Related papers: High-Accuracy Absolute Magnetometry with Applicati…
The Fermi National Accelerator Laboratory (FNAL) Muon $g-2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics…
Fermilab is upgrading its Booster synchrotron to increase ramp rate and intensity. This is part of the Proton Improvement Plan (PIP-II) that will allow the Main Injector to achieve proton beam power of 1.2 MW within the next few years. This…
The new g-2 experiment at Fermilab aims to measure the muon anomalous magnetic moment by a fourfold improvement in precision compared to the BNL experiment. Achieving this goal requires the delivery of highly polarized 3.094 GeV/c muons…
The ATLAS muon spectrometer is designed to measure muon momenta with a resolution of 4% @ 100 GeV/c rising to 10% @ 1 TeV/c track momentum. The spectrometer consists of precision tracking and trigger chambers embedded in a 2T magnetic field…
The muon anomalous magnetic moment is one of the most precisely measured quantities in particle physics. In a recent experiment at Brookhaven it has been measured with a remarkable 14-fold improvement of the previous CERN experiment…
Noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement are considered. Such a magnetometer measures spin precession of $N$ atomic spins by detecting…
We describe an experimental study of spin-projection noise in a high sensitivity alkali-metal magnetometer. We demonstrate a four-fold improvement in the measurement bandwidth of the magnetometer using continuous quantum non-demolition…
The muon (g-2) experiment at BNL has completed four data runs for the positive muon, beginning in 1997 and has just finished its first run for the negative muon. Recently the analysis of a 1.3 ppm result based on the 1999 run was completed…
We provide evidence, based on direct simulation of the quantum Fisher information, that 1/N scaling of the sensitivity with the number of atoms N in an atomic magnetometer can be surpassed by double-passing a far-detuned laser through the…
A new measurement of the positive muon's anomalous magnetic moment has been made at the Brookhaven Alternating Gradient Synchrotron using the direct injection of polarized muons into the superferric storage ring. The angular frequency…
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be…
We measure the sensitivity of a broadband atomic magnetometer using quantum non-demolition spin measurements. A cold, dipole-trapped sample of rubidium atoms provides a long-lived spin system in a non-magnetic environment, and is probed…
Nuclear magnetic resonance (NMR) technique benefits from high magnetic field not only due to the field-enhanced measurement sensitivity and resolution, but also because it is a powerful tool to investigate field-induced physics in modern…
We report on an all-optical magnetometric technique based on nonlinear magneto-optical rotation with amplitude-modulated light. The method enables sensitive magnetic-field measurements in a broad dynamic range. We demonstrate the…
We show that muonium spectroscopy in the coming years can reach a precision high enough to determine the anomalous magnetic moment of the muon below one part per million (ppm). Such an independent determination of muon g-2, which is not…
We present a method of optical magnetometry with parts-per-billion resolution that is able to detect biomagnetic signals generated from the human brain and heart in Earth's ambient environment. Our magnetically silent sensors measure the…
The precise measurement of the muon anomalous magnetic moment $a_\mathrm{\mu}$ has stimulated much theoretical and experimental efforts over more than six decades. The last experiment at Brookhaven National Laboratory, Upton, NY, USA…
By combining the constraints of charge symmetry with new chiral extrapolation techniques and recent low mass lattice QCD simulations of the individual quark contributions to the magnetic moments of the nucleon octet, we obtain a precise…
We demonstrated a scalar atomic magnetometer using a micro-fabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on D1 transition of Cs atoms and detected by an…
We demonstrate an all-optical $^{133}$Cs scalar magnetometer, operating in nonzero magnetic field,in which the magnetic resonance is driven by an effective oscillating magnetic field provided by the AC Stark shift of an intensity-modulated…