English
Related papers

Related papers: Longevity Study on the CMS Resistive Plate Chamber…

200 papers

The LHC detectors are well into their construction phase. The LHC schedule shows first beam to ATLAS and CMS in 2007. Because the LHC accelerator has begun to plan for a ten fold increase in LHC design luminosity (the SLHC or super LHC) it…

High Energy Physics - Experiment · Physics 2009-11-10 Dan Green

As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the…

Instrumentation and Detectors · Physics 2020-06-02 Sabino Meola

The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for…

Instrumentation and Detectors · Physics 2018-07-01 Florian Pitters

A novel type of resistive plate chamber, based on diamond-like carbon (DLC) electrodes is under development for background identification in the MEG II experiment. The DLC-RPC is required to have a radiation hardness to mass irradiation…

Instrumentation and Detectors · Physics 2024-07-09 Masato Takahashi , Sei Ban , Weiyuan Li , Atsuhiko Ochi , Wataru Ootani , Atsushi Oya , Hiromu Suzuki , Kensuke Yamamoto

A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold…

The CMS detector at the LHC requires a major upgrade to cope with the higher instantaneous luminosity and the elevated radiation levels. The active media of the forward backing hadron calorimeters is projected to be radiation-hard, high…

Instrumentation and Detectors · Physics 2015-10-30 Emrah Tiras

The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5 - 7.5 $\times$ 10$^{34}$cm$^{-2}$ s$^{-1}$. This represents a more than 3-4 fold…

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an…

Instrumentation and Detectors · Physics 2015-05-15 Simon Spannagel

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

The challenging High Luminosity LHC (HL-LHC) beam requirements will lead in the future to unprecedented beam parameters along the LHC injector chain. In the SPS accelerator these requests translate into about a factor two higher intensity…

Resistive Plate Chambers have a very important role for muon triggering both in the barrel and in the endcap regions of the CMS experiment at the Large Hadron Collider (LHC). In order to optimize their performance, it is of primary…

Instrumentation and Detectors · Physics 2020-06-03 W. Elmetenawee

The CMS experiment will include a pixel detector for pattern recognition and vertexing. It will consist of three barrel layers and two endcaps on each side, providing three space-points up to a pseudoraditity of 2.1. Taking into account the…

Instrumentation and Detectors · Physics 2009-11-11 R. Horisberger , D. Kotlinski , T. Rohe

Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to…

Long-lived charged particles are predicted by various theories beyond the Standard Model, leading to unique signatures that could reveal new physics. At the LHC, the CMS detector enables searches for these massive particles, identifiable by…

High Energy Physics - Experiment · Physics 2025-11-06 Tamas Almos Vami

The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…

High Energy Physics - Experiment · Physics 2025-02-11 Clara Lasaosa

The Large Hadron Collider is the world's largest and highest center-of-mass energy particle accelerator. During the Phase I operation it is expected that the LHC operated at a centre-of-mass energy of 13 TeV will deliver to the CMS…

High Energy Physics - Experiment · Physics 2018-08-30 Petr Mandrik

The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different…

Instrumentation and Detectors · Physics 2015-05-20 R. S. Schmidt , A. J. Bell , E. Castro , R. Hall-Wilton , M. Hempel , W. Lange , W. Lohmann , S. Müller , V. Ryjov , D. Stickland , R. Walsh

We present the current status of the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle (LLP) detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA40 is a…

The Phase II upgrade of the ATLAS Muon Spectrometer will involve the installation of approximately 1000 next-generation Resistive Plate Chamber (RPC) singlets. This upgrade aims to enhance detector coverage, increase hit efficiency, and…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah
‹ Prev 1 4 5 6 7 8 10 Next ›