Related papers: Characterization of a Diode Dosimeter for UHDR FLA…

200 papers

Radiotherapy is part of the treatment of over 50% of cancer patients. Its efficacy is limited by the radiotoxicity to the healthy tissue. FLASH-RT is based on the biological effect that ultra-high dose rates (UHDR) and very short treatment…

While spatial dose conformity delivered to a target volume has been pushed to its practical limits with advanced treatment planning and delivery, investigations in novel temporal dose delivery are unfolding new mechanisms. Recent advances…

Purpose: Commercial UHDR platforms deliver Ultra-High Dose Rate (UHDR) doses at discrete combinations of pulse parameters including pulse width (PW), pulse repetition frequency (PRF) and number of pulses (N), which dictate unique…

First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The…

Background: In vivo dosimetry is essential for treatment verification in modern radiotherapy, but existing techniques are limited by spatiotemporal resolution and performance on non-uniform anatomy. Scintillation imaging dosimetry shows…

FLASH is a new treatment modality that requires optimization of dose, dose rate, and LET. Here we validate these three quantities under FLASH conditions, which includes the quantum uncertainty in the time-dependent instantaneous dose rate…

The aim of this study was to optimize the design and performance of parallel plate ion chambers for use in ultra-high dose rate (UHDR) dosimetry applications, and evaluate their potential as reference class chambers for calibration…

We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…

Instrumentation and Methods for Astrophysics · Physics 2023-12-19 Takahiro Minami , Miho Katsuragawa , Shunsaku Nagasawa , Shin'ichiro Takeda , Shin Watanabe , Yutaka Tsuzuki , Tadayuki Takahashi

Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy…

Medical Physics · Physics 2021-01-27 Haydee M. Linares Rosales , Louis Archambault , Sam Beddar , Luc Beaulieu

Objective: In this study, a fast imaging technique was developed for the first in vivo Cherenkov emission imaging from an ultra-high dose rate (UHDR) electron beam source at single pulse (360 Hz) submillimeter resolution. Approach: A CMOS…

Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents…

Instrumentation and Detectors · Physics 2021-12-08 Paolo Tancioni , Ulisse Gendotti

This study introduces the HYPERSCINT research platform, the first commercially available scintillation dosimetry platform capable of multi-point dosimetry through the hyperspectral approach. Optic and dosimetric performances of the system…

Instrumentation and Detectors · Physics 2021-04-19 Emilie Jean , Francois Therriault-Proulx , Luc Beaulieu

Ultrafast electron diffraction (UED) is a technique in which short-pulse electron beams can probe the femtosecond-scale evolution of atomic structure in matter driven far from equilibrium. As an accelerator physics challenge, UED imposes…

Purpose: For more than a decade that plastic optical fiber based dosimeters have been developed for medical applications. The feasibility of dosimeters using optical fibers that are almost Cherenkov light free has been demonstrated in some…

Medical Physics · Physics 2011-09-30 Florbela Rêgo , Luis Peralta , Maria da Conceição Abreu

This work investigates the dose-response curves of GAFCHROMIC EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron…

Objective: While FLASH radiotherapy is recognized for short-term normal tissue sparing, its durability in late-responding organs remains uncertain, limiting clinical adoption. With its clinical importance and steep dose-response, the spinal…

Purpose: HDR brachytherapy is a widely adopted modality for cancer treatment. However, it is not free from error and uncertainty. In-vivo dosimetry (IVD) is the only technique that can confirm correct dose delivery. This study details and…

Medical Physics · Physics 2025-12-10 Chahrazed Ghannoudi , Marie-Claude Lavallee , Benjamin Cote , Luc Beaulieu

In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…

Instrumentation and Detectors · Physics 2018-05-09 K. Mahata , A. Shrivastava , J. A. Gore , S. K. Pandit , V. V. Parkar , K. Ramachandran , A. Kumar , S. Gupta , P. Patale

Purpose: Highlight the distinctions, both in terms of concept and numerical values, of the various definitions that can be established for the dose rate in PBS proton therapy. Methods: In an in silico study, five definitions of the dose…

Medical Physics · Physics 2023-07-17 Sylvain Deffet , Valentin Hamaide , Edmond Sterpin