Related papers: High impedance TES bolometers for EDELWEISS
The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and…
We report on the development of commercially fabricated multi-chroic antenna coupled Transition Edge Sensor (TES) bolometer arrays for Cosmic Microwave Background (CMB) polarimetry experiments. The orders of magnitude increase in detector…
Large arrays of superconducting transition-edge sensor (TES) microcalorimeters are becoming the key technology for future space-based X-ray observatories and ground-based experiments in the fields of astrophysics, laboratory astrophysics,…
Since the invention of the bolometer, its main design principles relied on efficient light absorption into a low-heat-capacity material and its exceptional thermal isolation from the environment. While the reduced thermal coupling to its…
To improve both scalability and noise-filtering capability of a Transition-Edge Sensor (TES), a new concept of a thin-film detector is suggested, which is based on embedding a microbridge TES into a high-Q planar GHz range resonator weakly…
The High-Acceptance DiElectron Spectrometer (HADES) at GSI Darmstadt consists of a 6-coil toroidal magnet centered on the beam axis and six identical detection sections located between the coils and covering polar angles between $18^\circ$…
AlMn alloy flms are widely fabricated into superconducting transition edge sensors (TESs) for the detection of cosmic microwave background radiation. However, the application in X-ray or gamma-ray detection based on AlMn TES is rarely…
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a…
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…
We report a polarization-induced 2D electron gas (2DEG) at an epitaxial AlBN/GaN heterojunction grown on a SiC substrate. Using this 2DEG in a long conducting channel, we realize ultra-thin barrier AlBN/GaN high electron mobility…
We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave…
Following a recently manifested guide of how to team up infrared transparency and high electrical conductivity within semimetal materials [C. Cui $et$ $al.$ Prog. Mater. Sci. 2023, 136, 101112], we evaluate an applicability of the calcium…
This study investigates new technology for enhancing the sensitivity of low-mass dark matter detection by analyzing charge transport in a p-type germanium detector at 5.2 K. To achieve low-threshold detectors, precise calculations of the…
We present ultra-thin silicon membrane thermocouple bolometers suitable for fast and sensitive detection of low levels of thermal power and infrared radiation at room temperature. The devices are based on 40 nm-thick strain tuned single…
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…
In this letter, we present the performance of a $100~\mu\mathrm{m}\times 400~\mu\mathrm{m} \times 40~\mathrm{nm}$ tungsten (W) Transition-Edge Sensor (TES) with a critical temperature of 40 mK. This device has a measured noise equivalent…
We describe a new high-purity germanium (HPGe) detector setup for low-background {\gamma}-ray spectrometry. The GeMSE facility (Germanium Material and meteorite Screening Experiment) is dedicated to material screening for rare event…
We report a photon number resolving detector using two-dimensional electron gas (2DEG) based transistors. When the photon pulses impinge on the absorption region, the generated phonons dissipate ballistically in the 2DEG toward the trench…
Superconducting hot-electron bolometers are presently the best performing mixing devices for the frequency range beyond 1.2 THz, where good quality superconductor-insulator-superconductor (SIS) devices do not exist. Their physical…
The composition of dark matter is one of the puzzling topics in astrophysics. To address this issue, several experiments searching for the existence of axions have been designed, built and realized in the last twenty years. Among all the…