Related papers: Venc Design and Velocity Estimation for Phase Cont…
In phase-contrast magnetic resonance imaging (PC-MRI), the velocity of spins at a voxel is encoded in the image phase. The strength of the velocity encoding gradient offers a trade-off between the velocity-to-noise ratio (VNR) and the…
2D cine phase contrast (CPC) MRI provides quantitative information on blood velocity and flow within the human vasculature. However, data acquisition is time-consuming, motivating the reconstruction of the velocity field from undersampled…
Purpose: To develop a fast, general-purpose framework for voxelwise noise characterization in linear and nonlinear iterative MRI reconstructions, recovering the image-domain noise variance from which SNR, $g$-factor, and related…
For many applications in signal processing and machine learning, we are tasked with minimizing a large sum of convex functions subject to a large number of convex constraints. In this paper, we devise a new random projection method (RPM) to…
Purpose: In multi-spectral imaging (MSI), several fast spin echo volumes with discrete Larmor frequency offsets are acquired in an interleaved fashion with multiple concatenations. Here, a variable resolution (VR) method to nearly halve…
The 2-D phase unwrapping problem aims at retrieving a "phase" image from its modulo $2\pi$ observations. Many applications, such as interferometry or synthetic aperture radar imaging, are concerned by this problem since they proceed by…
In phase retrieval, the goal is to recover a signal $\mathbf{x}\in\mathbb{C}^N$ from the magnitudes of linear measurements $\mathbf{Ax}\in\mathbb{C}^M$. While recent theory has established that $M\approx 4N$ intensity measurements are…
Undersampling is a common method in Magnetic Resonance Imaging (MRI) to subsample the number of data points in k-space, reducing acquisition times at the cost of decreased image quality. A popular approach is to employ undersampling…
Parallel imaging is ubiquitous in MRI, enabling diverse applications such as ultra-high-resolution functional and quantitative imaging with greater temporal resolution or reduced scan times respectively. Successful unfolding is contingent…
We address the problem of phase retrieval (PR) from quantized measurements. The goal is to reconstruct a signal from quadratic measurements encoded with a finite precision, which is indeed the case in many practical applications. We develop…
Multireference alignment (MRA) refers to the problem of recovering a signal from noisy samples subject to random circular shifts. Expectation--maximization (EM) and variational approaches use statistical modeling to achieve high accuracy at…
Speed-of-sound has been shown as a potential biomarker for breast cancer imaging, successfully differentiating malignant tumors from benign ones. Speed-of-sound images can be reconstructed from time-of-flight measurements from ultrasound…
We propose a flexible convex relaxation for the phase retrieval problem that operates in the natural domain of the signal. Therefore, we avoid the prohibitive computational cost associated with "lifting" and semidefinite programming (SDP)…
Suppose we wish to recover a signal x in C^n from m intensity measurements of the form |<x,z_i>|^2, i = 1, 2,..., m; that is, from data in which phase information is missing. We prove that if the vectors z_i are sampled independently and…
Image simulation for scanning transmission electron microscopy at atomic resolution for samples with realistic dimensions can require very large computation times using existing simulation algorithms. We present a new algorithm named PRISM…
We develop procedures, based on minimization of the composition $f(x) = h(c(x))$ of a convex function $h$ and smooth function $c$, for solving random collections of quadratic equalities, applying our methodology to phase retrieval problems.…
Phase retrieval (PR) is an inverse problem about recovering a signal from phaseless linear measurements. This problem can be effectively solved by minimizing a nonconvex amplitude-based loss function. However, this loss function is…
In imaging modalities recording diffraction data, the original image can be reconstructed assuming known phases. When phases are unknown, oversampling and a constraint on the support region in the original object can be used to solve a…
Automatic Mean Opinion Score (MOS) prediction is crucial to evaluate the perceptual quality of the synthetic speech. While recent approaches using pre-trained self-supervised learning (SSL) models have shown promising results, they only…
Many state-of-the-art methods for safety assessment and motion planning for automated driving require estimation of the probability of collision (POC). To estimate the POC, a shape approximation of the colliding actors and probability…