Related papers: Swap-test interferometry with biased ancilla noise
Achieving the ultimate quantum precision in the estimation of multiple physical parameters simultaneously is a challenge in quantum metrology due to fundamental limitations and experimental challenges in harnessing the necessary quantum…
The canonical Mach-Zehnder interferometer fed with a coherent state and a squeezed-vacuum state of equal intensities is theoretically predicted to achieve Heisenberg scaling in phase sensitivity. However, this ultimate performance is…
We show that the phase sensitivity $\Delta \theta$ of a Mach-Zehnder interferometer fed by a coherent state in one input port and squeezed-vacuum in the other one is i) independent from the true value of the phase shift and ii) can reach…
The best performance of a Mach-Zehnder interferometer is achieved with the input state |N_T/2 + 1>|N_T/2-1 > + |N_T/2 - 1>|N_T/2+1>, being N_T the total number of atoms/photons. This gives: i) a phase-shift error confidence C_{68%}=2.67/N_T…
We study Fock state interferometry, consisting of a Mach-Zehnder Interferometer with two Fock state inputs and photon-number-resolved detection at the two outputs. We show that it allows discrimination of a discrete number of apriori-known…
Phase measurement using a lossless Mach-Zehnder interferometer with certain entangled $N$-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are…
The super-sensitivity attained in quantum phase estimation is known to be compromised in the presence of decoherence. This is particularly patent at blind spots -- phase values at which sensitivity is totally lost. One remedy is to use a…
Interferometry is a widely-used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example in a Mach-Zehnder interferometer (MZI), is to use…
The Mach-Zehnder interferometer is a fundamental tool for measuring phase shifts between two light paths, serving as a crucial prototype for achieving high-precision measurements in various scientific and technological applications. In this…
We study a Mach-Zehnder interferometer fed by a coherent state in one input port and vacuum in the other. We explore a Bayesian phase estimation strategy to demonstrate that it is possible to achieve the standard quantum limit independently…
The phase resolution of interferometers is limited by the so-called Heisenberg limit, which states that the optimum phase sensitivity is inversely proportional to the number of interfering particles N, a 1/sqrt{N} improvement over the…
We derive, and experimentally demonstrate, an interferometric scheme for unambiguous phase estimation with precision scaling at the Heisenberg limit that does not require adaptive measurements. That is, with no prior knowledge of the phase,…
We quantitatively investigate phase measurement in a Mach-Zehnder interferometer (MZI), which is injected with a weak coherent and a squeezed vacuum generated from a spontaneous parametric down-conversion. The measured three-photon…
For a generic interferometer, the conditional probability density distribution, $p(\phi|m)$, for the phase $\phi$ given measurement outcome $m$, will generally have multiple peaks. Therefore, the phase sensitivity of an interferometer…
Two mode squeezed states can be used to achieve Heisenberg limit scaling in interferometry: a phase shift of $\delta \phi \approx 2.76 / < N >$ can be resolved. The proposed scheme relies on balanced homodyne detection and can be…
We investigate the phase sensitivity of a Mach-Zehnder interferometer using a special class of generalized coherent states constructed from generalized Heisenberg and deformed $su(1,1)$ algebras. These states, derived from a perturbed…
We theoretically analyze a Mach-Zehnder interferometer with trapped condensates, and find that it is surprisingly stable against the nonlinearity induced by inter-particle interactions. The phase sensitivity, which we study for number…
The ultimate precision of phase estimation is limited by the Heisenberg scaling $\Delta\phi_0 = K/N$, where $K\sim1$ is a numerical prefactor and $N$ is the mean number of photons interacting with the phase shifting object(s). However,…
Many works have stated that nonlinear interactions can improve phase sensitivity beyond the Heisenberg limit scaling of $1/N$ with $N$ being the mean photon number. This raises some open questions---among them the conclusive sensitivity…
Phase-shifting interferometry is one of the optical measurement techniques that improves accuracy and resolution by incorporating a controlled phase shift into conventional optical interferometry. In this study, a four-step phase-shifting…