Related papers: Scalable Learning for Optimal Load Shedding Under …
Prompt and effective corrective actions in response to unexpected contingencies are crucial for improving power system resilience and preventing cascading blackouts. The optimal load shedding (OLS) accounting for network limits has the…
Emergency control, typically such as under-voltage load shedding (UVLS), is broadly used to grapple with low voltage and voltage instability issues in practical power systems under contingencies. However, existing emergency control schemes…
Load shedding has been one of the most widely used and effective emergency control approaches against voltage instability. With increased uncertainties and rapidly changing operational conditions in power systems, existing methods have…
The paradigm shift in the electric power grid necessitates a revisit of existing control methods to ensure the grid's security and resilience. In particular, the increased uncertainties and rapidly changing operational conditions in power…
Solving for globally optimal line switching decisions in AC transmission grids can be intractability slow. Machine learning (ML) models, meanwhile, can be trained to predict near-optimal decisions at a fraction of the speed. Verifying the…
Load shedding is the last and most expensive control action against system collapse and blackout. Achievement of an efficient emergency control to stabilize the power system following severe disturbances, requires two key objectives. First,…
We consider the worst-case load-shedding problem in electric power networks where a number of transmission lines are to be taken out of service. The objective is to identify a pre-specified number of line outage that leads to the maximum…
Under frequency load shedding (UFLS) constitutes the very last resort for preventing total blackouts and cascading events. Fluctuating operating conditions and weak resilience of the future grid require UFLS strategies adapt to various…
Under voltage load shedding has been considered as a standard approach to recover the voltage stability of the electric power grid under emergency conditions, yet this scheme usually trips a massive amount of load inefficiently.…
High penetration of renewable resources results in a power system with lower inertia and higher frequency sensitivity to power imbalances. Such systems are becoming increasingly susceptible to frequency collapse during extreme disturbances.…
Underfrequency load shedding (UFLS) is a critical control strategy in power systems aimed at maintaining system stability and preventing blackouts during severe frequency drops. Traditional UFLS schemes often rely on predefined rules and…
Under voltage load shedding (UVLS) for power grid emergency control builds the last defensive perimeter to prevent cascade outages and blackouts in case of contingencies. This letter proposes a novel cooperative multi-agent deep…
This paper deals with the secure Optimal Transmission Switching (OTS) problem in situations where the TSO is forced to accept the risk that some contingencies may result in the de-energization of parts of the grid to avoid the violation of…
Optical neural networks (ONNs) have demonstrated record-breaking potential in high-performance neuromorphic computing due to their ultra-high execution speed and low energy consumption. However, current learning protocols fail to provide…
Operational Neural Networks (ONNs) have recently been proposed to address the well-known limitations and drawbacks of conventional Convolutional Neural Networks (CNNs) such as network homogeneity with the sole linear neuron model. ONNs are…
Power systems are increasingly operated in corrective rather than preventive security mode, which means that appropriate control actions must be taken immediately after a contingency has occurred. This paper proposes an online algorithm for…
Power system emergency control is generally regarded as the last safety net for grid security and resiliency. Existing emergency control schemes are usually designed off-line based on either the conceived "worst" case scenario or a few…
The adversarial worst-case load shedding (AWLS) problem is pivotal for identifying critical contingencies under line outages. It is naturally cast as a bilevel program: the upper level simulates an attacker determining worst-case line…
This paper has delved into the pressing need for intelligent emergency control in large-scale power systems, which are experiencing significant transformations and are operating closer to their limits with more uncertainties. Learning-based…
Neural networks (NNs) can achieved high performance in various fields such as computer vision, and natural language processing. However, deploying NNs in resource-constrained safety-critical systems has challenges due to uncertainty in the…