English
Related papers

Related papers: A new layout about the graphite layers in RPC

200 papers

A large (240 cm $\times$ 120 cm $\times$ 0.2 cm) oil-free High Pressure Laminate (HPL), commonly referred as "bakelite", Resistive Plate Chamber (RPC) has been developed at VECC-Kolkata using locally available P-302 OLTC grade HPL. The…

Instrumentation and Detectors · Physics 2016-05-25 Rajesh Ganai , Arindam Roy , Kshitij Agarwal , Zubayer Ahammed , Subikash Choudhury , Subhasis Chattopadhyay

Resistive Plate Chambers (RPCs), used for the Muon Spectrometer of the ALICE experiment at CERN LHC, are currently operated in maxi-avalanche mode with a low threshold value and without amplification in the front-end electronics. RPC…

Instrumentation and Detectors · Physics 2020-01-29 Antonio Bianchi

Transforming the resistive plate chambers from charged-particle into gamma-quanta detectors opens the way towards their application as a basic element of a hybrid imaging system, which combines positron emission tomography (PET) with…

Instrumentation and Detectors · Physics 2015-06-12 Georgi Georgiev , Nevena Ilieva , Venelin Kozhuharov , Iglika Lessigiarska , Leandar Litov , Borislav Pavlov , Peicho Petkov

Resistive Plate Chambers detectors are extensively used in several domains of Physics. In High Energy Physics, they are typically operated in avalanche mode with a high-performance gas mixture based on Tetrafluoroethane (C2H2F4), a…

Instrumentation and Detectors · Physics 2025-10-08 D. Ahmadi , M. Tytgat

A comparative study has been performed on Resistive Plate Chambers (RPC) made of two different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon,…

Instrumentation and Detectors · Physics 2010-11-30 S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , S. Saha , M. K. Sharan , Y. P. Viyogi

Dedicated detector simulations are very important for the success of high energy physics experiments. They not only bring benefits to the optimization of the detectors, but can also improve the precision of the physics results. To design a…

Instrumentation and Detectors · Physics 2018-09-26 Fuyue Wang , Dong Han , Yi Wang , Yancheng Yu , Qiunan Zhang , Baohong Guo , Yuanjing Li

The reduction of the average charge per count in the gas along with the capability to discriminate very small signals from noise can allow an efficient and long-term Resistive Plate Chamber detector operation in high radiation background…

Instrumentation and Detectors · Physics 2020-12-30 Luca Pizzimento

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…

Instrumentation and Detectors · Physics 2023-07-19 Kensuke Yamamoto , Sei Ban , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi

There are several working groups that are currently working on high rate RPC's using different materials such as Si-based Ceramics, Low-resistive Glass, low-resistive bakelite etc. A new type of single gap RPC has been fabricated using very…

Instrumentation and Detectors · Physics 2019-07-24 S. Chakraborty , S. Chatterjee , S. Roy , A. Roy , S. Biswas , S. Das , S. K. Ghosh , S. K. Prasad , S. Raha

Muography is finding applications in various domains such as volcanology, archaeology, civil engineering, industry, mining, and nuclear waste surveys. To simplify transportation and installation in remote locations after laboratory testing,…

A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4\pi$. The high density of hits on a given particle track facilitates the task of pattern…

The detailed simulation of the Multi-gap Resistive Plate Chambers (MRPCs) provides the performance characteristics of MRPCs with different numbers of gas gaps and gap thicknesses. This helps in optimizing the structure of MRPCs under…

Instrumentation and Detectors · Physics 2024-12-31 J. Liu , Z. Chen , Y. Wang , B. Guo , D. Han , Y. Li

We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-{\eta} RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap…

The ATLAS Muon Spectrometer is undergoing a major upgrade for the High-Luminosity LHC (HL-LHC), including the addition of three new thin-gap Resistive Plate Chamber (RPC) layers in the inner barrel region. These RPCs have 1 mm gas gaps…

Instrumentation and Detectors · Physics 2025-01-10 F. Fallavollita , O. Kortner , H. Kroha , P. Maly , G. Proto , D. Soyk , E. Voevodina , J. Zimmermann

Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for high-voltage performance of such an experiment, we have developed…

Instrumentation and Detectors · Physics 2026-02-04 Shumit A. Mitra , Alexander Deisting , Jan Lommler , Uwe Oberlack , Fabian Piermaier , Quirin Weitzel , Daniel Wenz

The India-based Neutrino Observatory (INO) collaboration is planning to build a massive 50kton magnetised Iron Calorimeter (ICAL) detector, to study atmospheric neutrinos and to make precision measurements of the parameters related to…

Instrumentation and Detectors · Physics 2019-08-13 Satyanarayana Bheesette

The innermost station of the present ATLAS forward muon detector needs to be upgraded for the super-LHC. We present a proposal to replace it with a sandwiched detector composed of several layers of small-radius Monitored Drift Tube chambers…

Instrumentation and Detectors · Physics 2012-10-26 Junjie Zhu

The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. Since July 2004, about 270 RPC units has been certified at…

The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber (RMSGC) using additional field shaping strips located inside the detector substrate are described.

Instrumentation and Detectors · Physics 2014-04-01 R. Oliveira , S. Franchino , V. Peskov

Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to…

‹ Prev 1 3 4 5 6 7 10 Next ›