English
Related papers

Related papers: Characterization and Comparison of Glass Electrode…

200 papers

We report on the development of an GRPCs (Glass Resistive Plate chambers) Semi- Digital hadron calorimeter for the future International Linear Collider (ILC).Two types of GRPCs (small and 1m2) were tested in PS beam at CERN. Detector…

Instrumentation and Detectors · Physics 2010-08-24 Khaled Belkadhi

A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold…

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi

Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…

Instrumentation and Detectors · Physics 2025-03-21 A. Sen , S. Mandal , S. Chatterjee , S. Gope , S. Das , S. Biswas

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

Resistive plate chamber (RPC) is one of the state-of-the-art particle detection technology for the High Energy Physics (HEP) experiments. The basic operating mechanism of an RPC involves ionization of gas due to the passage of charged…

Instrumentation and Detectors · Physics 2020-12-30 Tanay Dey , Supratik Mukhopadhyay , Subhasis Chattopadhyay , Jhilam Sadukan

The India based Neutrino Observatory (INO) is a mega science project of India, which is going to use near about 30, 000 Resistive Plate Chambers (RPC) as active detector elements for the study of atmospheric neutrino oscillations. Each RPC…

Instrumentation and Detectors · Physics 2017-03-08 M. K. Singh , A. Kumar , N. Marimuthu , V. Singh , V. S. Subrahmanyam

We have recently developed an innovative detector of photons and charged particles: a GEM-like gaseous amplification structure with resistive electrodes instead of commonly used metallic ones. This novel detector combines the best property…

Instrumentation and Detectors · Physics 2010-05-12 P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

Instrumentation and Detectors · Physics 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto

The gas detector glass resistivity parallel chamber (GRPC) is proposed to use in the Hadron calorimeter (HCAL), the read-out system is based on the semi-digital system, then the charge information from GRPC is needed. To better understand…

Instrumentation and Detectors · Physics 2013-06-11 Han Ran

In this paper we would like to present a few characteristics of the Resistive Plate Chambers (RPC) made of a particular grade of bakelite paper laminates (P-120, NEMA LI-1989 Grade XXX), produced and commercially available in India. This…

Instrumentation and Detectors · Physics 2010-11-02 S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , S. Saha , Y. P. Viyogi

In this R&D, an innovative method for producing thin high-pressure laminate (HPL) electrodes for resistive plate chambers (RPC) for future high-energy experiments is introduced. Instead of using thick phenolic HPL (2-mm thick Bakelite),…

Instrumentation and Detectors · Physics 2025-06-05 Kyong Sei Lee , Giuseppe Iaselli , Youngmin Jo , Minho Kang , Tae Jeong Kim , Dayron Ramos Lopez , Gabriella Pugliese

Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…

Instrumentation and Detectors · Physics 2015-06-05 Diego Gonzalez-Diaz , Archana Sharma

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

Instrumentation and Detectors · Physics 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data…

We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and…

Instrumentation and Detectors · Physics 2015-05-18 P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

Keeping in mind the requirements of high rate capable, cost effective, large area detectors to be used in future high energy physics experiments, commercially available bakelite plates having moderate bulk resistivity are used to build an…

Instrumentation and Detectors · Physics 2024-01-25 Arindam Sen , Sayak Chatterjee , Shreya Roy , Saikat Biswas , Supriya Das