Related papers: Study on NaI(Tl) crystal at -35 C for dark matter …
Direct detection experiments for light dark matter are making enormous leaps in reaching previously unexplored model space. Several recent proposals rely on collective excitations, where the experimental sensitivity is highly dependent on…
An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to $\alpha$-particles from 5…
Monochromatic neutron emissions from photonuclear sources $^{88}$Y/Be and $^{124}$Sb/Be are employed to obtain the response of pure (undoped) cesium iodide at 80 K. The use of a low-noise, high-quantum-efficiency avalanche photodiode in…
Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below $\sim3$…
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent…
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to…
The Neutrino Elastic-scattering Observation with NaI(Tl) experiment (NEON) aims to detect coherent elastic neutrino-nucleus scattering~(\cenns) in a NaI(Tl) crystal using reactor anti-electron neutrinos at the Hanbit nuclear power plant…
Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the…
Detection of low-energy nuclear recoil events plays a central role in searches for particle dark matter interactions with atomic matter and studies of coherent neutrino scatters. Precise nuclear recoil calibration data allow the responses…
A cryogenic detector system based on two 3.3 kg high-purity CsI crystals was developed and characterized at approximately 95 K. Each wedge-shaped crystal was coupled to dual-ended 3-inch photomultiplier tubes (PMTs) for scintillation…
We studied the temperature dependence of the light yield of the linear alkyl benzene (LAB)-based and mesitylene-based liquid scintillators. The light yield increases by 23% for both liquid scintillators when the temperature is lowered from…
Sodium iodide (NaI) is a widely used scintillator in direct dark matter searches. In particular, NaI-based cryogenic scintillating calorimeters have emerged as promising candidates, like in the COSINUS experiment, for testing the annually…
Non-proportional response of the scintillation yield of NaI:Tl was measured using highly monochromatic synchrotron irradiation ranging from 9 to 100 keV. Special attention is paid to the X-ray escape peaks. They provide us additional…
Thallium-doped sodium iodide (NaI(Tl)) crystals are widely used in radiation detection applications, from gamma-ray spectroscopy to particle dark matter searches. However, if the crystal is exposed to relative humidity of even a few…
The study of the crystal scintillating detector (based on pure CsI) is proposed with the aim of use in future Dark Matter searches. The planned energy range of the recoil nuclei detection between 2 and 40 KeV allows to register neutralino…
We estimate the event rate for excitation of atomic transition by photino-like dark matter. For excitations of several eV, this event rate can exceed naive cross-section by many orders of magnitude. Although the event rate for these atomic…
Directional detection of dark matter can provide unambiguous observation of dark matter interactions even in the presence of background. This article presents an experimental method to measure the direction tag ("head-tail") of the dark…
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on…
Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can…
Liquid noble based particle detectors often use the organic wavelength shifter 1,1,4,4- tetraphenyl-1,3-butadiene (TPB) which shifts UV scintillation light to the visible regime, facilitating its detection, but which also can scintillate on…