Related papers: Scattering Loss in Precision Metrology due to Mirr…
Reducing optical losses is crucial for reducing quantum noise in gravitational-wave detectors. Losses are the main source of degradation of the squeezed vacuum. Frequency dependent squeezing obtained via a filter cavity is currently used to…
The DECi-hertz Interferometer Gravitational wave Observatory (DECIGO) is designed to detect gravitational waves at frequencies between 0.1 and 10 Hz. In this frequency band, one of the most important science targets is the detection of…
In laser gravitational waves detectors optical loss restricts sensitivity. We discuss polarization scattering as one more possible mechanism of optical losses. Circulated inside interferometer light is polarized and after reflection its…
The sensitivity of the gravitational-wave detector KAGRA, presently under construction, will be limited by quantum noise in a large fraction of its spectrum. The most promising technique to increase the detector sensitivity is the injection…
Long-storage-time Fabry-Perot cavities are a core component of many precision measurement experiments. Optical loss in such cavities is a critical parameter in determining their performance; however, it is very difficult to determine a…
We describe an optical simulation program that models a complete, coupled-cavity interferometer like those used by the Laser Interferometer Gravitational-Wave Observatory (LIGO) Project. A wide variety of interferometer deformations can be…
The space-based gravitational wave detector DECIGO is designed to observe primordial gravitational waves with 1,000 km Fabry-Perot cavities. Its sensitivity is limited by quantum noise, and although squeezing can suppress it, its…
The topic of this thesis is the theoretical analysis of the optomechanical coupling effects in a high-finesse optical cavity, and the experimental realization of such a device. Radiation pressure exerted by light limits the sensitivity of…
Increasing the laser power is essential to improve the sensitivity of interferometric gravitational wave detectors. However, optomechanical parametric instabilities can set a limit to that power. It is of major importance to understand and…
A new generation of gravitational wave detectors is currently being designed with the likely use of a different laser wavelength compared to current instruments. The estimation of the optical losses for this new wavelength is particularly…
Quantum optical sensors are ubiquitous in various fields of research, from biological or medical sensors to large-scale experiments searching for dark matter or gravitational waves. Gravitational-wave detectors have been very successful in…
Optical cavities to filter squeezed light for quantum noise reduction require optics with very low scattering losses. We report on measured light scattering from two super-polished fused silica optics before and after applying…
The sensitivity in interferometric measurements such as gravitational-wave detectors is ultimately limited by quantum noise of light. We discuss the use of feedback mechanisms to reduce the quantum effects of radiation pressure. Recent…
We describe a setup based on Michelson interferometry for coherent measurements of the backscattered light from a low roughness optical surface under test. Special data processing was developed for the extraction of the useful signal from…
Calibration of the Advanced LIGO detectors is the quantification of the detectors' response to gravitational waves. Gravitational waves incident on the detectors cause phase shifts in the interferometer laser light which are read out as…
The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point…
The intracavity topologies of laser gravitational-wave detectors are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). The most challenging element of the intracavity…
A cavity ringdown system for probing the spatial variation of optical loss across high-reflectivity mirrors is described. This system is employed to examine substrate-transferred crystalline supermirrors and quantify the effect of…
Current laser-interferometric gravitational wave detectors suffer from a fundamental limit to their precision due to the displacement noise of optical elements contributed by various sources. Several schemes for Displacement-Noise Free…
A novel approach for measuring wavefunction collapse is proposed which, unlike interferometric measurements, is not affected by decoherence. A mirror of a Michelson interferometer is transferred into a quantum superposition, where the decay…