Related papers: Sparse multi-reference alignment: sample complexit…
Multi-reference alignment (MRA) is the problem of recovering a signal from its multiple noisy copies, each acted upon by a random group element. MRA is mainly motivated by single-particle cryo-electron microscopy (cryo-EM) that has recently…
Motivated by cutting-edge applications like cryo-electron microscopy (cryo-EM), the Multi-Reference Alignment (MRA) model entails the learning of an unknown signal from repeated measurements of its images under the latent action of a group…
The growing role of data-driven approaches to scientific discovery has unveiled a large class of models that involve latent transformations with a rigid algebraic constraint. Three-dimensional molecule reconstruction in Cryo-Electron…
The Multi-Reference Alignment (MRA) problem aims at the recovery of an unknown signal from repeated observations under the latent action of a group of cyclic isometries, in the presence of additive noise of high intensity $\sigma$. It is a…
The multi-reference alignment (MRA) problem entails estimating an image from multiple noisy and rotated copies of itself. If the noise level is low, one can reconstruct the image by estimating the missing rotations, aligning the images, and…
Motivated by single-particle cryo-electron microscopy, multi-reference alignment (MRA) models the task of recovering an unknown signal from multiple noisy observations corrupted by random rotations. The standard approach,…
Multireference alignment (MRA) problem is to estimate an underlying signal from a large number of noisy circularly-shifted observations. The existing methods are always proposed under the hypothesis of a single Gaussian noise. However, the…
Multireference alignment (MRA) is the problem of estimating a signal from many noisy and cyclically shifted copies of itself. In this paper, we consider an extension called heterogeneous MRA, where $K$ signals must be estimated, and each…
We consider the problem of estimating a signal from noisy circularly-translated versions of itself, called multireference alignment (MRA). One natural approach to MRA could be to estimate the shifts of the observations first, and infer the…
The number of noisy images required for molecular reconstruction in single-particle cryo-electron microscopy (cryo-EM) is governed by the autocorrelations of the observed, randomly-oriented, noisy projection images. In this work, we…
In cryo-electron microscopy (cryo-EM), a microscope generates a top view of a sample of randomly-oriented copies of a molecule. The problem of single particle reconstruction (SPR) from cryo-EM is to use the resulting set of noisy 2D…
Multireference alignment (MRA) refers to the problem of recovering a signal from noisy samples subject to random circular shifts. Expectation--maximization (EM) and variational approaches use statistical modeling to achieve high accuracy at…
Motivated by structural biology applications, we study the projected multi-reference alignment (MRA) model, in which an unknown signal is observed through noisy samples, each generated by applying a random cyclic shift followed by a fixed…
Motivated by the task of 2-D classification in single particle reconstruction by cryo-electron microscopy (cryo-EM), we consider the problem of heterogeneous multireference alignment of images. In this problem, the goal is to estimate a…
In this paper, a sparse-based method for the estimation of the parameters of multidimensional ($R$-D) modal (harmonic or damped) complex signals in noise is presented. The problem is formulated as $R$ simultaneous sparse approximations of…
The multi-reference alignment (MRA) problem involves reconstructing a signal from multiple noisy observations, each transformed by a random group element. In this paper, we focus on the group \(\mathrm{SO}(2)\) of in-plane rotations and…
We present the framework of slowly varying regression under sparsity, allowing sparse regression models to exhibit slow and sparse variations. The problem of parameter estimation is formulated as a mixed-integer optimization problem. We…
We study the multi-reference alignment (MRA) problem of recovering a signal from noisy observations acted on by unknown random circular shifts. While the information-theoretic limits of MRA are well characterized in many settings, the…
In this paper, we discuss application of iterative Stochastic Optimization routines to the problem of sparse signal recovery from noisy observation. Using Stochastic Mirror Descent algorithm as a building block, we develop a multistage…
From molecular imaging to wireless communications, the ability to align and reconstruct signals from multiple misaligned observations is crucial for system performance. We study the problem of multi-reference alignment (MRA), which arises…