English
Related papers

Related papers: X-ray phase-sensitive microscope imaging with a gr…

200 papers

X-ray phase-contrast imaging has experienced rapid development over the last few decades, and in this technology, the phase modulation strategy of phase-stepping is used most widely to measure the sample's phase signal. However, because of…

Medical Physics · Physics 2017-12-06 Faiz Wali , Shenghao Wang , Huajie Han , Kun Gao , Zhao Wu , Peiping Zhu , Yangchao Tiana

Dark-field imaging based on grating interferometry is an emerging X-ray modality in medical imaging, which is particularly capable of providing complementary diagnostic information by visualizing the microstructural properties of lung…

Medical Physics · Physics 2026-05-29 Longchao Men , Peiyuan Guo , Jincheng Lu , Yan Xu , Hongxia Yin , Zhenchang Wang , Li Zhang , Zhentian Wang

In this paper, we describe the principle of a multi-aperture interferometer that uses a phase-shifting technique and is suitable for quick, snapshot imaging of astrophysical objects at extreme angular resolution through Fourier inversion. A…

Optics · Physics 2015-05-28 Francois Henault

Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated.…

We reported the usage of grating-based X-ray phase-contrast imaging in nondestructive testing of grating imperfections. It was found that electroplating flaws could be easily detected by conventional absorption signal, and in particular, we…

Instrumentation and Detectors · Physics 2018-04-27 Shenghao Wang , Can Zhang

Phase-sensitive coherent imaging exploits changes in the phases of backscattered light to observe tiny alterations of scattering structures or variations of the refractive index. But moving scatterers or a fluctuating refractive index…

Currently, dual-energy X-ray phase contrast imaging is usually conducted with an X-ray Talbot-Lau interferometer. However, in this system, the two adopted energy spectra have to be chosen carefully in order to match well with the phase…

Medical Physics · Physics 2019-11-22 Shenghao Wang , Guibin Zan , Qiuping Wang , Shijie Liu

X-ray phase-contrast imaging enhances soft tissue visualization by leveraging the phase shift of X-rays passing through materials. It permits to minimize radiation exposure due to high contrast, as well as high resolution imaging limited by…

Optics · Physics 2024-03-13 Emilie Pietersoone , Jean Michel Létang , Simon Rit , Max Langer

Dark-field contrast imaging with grating interferometers has proven to hold huge potential for numerous applications with X-rays and with neutrons conveying biology and medicine as well as engineering and magnetism, respectively. However, a…

Materials Science · Physics 2013-12-03 Markus Strobl

A device based on a three-block Fresnel zone plate interferometer is proposed for hard X-ray phase-contrast imaging. The device combines a low requirement for the coherence of the initial radiation (the interferometer operates in the…

Instrumentation and Detectors · Physics 2021-04-22 L. A. Haroutunyan

X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took…

Phase diffusion represents a crucial obstacle towards the implementation of high precision interferometric measurements and phase shift based communication channels. Here we present a nearly optimal interferometric scheme based on homodyne…

These tutorials introduce some basics of imaging with coherent X-rays, focusing on phase contrast. We consider the transport-of-intensity equation, as one particular method for X-ray phase contrast imaging among many, before passing on to…

Image and Video Processing · Electrical Eng. & Systems 2019-02-28 David M. Paganin , Daniele Pelliccia

We present a multi-aperture analyser set-up for performing X-ray phase contrast imaging in planar and three-dimensional modalities. A multi-slice representation of the sample is used to establish a quantitative relation between projection…

Instrumentation and Detectors · Physics 2017-06-21 M. Endrizzi , F. A. Vittoria , L. Rigon , D. Dreossi , A. Olivo

Diffraction gratings have been proposed as core optical elements in future laser-interferometric gravitational-wave detectors. In this paper we derive equations for the coupling between alignment noise and phase noise at diffraction…

General Relativity and Quantum Cosmology · Physics 2009-12-10 A. Freise , A. Bunkowski , R. Schnabel

A typical application for laser interferometers is a precision measurement of length changes that result in interferometric phase shifts. Such phase changes are typically predicted numerically, due to the com- plexity of the overlap…

Optics · Physics 2014-06-06 Gudrun Wanner , Gerhard Heinzel

When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. In- terference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made…

Cross-grating phase microscopy (CGM) is a quantitative phase microscopy technique based on the association of a 2-dimensional diffraction grating (cross-grating) and a regular camera sensor, separated by a millimetric distance. This simple…

Optics · Physics 2024-11-04 Baptiste Marthy , Guillaume Baffou

Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction.…

In coherent X-ray diffraction microscopy the diffraction pattern generated by a sample illuminated with coherent x-rays is recorded, and a computer algorithm recovers the unmeasured phases to synthesize an image. By avoiding the use of a…