Related papers: CMS Muon Drift Tubes HL-LHC Slice Test
The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical…
The first level trigger of the CMS experiment is comprised of custom electronics that process data from the electromagnetic and hadron calorimeters and three technologies of muon detectors in order to select the most interesting events from…
The semiconductor tracker (SCT) is one of the tracking systems for charged particles in the ATLAS detector. It consists of 4088 silicon strip sensor modules. During Run 2 (2015$-$2018) the Large Hadron Collider delivered an integrated…
The Compact Muon Solenoid (CMS) detector is one of two general-purpose detectors that measure the products of high energy particle interactions in the Large Hadron Collider (LHC) at CERN. The silicon pixel detector is the innermost…
The LHCb experiment(Fig. 1), that is presently taking data at CERN (European Center for Nuclear Research) Large Hadron Collider (LHC), aims at the study of CP violation in the B meson sector. Its key elements is the Muon detector [1], which…
Dark matter scenarios are being tested at the LHC in the general-purpose experiments through promptly decaying states. In parallel, new dedicated detectors have been proposed for the LHC to probe dark matter portal theories predicting…
In next ten years, the Large Hadron Collider will be upgraded to the High Luminosity LHC (HL-LHC), resulting in ten time more integrated luminosity. To withstand the much harsher radiation and occupancy conditions of the HL-LHC, the inner…
The CMS experiment has been designed with a 2-level trigger system: the Level 1 Trigger, implemented on custom-designed electronics, and the High Level Trigger (HLT), a streamlined version of the CMS offline reconstruction software running…
In the High Luminosity Large Hadron Collider (HL-LHC) program, during the next years, the instantaneous luminosity will increase up to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$ which means a factor five higher than the nominal LHC. In that…
With the increases in the LHC instantaneous luminosity, maintaining effective triggering and avoiding dead time will become especially challenging. As the sensitivity of many physics studies, depends critically on the ability to maintain…
Since the initial data taking of the CERN LHC, the CMS experiment has undergone substantial upgrades and improvements. This paper discusses the CMS detector as it is configured for the third data-taking period of the CERN LHC, Run 3, which…
The Phase-2 ATLAS upgrade for the High Luminosity Large Hadron Collider (HL-LHC) has motivated progressive redesigns of the ATLAS Tile Calorimeter (TileCal) read-out link and control board (Daughterboard). The Daughterboard (DB)…
This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton…
The ALICE (A Large Ion Collider Experiment) Time Projection Chamber (TPC) at CERN LHC is presently equipped with Multi Wire Proportional Chambers (MWPCs). A gating grid prevents ions produced during the gas amplification from moving into…
The Level-1 Muon Barrel Trigger of the ATLAS Experiment at LHC makes use of Resistive Plate Chamber (RPC) detectors. The on-detector trigger electronics modules are able to identify muons with predefined transverse momentum values (pT) by…
If long lived charged particles exist, and produced at the LHC, they may travel with velocity significantly slower than the speed of light. This unique signature was not considered during the design of the LHC experiments, ATLAS and CMS. As…
The LHC upgrade scheduled for 2018 is expected to significantly increase the accelerator's luminosity, and as a result the radiation background rates in the ATLAS Muon Spectrometer will increase too. Some of its components will have to be…
The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5$\times10^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000-4000…
The CMS muon system is undergoing substantial upgrades to meet the challenges of the High-Luminosity LHC (HL-LHC), including the installation of the new Muon Endcap 0 (ME0) detector. Large-scale production started in 2024. ME0 is a…
The SemiConductor Tracker (SCT) together with the Pixel detector and the Transition Radiation Tracker (TRT) form the central tracking system of the ATLAS experiment at the LHC. It consists of single-sided microstrip silicon sensors, which…