Related papers: Magnetic Field Analysis for Fermilab Muon $g-2$
The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_\mu$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at…
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3$\sigma$ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140…
The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession…
The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the…
This paper will cover the physics and methods behind Fermilab's Muon g-2 Experiment, along with the long-awaited results from Run-1. The experiment was undertaken to resolve the tension between the Standard Model and the previous…
The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab has a goal of measuring the muon anomaly ($a_\mu$) with unprecedented precision using positive muons. This measurement is motivated by the difference between the previous Brookhaven…
The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
A new experiment at Fermilab will measure the anomalous magnetic moment of the muon with a precision of 140 parts per billion (ppb). This measurement is motivated by the results of the Brookhaven E821 experiment that were first released…
The muon anomalous magnetic moment, $a_\mu = (g-2)/2$, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics.…
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the…
The muon magnetic anomaly, $a_{\mu}$, is a powerful test of the Standard Model of particle physics. A new experiment at Fermilab has recently measured $a_{\mu}$ with unprecedented precision, confirming the results of the earlier Brookhaven…
The precise measurement of the muon anomalous magnetic moment $a_\mathrm{\mu}$ has stimulated much theoretical and experimental efforts over more than six decades. The last experiment at Brookhaven National Laboratory, Upton, NY, USA…
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_\mu \equiv (g_\mu-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_\mu = (g^{}_\mu-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018.…
The Fermilab Muon $g-2$ experiment measures the muon anomalous magnetic moment with high precision. Together with recent improvements on the theory front, the first results of the experiment confirm the long-standing discrepancy between the…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…
The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was…
The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment $a_{\mu}$ . This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation…