Related papers: Radiation hardness study using SiPMs with single-c…
The absorption length, $\lambda_{abs}$, of light with wavelengths between 0.95 and 1.30$~\mu$m in silicon irradiated with 24$~$GeV/c protons to 1$~$MeV neutron equivalent fluences between 0 and $8.6 \times 10^{15}~$cm$^{-2}$ has been…
A new generation of 3D silicon pixel detectors with a small pixel size of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$ is being developed for the HL-LHC tracker upgrades. The radiation hardness of such detectors was studied in beam tests…
To assess the viability of a shallow-depth neutrino detector, a Cosmic Muon Veto Detector (CMVD) is being constructed on top of the stack of Resistive Plate Chamber (RPC) detectors at TIFR, Mumbai. The CMVD employs extruded plastic…
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher…
The double differential cross sections for $^{nat}$In($^{28}$Si, $\pi ^{\pm}$) reactions are measured at 400, 600, and 800 MeV/nucleon. Both $\pi^+$ and $\pi^-$ are found to be emitted isotropically from a single moving source. The $\pi^- /…
High-granularity homogeneous electromagnetic calorimeters based on scintillating crystals and silicon photomultipliers (SiPMs) are a promising option for future $e^{+}e^{-}$ Higgs factories, where both excellent energy resolution and a very…
In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…
This work presents a comprehensive characterization of the FERS 5202 front-end readout unit when processing signals from Silicon Photo-multipliers (SiPMs). The readout system's performance is characterized in terms of its charge resolution,…
Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…
The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is…
Influence of the prolonged irradiation by fission products of 252Cf radionuclide on the operational parameters of silicon-lithium Si(Li) p-i-n detectors, Si surface barrier detectors and Si planar p+n detector was investigated. The obtained…
We have developed a dedicated front-end-electronics board for a high-pressure xenon gas time projection chamber for a neutrinoless double-beta decay search. The ionization signal is readout by detecting electroluminescence photons with…
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from…
The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor…
Silicon Photomultipliers (SiPMs) are photon-counting detectors with great potential to improve the sensitivity of optical receivers. Recent studies of SiPMs in communication focus on the speed rather than the power consumption of the…
A series of test experiments on three different Si-based neutron detectors, namely a 1-d 128 channel, 0.5 mm space resolution Si microstrip sensor coupled to natural Gd converter, a medium size ? 1 cm2 PIN diode coupled to nGd2O3 or…
The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a…
We report on the realization of a novel SiPM-based, cryogenic photosensor with an active area of 24 cm$^2$ that operates as a single-channel analog detector. The device is capable of single photon counting with a signal to noise ratio…
A fully kinetic 2D axisymmetric Particle-in-Cell (PIC) model is used to examine the effects of background facility pressure on the plasma transport and propulsive efficiency of magnetic nozzles. Simulations are performed for a low-power…
Photon readout of plastic scintillators is investigated with the aim of improving the precision of neutron \b{eta} decay experiments. Neutron decay is nowadays studied with high statistics, based on up to 109 registered decay events, and…