English
Related papers

Related papers: Size-adjustable Ring-shape Photoacoustic Tomograph…

200 papers

Photo-acoustic tomography (PAT) aims to leverage the photo-acoustic coupling between optical absorption of light sources and ultrasound (US) emission to obtain high contrast reconstructions of optical parameters with the high resolution of…

Analysis of PDEs · Mathematics 2016-09-21 Guillaume Bal , Amir Moradifam

Photoacoustic tomography (PAT) offers high optical contrast with acoustic imaging depth, making it essential for biomedical applications. While many all-optical systems have been developed to address limitations of ultrasound transducers,…

Optics · Physics 2024-10-11 Taeil Yoon , Hakseok Ko , Jeongmyo Im , Euiheon Chung , Wonshik Choi , Byeong Ha Lee

Purpose: Photoacoustic tomography (PAT) is a novel imaging technique that can spatially resolve both morphological and functional tissue properties, such as the vessel topology and tissue oxygenation. While this capacity makes PAT a…

Photoacoustic tomography (PAT) is a newly developed medical imaging modality, which combines the advantages of pure optical imaging and ultrasound imaging, owning both high optical contrast and deep penetration depth. Very recently, PAT is…

Medical Physics · Physics 2021-09-21 Tengbo Lyu , Jiadong Zhang , Zijian Gao , Changchun Yang , Feng Gao , Fei Gao

Photoacoustic tomography (PAT) is a rapidly-evolving medical imaging modality that combines optical absorption contrast with ultrasound imaging depth. One challenge in PAT is image reconstruction with inadequate acoustic signals due to…

Photoacoustic tomography (PAT) is a non-invasive imaging modality that requires recovering the initial data of the wave equation from certain measurements of the solution outside the object. In the standard PAT measurement setup, the used…

Analysis of PDEs · Mathematics 2021-12-07 Linh V. Nguyen , Markus Haltmeier , Richard Kowar , Ngoc Do

Imaging the human body's morphological and angiographic information is essential for diagnosing, monitoring, and treating medical conditions. Ultrasonography performs the morphological assessment of the soft tissue based on acoustic…

Photoacoustic tomography (PAT) is an emerging technology for biomedical imaging that combines the superiorities of high optical contrast and acoustic penetration. In the PAT system, more photoacoustic (PA) signals are preferred to be…

Instrumentation and Detectors · Physics 2020-12-09 Daohuai Jiang , Hengrong Lan , Yiyun Wang , Feng Gao , Fei Gao

Photoacoustic Tomography (PAT) is an emerging biomedical "imaging from coupled physics" technique, in which the image contrast is due to optical absorption, but the information is carried to the surface of the tissue as ultrasound pulses.…

Numerical Analysis · Mathematics 2016-11-03 Simon R. Arridge , Marta M. Betcke , Ben T. Cox , Felix Lucka , Brad E. Treeby

As an emerging medical diagnostic technology, photoacoustic imaging has been implemented for both preclinical and clinical applications. For clinical convenience, a handheld free scan photoacoustic tomography (PAT) system providing 3D…

Medical Physics · Physics 2022-03-18 Daohuai Jiang , Hongbo Chen , Yuting Shen , Yifan Zhang , Feng Gao , Rui Zheng , Fei Gao

Photoacoustic computed tomography (PACT) is emerging as a new technique for functional brain imaging, primarily due to its capabilities in label-free hemodynamic imaging. Despite its potential, the transcranial application of PACT has…

Multispectral photoacoustic tomography (PAT) is an imaging modality that utilizes the photoacoustic effect to achieve non-invasive and high-contrast imaging of internal tissues. However, the hardware cost and computational demand of a…

Image and Video Processing · Electrical Eng. & Systems 2024-04-11 Yutian Zhong , Xiaoming Zhang , Zongxin Mo , Shuangyang Zhang , Wufan Chen , Li Qi

Photoacoustic computed tomography (PACT) combines the optical contrast of optical imaging and the penetrability of sonography. In this work, we develop a novel PACT system to provide real-time imaging, which is achieved by a 120-elements…

Image and Video Processing · Electrical Eng. & Systems 2021-05-10 Hengrong Lan , Daohuai Jiang , Feng Gao , Fei Gao

The photoacoustic tomography (PAT) is a hybrid modality that combines the optics and acoustics to obtain high resolution and high contrast imaging of heterogeneous media. In this work, our objective is to study the inverse problem in the…

Numerical Analysis · Mathematics 2021-05-26 Hongkai Zhao , Yimin Zhong

In photoacoustic tomography (PAT), a hybrid imaging modality that is based on the acoustic detection of optical absorption from biological tissue exposed to a pulsed laser, a short pulse laser generates an initial pressure proportional to…

Numerical Analysis · Mathematics 2026-03-27 Sunghwan Moon , Anwesa Dey , Souvik Roy

Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging technique that holds great promise for biomedical imaging. PACT is a hybrid imaging method that can exploit the strong endogenous…

Medical Physics · Physics 2019-05-13 Joemini Poudel , Yang Lou , Mark A. Anastasio

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging…

Medical Physics · Physics 2016-11-15 Qiwei Sheng , Kun Wang , Thomas P. Matthews , Jun Xia , Liren Zhu , Lihong V. Wang , Mark A. Anastasio

Photoacoustic Computed Tomography (PACT) is a major configuration of photoacoustic imaging, a hybrid noninvasive modality for both functional and molecular imaging. PACT has rapidly gained importance in the field of biomedical imaging due…

Photoacoustic tomography (PAT) enables non-invasive cross-sectional imaging of biological tissues, but it fails to map the spatial variation of speed-of-sound (SOS) within tissues. While SOS is intimately linked to density and elastic…

Medical Physics · Physics 2024-08-27 Yang Wang , Danni Wang , Liting Zhong , Yi Zhou , Qing Wang , Wufan Chen , Li Qi

Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in…

Numerical Analysis · Mathematics 2016-12-21 Simon Arridge , Paul Beard , Marta Betcke , Ben Cox , Nam Huynh , Felix Lucka , Olumide Ogunlade , Edward Zhang
‹ Prev 1 2 3 10 Next ›