Related papers: Additive manufacturing of fine-granularity optical…
Fast emitting polymeric scintillators are requested in advanced applications where high-speed detectors with large signal-to-noise ratio are needed. However, their low density implies a weak stopping power of high energy radiations, thus a…
Cryogenic detectors have a long history of success in the field of rare event searches. In particular scintillating calorimeters are very suitable detectors for this task since they provide particle discrimination: the simultaneous…
Neutron detectors are extensively used at many nuclear research facilities across Europe. Their application range covers many topics in basic and applied nuclear research: in nuclear structure and reaction dynamics (reaction reconstruction…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…
The advent of the silicon photomultiplier has allowed the development of highly segmented calorimeters using plastic scintillator as the active media, with photodetectors embedded in the calorimeter, in dimples in the plastic. To reduce the…
Heavy crystal scintillators are used widely in HEP experiments for precision measurements of photons and electrons. Future HEP experiments, however, require crystal scintillators of more bright, more fast, more radiation hard and less cost.…
A novel plastic scintillator, referred to as J-PET scintillator, has been developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole…
Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…
We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid…
Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring…
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…
We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a $\sim$6$\times$6$\times$45 cm$^3$ (13 $X_0$ depth)…
The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind…
Using scintillator tile technology several square meters of plastic scintillator are read out by only two photomultiplier with a time precision of about 1.5 nsec. Two examples are discussed to build a detector based on this technology to…
Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon,…
In this work, the simulation of optical photons is carried out in an antineutrino detector module consisting of a plastic scintillator connected to light guides and photomultipliers on both ends, which is considered to be used for remote…
Detectors based on polystyrene scintillator strips with WLS fiber readout are widely used to register charged particles in many high-energy physics experiments. The fibers are placed into grooves or holes along the strip. The detection…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
In recent years, the field of radiation detection has witnessed a paradigm shift with the emergence of plastic scintillators incorporating perovskite nanocrystals (PNCs). This innovative class of scintillators not only capitalizes on the…