Related papers: High Spatial and Temporal Resolution NIR-IIb Gastr…
The scanning time for a fully sampled MRI can be undesirably lengthy. Compressed sensing has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is computationally complex and difficult…
Nasotracheal intubation (NTI) is a critical clinical procedure for establishing and maintaining patient airway patency. Machine-assisted NTI has emerged as a pivotal approach for optimizing procedural efficiency and minimizing manual…
Here we propose a new gamma-ray burst (GRB) mission, the Next Generation Rapid-Response GRB Observatory (NGRG). As with Swift, GRBs are initially located with a coded-mask X-ray camera. However, the NGRG has two new features: First, a…
The Gamma-ray instruments on-board INTEGRAL offer an unique opportunity to perform time resolved analysis on GRBs. The imager IBIS allows accurate positiioning of GRBs and broad band spectral analysis, while SPI provides high resolution…
Accelerated dynamic volumetric magnetic resonance imaging (4DMRI) is essential for applications relying on motion resolution. Existing 4DMRI produces acceptable artifacts of averaged breathing phases, which can blur and misrepresent…
Infrared (IR) spectroscopy, a type of vibrational spectroscopy, is widely used for molecular structure determination and provides critical structural information for chemists. However, existing approaches for recovering molecular structures…
The mid-infrared (MIR) region of the electromagnetic spectrum spans from 2- to 25-$\mu \mathrm{m}$, serving as a valuable tool for accessing rich chemical information. Functional groups, lipids, and other complex molecules can be analyzed…
Infrared (IR) imaging has become a viable tool for visualizing various chemical bonds in a specimen. The performance, however, is limited in terms of spatial resolution and imaging speed. Here, instead of measuring the loss of the IR beam,…
We propose a new benchmark for evaluating stereoscopic visual-inertial computer vision algorithms (SLAM/ SfM/ 3D Reconstruction/ Visual-Inertial Odometry) for minimally invasive surgical (MIS) interventions in the abdomen. Our MITI Dataset…
We investigate Hermite Gaussian Imaging (HGI) -- a novel passive super-resolution technique -- for complex 2D incoherent objects in the sub-Rayleigh regime. The method consists of measuring the field's spatial mode components in the image…
Endoscopic imaging is essential for real-time visualization of internal organs, yet conventional systems remain bulky, complex, and expensive due to their reliance on large, multi-element optical components. This limits their accessibility…
This study investigates the noise characteristics of intraoperative X-ray fluoroscopic images acquired during real-time image-guided radiotherapy (IGRT), and presents a novel noise image generation method based on the identified noise…
We present a robust imaging method based on time-correspondence imaging and normalized ghost imaging (GI) that sets two thresholds to select the reference frame exposures for image reconstruction. This double-threshold time-correspondence…
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce image quality and resolution, particularly in super-resolution techniques. While hardware-based adaptive optics, which correct aberrations…
Magnetic Resonance Imaging (MRI) is the gold standard in countless diagnostic procedures, yet hardware complexity, long scans, and cost preclude rapid screening and point-of-care use. We introduce Imageless Magnetic Resonance Diagnosis…
In this work, we investigate the use of spatio-temporalImplicit Neural Representations (INRs) for dynamic X-ray computed tomography (XCT) reconstruction under interlaced acquisition schemes. The proposed approach combines ADMM-based…
Phase-sensitive integrated photonic devices are highly susceptible to minor manufacturing deviations, resulting in significant performance inconsistencies. This variability has limited the scalability and widespread adoption of these…
Optical diffraction tomography (ODT) reconstructs a samples volumetric refractive index (RI) to create high-contrast, quantitative 3D visualizations of biological samples. However, standard implementations of ODT use interferometric…
Wireless capsule endoscopy (WCE) is a painless and non-invasive diagnostic tool for gastrointestinal (GI) diseases. However, due to GI anatomical constraints and hardware manufacturing limitations, WCE vision signals may suffer from…
Imaging with hard x-rays is an invaluable tool in medicine, biology, materials science, and cultural heritage. Propagation-based x-ray phase-contrast imaging and tomography have been mostly used to resolve micrometer-scale structures inside…