English
Related papers

Related papers: A Compact High-Resolution Muon Spectrometer Using …

200 papers

Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could…

Instrumentation and Detectors · Physics 2016-11-17 K. Gnanvo , B. Benson , W. Bittner , F. Costa , L. Grasso , M. Hohlmann , J. B. Locke , S. Martoiu , H. Muller , M. Staib , A. Tarazona , J. Toledo

The presence of muons in air-showers initiated by cosmic ray protons and nuclei is well established as a powerful tool to separate such showers from those initiated by gamma-rays. However, so far this approach has been fully exploited only…

High Energy Astrophysical Phenomena · Physics 2021-09-10 Laura Olivera-Nieto , Alison M. W. Mitchell , Konrad Bernlöhr , James A. Hinton

Muon scattering tomography (MST) is a non-destructive technique to image various materials by utilizing cosmic ray muons as probes. A typical MST system with a two-fold track detectors is particularly effective in detecting high-$Z$…

Instrumentation and Detectors · Physics 2023-08-22 Jiahui Chen , Huiling Li , Yiyue Li , Pingcheng Liu

Recently, cosmic ray muons have been considered as a potential high energy radiation probe for monitoring and interrogation of dense, well-shielded special nuclear materials (SNM). Due to their high-penetrative nature, cosmic ray muons can…

Instrumentation and Detectors · Physics 2022-02-08 Junghyun Bae , Stylianos Chatzidakis

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger

A magnetic detector such as MINOS which is measuring the sign of muons has to deal with issues of bending, which depend on the magnetic field configuration, and multiple scattering, which depends on the amount of material which is…

Instrumentation and Detectors · Physics 2007-06-06 Maury Goodman

For decades, the application of muon tomography to spent nuclear fuel (SNF) cask imaging has been theoretically evaluated and experimentally verified by many research groups around the world, including Los Alamos National Laboratory in the…

Instrumentation and Detectors · Physics 2023-05-01 JungHyun Bae , Rose Montgomery , Stylianos Chatzidakis

Recent applications of cosmic-ray muons require accurate modeling of their flux at low-energy. However, no measurement has been reported below 400 MeV. Therefore, we developed a full-absorption muon energy spectrometer to obtain energy…

Applied Physics · Physics 2022-08-24 Hikaru Sato , Tadahiro Kin , Andrea Giammanco

We present a momentum measurement method based on multiple Coulomb scattering (MCS) in the FASER$\nu$ emulsion detector. The measurement of charged-particle momenta is essential for studying neutrino interactions in the TeV energy range at…

Instrumentation and Detectors · Physics 2026-02-20 FASER Collaboration , Roshan Mammen Abraham , Xiaocong Ai , Saul Alonso Monsalve , John Anders , Emma Kate Anderson , Claire Antel , Akitaka Ariga , Tomoko Ariga , Jeremy Atkinson , Florian U. Bernlochner , Tobias Boeckh , Eliot Bornand , Jamie Boyd , Lydia Brenner , Angela Burger , Franck Cadoux , Roberto Cardella , David W. Casper , Charlotte Cavanagh , Shiyang Chen , Xin Chen , Xing Cheng , Kohei Chinone , Dhruv Chouhan , Andrea Coccaro , Stephane Débieux , Ansh Desai , Sergey Dmitrievsky , Radu Dobre , Monica D'Onofrio , Sinead Eley , Yannick Favre , Jonathan L. Feng , Carlo Alberto Fenoglio , Didier Ferrere , Max Fieg , Wissal Filali , Elena Firu , Haruhi Fujimori , Edward Galantay , Ali Garabaglu , Stephen Gibson , Sergio Gonzalez-Sevilla , Yuri Gornushkin , Yotam Granov , Jinjing Gu , Carl Gwilliam , Elie Hammou , Daiki Hayakawa , Michael Holzbock , Shih-Chieh Hsu , Zhen Hu , Giuseppe Iacobucci , Tomohiro Inada , Luca Iodice , Sune Jakobsen , Cesar Jesus-Valls , Arash Jofrehei , Hans Joos , Enrique Kajomovitz , Takumi Kanai , Hiroaki Kawahara , Alex Keyken , Felix Kling , Daniela Köck , Pantelis Kontaxakis , Jelle Koorn , Umut Kose , Peter Krack , Susanne Kuehn , Thanushan Kugathasan , Sebastian Laudage , Lorne Levinson , Botao Li , Jinfeng Liu , Yi Liu , Margaret S. Lutz , Jack MacDonald , Joern Mahlstedt , Toni Mäkelä , Anna Mascellani , Lawson McCoy , Josh McFayden , Andrea Pizarro Medina , Théo Moretti , Keiko Moriyama , Toshiyuki Nakano , Laurie Nevay , Motoya Nonaka , Yuma Ohara , Ken Ohashi , Kazuaki Okui , Hidetoshi Otono , Lorenzo Paolozzi , Annabelle Parry , Pawan Pawan , Brian Petersen , Titi Preda , Markus Prim , Junkai Qin , Michaela Queitsch-Maitland , Juan Rojo , Hiroki Rokujo , André Rubbia , Osamu Sato , Paola Scampoli , Kristof Schmieden , Matthias Schott , Cristiano Sebastiani , Anna Sfyrla , Davide Sgalaberna , Mansoora Shamim , Yosuke Takubo , Noshin Tarannum , Simon Thor , Eric Torrence , Oscar Ivan Valdes Martinez , Svetlana Vasina , Benedikt Vormwald , Chi Wang , Yuxiao Wang , Eli Welch , Aaron White , Monika Wielers , Benjamin James Wilson , Yue Xu , Heng Yang , Lekai Yao , Daichi Yoshikawa , Stefano Zambito , Shunliang Zhang , Yuxuan Zhang , Xingyu Zhao , Zijian Zhao

This paper presents several approaches to deal with the problem of identifying muons in a water Cherenkov detector with a reduced water volume and 4 PMTs. Different perspectives of information representation are used and new features are…

Instrumentation and Detectors · Physics 2021-01-29 B. S. González , R. Conceição , M. Pimenta , B. Tomé , A. Guillén

Beam diagnostics are crucial for smooth accelerator operations. Many techniques rely on instrumentation in which the beam properties are significantly affected by the measurement. Novel approaches aim to use Cherenkov Diffraction Radiation…

We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very…

Large underwater telescopes have been proposed as a challenging method to measure high energy neutrinos from astrophysical objects. In recent years, The Antares collaboration has designed and realized the first detector of this type in the…

Instrumentation and Methods for Astrophysics · Physics 2026-05-21 K. Gracheva , M. Anghinolfi , V. Kulikovskiy , E. Shirokov , Y. Yakovenko

We present an improved technique for estimating a muon's energy by measuring the deflections along its path inside the MicroBooNE detector from multiple Coulomb scattering (MCS). This approach implements several innovations that better…

High Energy Physics - Experiment · Physics 2026-05-06 MicroBooNE Collaboration , P. Abratenko , D. Andrade Aldana , J. Asaadi , A. Ashkenazi , S. Balasubramanian , B. Baller , A. Barnard , G. Barr , D. Barrow , J. Barrow , V. Basque , J. Bateman , B. Behera , O. Benevides Rodrigues , S. Berkman , A. Bhat , M. Bhattacharya , V. Bhelande , A. Binau , M. Bishai , A. Blake , B. Bogart , T. Bolton , M. B. Brunetti , L. Camilleri , D. Caratelli , F. Cavanna , G. Cerati , A. Chappell , Y. Chen , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , R. Cross , M. Del Tutto , S. R. Dennis , P. Detje , R. Diurba , Z. Djurcic , K. Duffy , S. Dytman , B. Eberly , P. Englezos , A. Ereditato , J. J. Evans , C. Fang , B. T. Fleming , W. Foreman , D. Franco , A. P. Furmanski , F. Gao , D. Garcia Gamez , S. Gardiner , G. Ge , S. Gollapinni , E. Gramellini , P. Green , H. Greenlee , L. Gu , W. Gu , R. Guenette , L. Hagaman , M. D. Handley , M. Harrison , S. Hawkins , A. Hergenhan , O. Hen , C. Hilgenberg , G. A. Horton-Smith , A. Hussain , B. Irwin , M. S. Ismail , C. James , X. Ji , J. H. Jo , R. A. Johnson , A. Johnson , D. Kalra , G. Karagiorgi , A. Kelly , W. Ketchum , M. Kirby , T. Kobilarcik , K. Kumar , N. Lane , J. -Y. Li , Y. Li , K. Lin , B. R. Littlejohn , L. Liu , S. Liu , W. C. Louis , X. Luo , T. Mahmud , N. Majeed , C. Mariani , J. Marshall , M. G. Manuel Alves , D. A. Martinez Caicedo , F. Martinez Lopez , S. Martynenko , A. Mastbaum , I. Mawby , N. McConkey , B. McConnell , L. Mellet , J. Mendez , J. Micallef , A. Mogan , T. Mohayai , M. Mooney , A. F. Moor , C. D. Moore , L. Mora Lepin , M. A. Hernandez Morquecho , M. M. Moudgalya , S. Mulleriababu , D. Naples , A. Navrer Agasson , N. Nayak , M. Nebot-Guinot , C. Nguyen , L. Nguyen , J. Nowak , N. Oza , O. Palamara , N. Pallat , V. Paolone , A. Papadopoulou , V. Papavassiliou , H. B. Parkinson , S. F. Pate , N. Patel , Z. Pavlovic , E. Piasetzky , K. Pletcher , I. Pophale , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , M. Reggiani-Guzzo , J. Rodriguez Rondon , M. Rosenberg , M. Ross-Lonergan , I. Safa , C. Sauer , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Shi , L. Silva , E. L. Snider , S. Soldner-Rembold , J. Spitz , M. Stancari , J. St. John , T. Strauss , A. M. Szelc , N. Taniuchi , K. Terao , C. Thorpe , D. Torbunov , D. Totani , M. Toups , A. Trettin , Y. -T. Tsai , J. Tyler , M. A. Uchida , T. Usher , B. Viren , J. Wang , L. Wang , M. Weber , H. Wei , A. J. White , S. Wolbers , T. Wongjirad , K. Wresilo , W. Wu , E. Yandel , T. Yang , L. E. Yates , H. W. Yu , G. P. Zeller , J. Zennamo , C. Zhang , Y. Zhang

The ATLAS muon spectrometer is designed to measure muon momenta with a resolution of 4% @ 100 GeV/c rising to 10% @ 1 TeV/c track momentum. The spectrometer consists of precision tracking and trigger chambers embedded in a 2T magnetic field…

Instrumentation and Detectors · Physics 2019-08-13 E. Diehl

This work presents the measurements of the cosmic muon charge ratio as a function of full azimuthal angle and momentum within the range of 0.8 to 3.0 GeV/c, using the mini-ICAL detector. The detector, comprising 10 layers of RPCs, has…

High Energy Physics - Experiment · Physics 2024-10-10 Raj Shah , J. M. John , Suryanarayan Mondal , S. Pethuraj , G. Majumder , P. Shukla

Several methods can be used to perform statistical inference of primary composition of cosmic rays measured with water Cerenkov detectors as those in use at the Pierre Auger Southern Observatory. In the present work we assess the impact of…

A ring-imaging \v{C}erenkov counter read out by a 100-channel PMT of active area 10$\times$10 cm$^2$ was operated successfully in a test beam at the BNL AGS with several radiator gases, including the heavy fluorocarbon C$_4$F$_{10}$. Ring…

High Energy Physics - Experiment · Physics 2010-11-01 R. Debbe , S. Gushue , B. Moskowitz , J. Norris , J. Olness , F. Videbaek