Related papers: Slice energy spread measurement in the low energy …
We present measurements of slice energy spread at the injector section of the European X-Ray Free Electron Laser for an electron bunch with charge of 250 pC. Two methods considered in the paper are based on measurements at the dispersive…
Ultrashort and ultracold electron bunches created by near-threshold femtosecond photoionization of a laser-cooled gas hold great promise for single-shot ultrafast diffraction experiments. In previous publications the transverse beam quality…
We have measured the total energy spread (99 persent energy spread) of the Booster beam at its injection energy of 400 MeV by three different methods - 1) creating a notch of about 40 nsec wide in the beam immediately after multiple turn…
We present measurements of slice energy spread growth due to quantum fluctuations of the undulator radiation at the European X-Ray Free-Electron Laser. The method uses a recently installed diagnostic wakefield structure, which enables…
Achieving maximum electron beam brightness in photoinjectors requires detailed control of the 3D bunch shape and precise tuning of the beam focusing. Even in state-of-the-art designs, slice emittance growth due to nonlinear space charge…
Intrabeam scattering (IBS) is a fundamental effect that can limit the performance of high-brightness electron machines, yet it has so far been neglected in standard modelling of RF photoinjectors. Recent measurements at SwissFEL reveal that…
The energy distribution of an ultracold rubidium ion beam, which is intended to be used as the source for a focused ion beam instrument, is measured with a retarding field analyzer. The ions are created from a laser-cooled and compressed…
Laser wakefield acceleration, characterized by the extremely high electric field gradient exceeding 100GV/m, is regarded as a compact and cost affordable technology for the next generation of particle colliders and light sources. However,…
In this article, we report on the development of a time-of-flight based electron energy analyzer capable of measuring the 3-D momentum and energy distributions of very low energy (meV-scale) photoemitted electrons. This analyzer is capable…
Linear collider designs foresee some bends of about 5-10 mrad. The spin precession angle of one TeV electrons on 10 mrad bend is 23.2 rad and it changes proportional to the energy. Measurement of the spin direction using Compton scattering…
As compared to electron storage rings, one advantage of recirculating linear accelerators is that the beam properties at target are no longer dominated by the equilibrium between quantum radiative diffusion and radiation damping because new…
The problem of electrons energy spread in the linear back Compton scattering process has been considered in the paper. The adjoint kinetic equation for the electrons passing through a laser flash has been obtained and used to get the…
To measure the energy spread of a energy electron beam up to $5 GeV$ in a single shoot measurement the possible applications of an existing magnet as spectrometer has been discussed. For distinguishing the energy resolution and an optimal…
Using scanning gate microscopy (SGM), we probe the scattering between a beam of electrons and a two-dimensional electron gas (2DEG) as a function of the beam's injection energy, and distance from the injection point. At low injection…
An enhanced ionization injection scheme using a tightly focused laser pulse with intensity near the ionization potential to trigger the injection process in a mismatched pre-plasma channel has been proposed and examined via…
The NLC extraction line provides a secondary focal point with a low beta function and 2 cm dispersion which can be used for measurement of the beam energy spectrum. In this study, tracking simulations were performed to transport the 0.5 TeV…
The detection of inelastically scattered soft X-rays with high energy resolution usually requires large grating spectrometers. Recently, photoelectron spectrometry for analysis of X-rays (PAX) has been rediscovered for modern spectroscopy…
Analyzing powers of pion-proton elastic scattering have been measured at PSI with the Low Energy Pion Spectrometer LEPS as well as a novel polarized scintillator target. Angular distributions between 40 and 120 deg (c.m.) were taken at…
A high-energy photon polarimeter for astrophysics studies in the energy range from 10 MeV to 800 MeV is considered. The proposed concept uses a stack of silicon micro-strip detectors where they play the roles of both a converter and a…
The luminosity distribution in the effective $\gamma\gamma$ mass at photon collider has usually two peaks which are well separated: high energy peak with mean energy spread 5-7% and wide low energy peak.The low energy peak depends strongly…