English
Related papers

Related papers: Towards a portable high-resolution muon detector b…

200 papers

The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…

Instrumentation and Detectors · Physics 2015-06-12 Y. Haddad , G. Grenier , I. Laktineh , N. Lumb , S. Cauwenbergh

The article considers a prototype module with sensitive dimensions of 2 x 0.5 m2 based on 2 m long straw tubes which preserves its geometrical dimensions up to the pressure of 4 bar independently of the ambient temperature and humidity. The…

Instrumentation and Detectors · Physics 2012-10-23 V. Peshekhonov , K. Davkov , V. Myalkovskiy , N. Russakovich , I. Zhukov

A new kind of Multi-gap Resistive Plate Chamber (MRPC) has been built for the large-area Muon Telescope Detector (MTD) for the STAR experiment at RHIC. These long read-out strip MRPCs (LMRPCs) have an active area of 87.0 x 17.0 cm2 and ten…

We propose a large-area, cost-effective Muon Telescope Detector (MTD) for the Solenoidal Tracker at RHIC (STAR) at mid-rapidity and for the next generation of detectors at a possible electron-ion collider. We utilize Multi-gap Resistive…

Driven by the recent improvement in additive manufacturing technologies, we designed a detector that can be fully printed with a standard and commercial 3D printer. The main goals of this research concern the marginal design and…

Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials. In this paper, a high spatial resolution muon tomography system based on Micromegas…

Instrumentation and Detectors · Physics 2022-02-16 Yu Wang , Zhiyong Zhang , Shubin Liu , Zhongtao Shen , Changqing Feng , Jianguo Liu , Yulin Liu

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

Muography is an innovative imaging technique using naturally produced elementary particles -- atmospheric muons -- like the X-rays of medical imaging. The modification of the particles flux -- by scattering or absorption --, reflects the…

Instrumentation and Detectors · Physics 2024-01-31 Theodore Avgitas , Jean Christophe Ianigro , Jacques Marteau

Cosmic-ray muons which impinge upon the Earth's surface can be used to image the density of geological and man-made materials located above a muon detector. The detectors used for these measurements must be capable of determining the muon…

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

A set of classical multi-wire proportional chambers were designed and constructed with the main purpose of efficient cosmic muon detection. These detectors are relatively simple to construct, and at the same time are low cost, making them…

Instrumentation and Detectors · Physics 2015-09-30 Dezső Varga , Zoltán Gál , Gergő Hamar , Janka Sára Molnár , Éva Oláh , Péter Pázmándi

The possibility to build a SiPM-readout muon detector (SiRO), using plastic scintillators with optical fibers as sensitive volume and readout by SiPM photo-diodes, is investigated. SiRO shall be used for tracking cosmic muons based on…

CMS experiment will use Resistive Plate Chambers (RPCs) as dedicated muon trigger detectors. The first 24 RPCs for the barrel muon system of the CMS experiment have been assembled and tested. A brief description of the cosmic muon telescope…

Instrumentation and Detectors · Physics 2010-11-19 Borislav Pavlov

In this paper we present a complete and detailed computational model of the response of the hybrid Muon Telescope (MuTe), designed to perform muography volcanic studies. This instrument combines two particle detection techniques: first, a…

We report on a feasibility study conducted at the ELBA facility at ELI Beamlines in 2025 to investigate the possible production of muons from high-energy electron beams generated by extended laser-plasma interactions in optically generated…

The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2015-06-22 A. Banerjee , A. Roy , S. Biswas , S. Chattopadhyay , G. Das , S. Pal

Muon radiography, also known as muography, is a non-destructive geophysical technique for the study of the internal structure of large objects such as volcanoes. This is possible by constructing an image based on the differential absorption…

Instrumentation and Detectors · Physics 2021-06-14 R. Calderón-Ardila , A. Almela , M. Gómez-Berisso , A. Sedoski , C. Varela , A. Vesga-Ramírez , H. Asorey

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

The muon detectors of the experiments at the Large Hadron Collider (LHC) have to cope with unprecedentedly high neutron and gamma ray background rates. In the forward regions of the muon spectrometer of the ATLAS detector, for instance,…

Instrumentation and Detectors · Physics 2016-10-04 B. Bittner , J. Dubbert , O. Kortner , H. Kroha , F. Legger , R. Richter , O. Biebel , A. Engl , R. Hertenberger , F. Rauscher

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive…