nieuwenhove , Joris Soons , Jan De Beenhouwer , Jan Sijbers

Filtered back projection (FBP) is the most widely used method for image reconstruction in X-ray computed tomography (CT) scanners. The presence of hyper-dense materials in a scene, such as metals, can strongly attenuate X-rays, producing…

Computer Vision and Pattern Recognition · Computer Science 2019-08-02 Muhammad Usman Ghani , W. Clem Karl

Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading…

Image and Video Processing · Electrical Eng. & Systems 2022-02-09 Chang Min Hyun , Taigyntuya Bayaraa , Hye Sun Yun , Tae Jun Jang , Hyoung Suk Park , Jin Keun Seo

In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…

Medical Physics · Physics 2016-04-07 Shi-peng Xie , Rui-ju Yan

Although augmentations (e.g., perturbation of graph edges, image crops) boost the efficiency of Contrastive Learning (CL), feature level augmentation is another plausible, complementary yet not well researched strategy. Thus, we present a…

Machine Learning · Computer Science 2022-12-05 Yifei Zhang , Hao Zhu , Zixing Song , Piotr Koniusz , Irwin King

In many applications of tomography, the acquired projections are either limited in number or contain a significant amount of noise. In these cases, standard reconstruction methods tend to produce artifacts that can make further analysis…

Numerical Analysis · Mathematics 2016-04-11 D. M. Pelt , K. J. Batenburg

High-quality imaging in photoacoustic computed tomography (PACT) usually requires a high-channel count system for dense spatial sampling around the object to avoid aliasing-related artefacts. To reduce system complexity, various image…

Image and Video Processing · Electrical Eng. & Systems 2024-09-24 Bowei Yao , Shilong Cui , Haizhao Dai , Qing Wu , Youshen Xiao , Fei Gao , Jingyi Yu , Yuyao Zhang , Xiran Cai

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

Image and Video Processing · Electrical Eng. & Systems 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

We present a novel approach to handle ring artifacts correction in compressed sensing tomographic reconstruction. The correction is part of the reconstruction process, which differs from classical sinogram pre-processing and image…

Computational Physics · Physics 2016-05-11 Pierre Paleo , Alessandro Mirone

In this work, we develop a novel technique for reconstructing images from projection-based nano- and microtomography. Our contribution focuses on enhancing reconstruction quality, particularly for specimen composed of homogeneous material…

Computer Vision and Pattern Recognition · Computer Science 2025-09-09 Anuraag Mishra , Andrea Gilch , Benjamin Apeleo Zubiri , Jan Rolfes , Frauke Liers

In electrical impedance tomography, algorithms based on minimizing the linearized-data-fit residuum have been widely used due to their real-time implementation and satisfactory reconstructed images. However, the resulting images usually…

Analysis of PDEs · Mathematics 2019-03-25 Bastian Harrach , Mach Nguyet Minh

The most ubiquitous form of computational aberration correction for microscopy is deconvolution. However, deconvolution relies on the assumption that the point spread function is the same across the entire field-of-view. This assumption is…

Image and Video Processing · Electrical Eng. & Systems 2025-04-30 Amit Kohli , Anastasios N. Angelopoulos , David McAllister , Esther Whang , Sixian You , Kyrollos Yanny , Federico M. Gasparoli , Bo-Jui Chang , Reto Fiolka , Laura Waller

Spectral computed tomography (CT) reconstructs material-dependent attenuation images with the projections of multiple narrow energy windows, it is meaningful for material identification and decomposition. Unfortunately, the multi-energy…

Computer Vision and Pattern Recognition · Computer Science 2018-10-30 Weiwen Wu , Fenglin Liu , Yanbo Zhang , Qian Wang , Hengyong Yu

X-ray-induced acoustic computed tomography (XACT) as a novel imaging modality has shown great potential in applications ranging from biomedical imaging to nondestructive testing. Improving the signal-to-noise ratio and removing the…

Medical Physics · Physics 2024-04-10 Mohamed Elsayed Eldib

We present a novel neural surface reconstruction method called NeuralRoom for reconstructing room-sized indoor scenes directly from a set of 2D images. Recently, implicit neural representations have become a promising way to reconstruct…

Computer Vision and Pattern Recognition · Computer Science 2022-11-29 Yusen Wang , Zongcheng Li , Yu Jiang , Kaixuan Zhou , Tuo Cao , Yanping Fu , Chunxia Xiao

In recent years, the development of Neural Radiance Fields has enabled a previously unseen level of photo-realistic 3D reconstruction of scenes and objects from multi-view camera data. However, previous methods use an oversimplified pinhole…

Computer Vision and Pattern Recognition · Computer Science 2024-06-18 Yi Hua , Christoph Lassner , Carsten Stoll , Iain Matthews

Limited-angle X-ray tomography reconstruction is an ill-conditioned inverse problem in general. Especially when the projection angles are limited and the measurements are taken in a photon-limited condition, reconstructions from classical…

Image and Video Processing · Electrical Eng. & Systems 2021-12-21 Zhen Guo , Jung Ki Song , George Barbastathis , Michael E. Glinsky , Courtenay T. Vaughan , Kurt W. Larson , Bradley K. Alpert , Zachary H. Levine

Multispectral computed tomography (CT) enables advanced material characterization by acquiring energy-resolved projection data. However, since the incoming X-ray flux is be distributed across multiple narrow energy bins, the photon count…

The task of segmentation of multispectral images, which are images with numerous channels or bands, each capturing a specific range of wavelengths of electromagnetic radiation, has been previously explored in contexts with large amounts of…

Computer Vision and Pattern Recognition · Computer Science 2024-11-26 Dilith Jayakody , Thanuja Ambegoda

Metal artifacts is a major challenge in computed tomography (CT) imaging, significantly degrading image quality and making accurate diagnosis difficult. However, previous methods either require prior knowledge of the location of metal…

Image and Video Processing · Electrical Eng. & Systems 2023-06-21 Jiandong Su , Ce Wang , Yinsheng Li , Kun Shang , Dong Liang
‹ Prev 1 4 5 6 7 8 10 Next ›