English
Related papers

Related papers: A Tunnel Diode Oscillator for High Sensitivity Bro…

200 papers

We describe a multifunctional sample probe for transport measurements, equipped with a two-axis goniometer providing computer controlled 360${^\circ}$ out of plane and manual 360${^\circ}$ in-plane rotation. The multifunctional sample probe…

Materials Science · Physics 2018-05-04 Mustafa Öztürk , Numan Akdoğan

Levitated oscillators with millimeter or sub-millimeter size are particularly attractive due to their potential role in studying various fundamental problems and practical applications. One of the crucial issues towards these goals is to…

Quantum Physics · Physics 2021-07-21 Fang Xiong , Peiran Yin , Tong Wu , Han Xie , Rui Li , Yingchun Leng , Yanan Li , Changkui Duan , Xi Kong , Pu Huang , Jiangfeng Du

We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this…

Applied Physics · Physics 2022-05-04 M. Rosner , D. Beck , P. Fierlinger , H. Filter , C. Klau , F. Kuchler , P. Rößner , M. Sturm , D. Wurm , Z. Sun

Silicon double paddle oscillators are well suited for the detection of weak forces because of their high Q factor (about 10^5 at room temperature). We describe an experiment aimed at the detection of gravitational forces between masses at…

High Energy Physics - Phenomenology · Physics 2016-11-09 L. Haiberger , M. Weingran , H. Wenz , S. Schiller

This thesis describes the development of an ultra-low noise sapphire resonator oscillator that is tunable over X-band. While undertaking this task the author has explained some interesting and very useful phenomena in regards to the design…

General Relativity and Quantum Cosmology · Physics 2023-11-29 Michael Edmund Tobar

A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…

Astrophysics · Physics 2009-11-11 Hua Feng , Philip Kaaret , Hans Andersson

Thermal diode is a growing technology and important for active thermal flow control. Since the theoretical designing of thermal diode in 2004, various kinds of solid-state thermal diodes have been theoretically and experimentally…

Superconductivity · Physics 2025-10-02 Poonam Rani , Masayuki Mashiko , Keisuke Hirata , Ken-ichi Uchida , Yoshikazu Mizuguchi

A method is presented to measure the absolute value of the London penetration depth, $\lambda$, from the frequency shift of a resonator. The technique involves coating a high-$T_c$ superconductor (HTSC) with film of low - Tc material of…

Superconductivity · Physics 2009-10-31 R. Prozorov , R. W. Giannetta , A. Carrington , P. Fournier , R. L. Greene , D. G. Hinks , A. R. Banks

We have developed novel instrumentation for making Lagrangian measurements of temperature in diverse fluid flows. A small neutrally buoyant capsule is equipped with on-board electronics which measure temperature and transmit the data via a…

Fluid Dynamics · Physics 2011-12-06 Woodrow L. Shew , Yoann Gasteuil , Mathieu Gibert , Pascal Metz , Jean-Francois Pinton

We present direct imaging measurements of charge transport across a 1 cm x 1 cm x 4 mm-thick crystal of high purity silicon ($\sim$15 k$\Omega$-cm) at temperatures of 5 K and 500 mK. We use these data to measure the lateral diffusion of…

We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milliKelvin temperatures. The setup relies on the combination of an interferometric ampli- fication…

Mesoscale and Nanoscale Physics · Physics 2011-03-07 François D. Parmentier , Adrien Mahé , Anne Denis , Jean-Marc Berroir , D. Christian Glattli , Bernard Plaçais , Gwendal Fève

Based on test-beam measurements, we study the response of a liquid-scintillator detector equipped with wavelength-shifting optical modules, that are proposed e.g. for the IceCube experiment and the SHiP experiment, and adiabatic light…

Instrumentation and Detectors · Physics 2019-05-22 M. Ehlert , A. Hollnagel , I. Korol , A. Korzenev , H. Lacker , P. Mermod , J. Schliwinski , L. Shihora , P. Venkova , M. Wurm

When diamond anvil cell (DAC) sample chambers are outfitted with both thermal insulation and electrodes, two cutting-edge experimental methods are enabled: Joule heating with spectroradiometric temperature measurement, and electrical…

We present a set of experiments to optimize the performance of the noninvasive thermometer based on proximity superconductivity. Current through a standard tunnel junction between an aluminum superconductor and a copper electrode is…

Mesoscale and Nanoscale Physics · Physics 2020-05-06 Bayan Karimi , Danilo Nikolic , Tuomas Tuukkanen , Joonas T. Peltonen , Wolfgang Belzig , Jukka P. Pekola

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our…

Instrumentation and Detectors · Physics 2020-02-07 Dillon Wong , Sangjun Jeon , Kevin P. Nuckolls , Myungchul Oh , Simon C. J. Kingsley , Ali Yazdani

Spin polarized atomic ensembles can be used for the precise measurement of magnetic field. Conventional atomic magnetometers have demonstrated high sensitivities, albeit at low detection bandwidth, fundamentally limited by the Larmor…

We describe instrumentation for conducting high sensitivity millimeter-wave cavity perturbation measurements over a broad frequency range (40-200 GHz) and in the presence of strong magnetic fields (up to 33 tesla). A Millimeter-wave Vector…

Materials Science · Physics 2009-10-31 M. Mola , S. Hill , P. Goy , M. Gross

We achieved for the first time a direct measurement of the thermal fluctuation of a pendulum in an off-resonant region using a laser interferometric gravitational wave detector. These measurements have been well identified for over one…

The complex ac impedance of a bolometer or microcalorimeter detector is easily measured and can be used to determine thermal time constants, thermal resistances, heat capacities, and sensitivities. Accurately extracting this information…

Instrumentation and Detectors · Physics 2009-04-13 John E. Vaillancourt

We demonstrate millikelvin thermometry of laser cooled trapped ions with high-resolution imaging. This equilibrium approach is independent of the cooling dynamics and has lower systematic error than Doppler thermometry, with \pm5 mK…

Quantum Physics · Physics 2011-06-10 B. G. Norton , E. W. Streed , M. J. Petrasiunas , A. Jechow , D. Kielpinski