Related papers: Phase-insensitive versus phase-sensitive ultrasoun…
The sensitivity in optical interferometry is strongly affected by losses during the signal propagation or at the detection stage. The optimal quantum states of the probing signals in the presence of loss were recently found. However, in…
Phase imaging techniques extract the optical path-length information of a scene, whereas wavefront sensors provide the shape of an optical wavefront. Since these two applications have different technical requirements, they have developed…
Phase super-sensitivity is obtained when the sensitivity in a phase measurement goes beyond the quantum shot noise limit, whereas super-resolution is obtained when the interference fringes in an interferometer are narrower than half the…
We present an algorithm for coherent diffractive imaging with phaseless measurements. It treats the forward model as a combination of coherent and incoherent waves. The algorithm reconstructs absorption and phase contrast that quantifies…
While characterization of coherent wavefields is essential to laser, x-ray and electron imaging, sensors measure the squared magnitude of the field, rather than the field itself. Holography or phase retrieval must be used to characterize…
We present a pressure sensor based on a Michelson interferometer, for use in photoacoustic tomography. Quadrature phase detection is employed allowing measurement at any point on the mirror surface without having to retune the…
In the last five decades, iterative phase retrieval methods draw large amount of interest across the research community as a non-interferometric approach to recover quantitative phase distributions from one (or more) intensity measurement.…
Phase-contrast imaging is an emerging technology that may increase the signal-difference-to-noise ratio in medical imaging. One of the most promising phase-contrast techniques is Talbot interferometry, which, combined with energy-sensitive…
A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of $e^{2r}$, where $r$ is the squeezing parameter [Phys.…
We present new techniques for inertial-sensing atom interferometers which produce multiple phase measurements per experimental cycle. With these techniques, we realize two types of multiport measurements, namely quadrature phase detection…
Phase-sensitive coherent imaging exploits changes in the phases of backscattered light to observe tiny alterations of scattering structures or variations of the refractive index. But moving scatterers or a fluctuating refractive index…
The hybrid interferometer integrating an optical parametric amplifier and a beam splitter has the potential to outperform the SU(1,1) interferometer. However, photon loss remains a critical limitation for practical implementation. To…
Detection of phase variations across optically transparent samples is often a difficult task. We propose and demonstrate a compact, lightweight and low cost quantitative phase contrast imager. Light diffracted from a pinhole is incident on…
Photon-number squeezing and correlations enable measurement of absorption with an accuracy exceeding that of the shot-noise limit. However, sub-shot noise imaging and sensing based on these methods require high detection efficiency, which…
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is…
We study an approach to solving the phase retrieval problem as it arises in a phase-less imaging modality known as ptychography. In ptychography, small overlapping sections of an unknown sample (or signal, say $x_0\in \mathbb{C}^d$) are…
Most reconstruction algorithms for photoacoustic imaging assume that the pressure field is measured by ultrasound sensors placed on a detection surface. However, such sensors do not measure pressure exactly due to their non-uniform…
Phase diffusion represents a crucial obstacle towards the implementation of high precision interferometric measurements and phase shift based communication channels. Here we present a nearly optimal interferometric scheme based on homodyne…
The sensitivity of the the pyramid wavefront sensor (PyWFS) has made it a popular choice for astronomical adaptive optics (AAO) systems, and it is at its most sensitive when it is used without modulation of the input beam. In non-modulated…