English
Related papers

Related papers: First magnet operation on the cryogenic test stand…

200 papers

We demonstrate successful operation of a continuous flow liquid helium magnetic cryostat (Oxford Instruments, Microstat MO) in closed cycle operation using a modular cryocooling system (ColdEdge Technologies, Stinger). For the system…

Instrumentation and Detectors · Physics 2022-01-04 K. Barr , T. Cookson , K. G. Lagoudakis

We report on the design and implementation of a rotating sample magnetometer (RSM) operating in the variable temperature insert of a cryostat equipped with a high-field magnet. The limited space and the cryogenic temperatures impose the…

Superconductivity · Physics 2015-05-28 M. Eisterer , F. Hengstberger , C. S. Voutsinas , N. Hörhager , S. Sorta , J. Hecher , H. W. Weber

We report results of the experimental test of the High Temperature Superconductor based fast cycling prototype accelerator magnet capable to operate up to about 300 Tesla per second field ramping rate with some 0.5 T field in the magnet…

Accelerator Physics · Physics 2022-05-04 Henryk Piekarz , Steven Hays , Bradley Claypool , Matthew Kufer , Vladimir Shiltsev

A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment…

Fermi National Accelerator Laboratory is constructing a superconducting 1.3 GHz cryomodule test facility located at the New Muon Lab building. The facility will be used for testing and validating cryomodule designs as well as support…

Accelerator Physics · Physics 2012-06-29 A. Martinez , A. L. Klebaner , J. C. Theilacker , B. D. DeGraff , J. Leibfritz

The cryomodule I for ADS Injection-I had been designed, fabricated and online tested. The CM1 contains seven superconducting magnets, seven superconducting spoke cavities and seven beam position monitors. The superconducting magnet, which…

Accelerator Physics · Physics 2016-01-28 Xiangchen Yang , Da Cheng , Quanling Peng , Yuan Chen , Fengyu Xu , Anbin Chen

CERN is now setting up String 2, a full-size prototype of a regular cell of the LHC arc. It is composed of two quadrupole, six dipole magnets, and a separate cryogenic distribution line (QRL) for the supply and recovery of the cryogen. An…

Instrumentation and Detectors · Physics 2007-05-23 A. Suraci , T. Bager , Ch. Balle , E. Blanco , J. Casas , P. Gomes , S. Pelletier , L. Serio , N. Vauthier

We have conducted precise magnetization measurements down to 0.5 K with a miniature 3He cryostat and a closed-cycle 3He gas handling system for a commercial superconducting quantum interference device magnetometer [Magnetic Property…

A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3…

Fast feedback from cryogenic electrical characterization measurements is key for the development of scalable quantum computing technology. At room temperature, high-throughput device testing is accomplished with a probe-based solution,…

We present a one-heater-two-thermometer set-up for measuring thermal conductivity and electric resistivity of a bulk sample at low temperatures down to 0.1 K and in magnetic fields up to 27 Tesla. The design overcomes the difficulties…

Superconductivity · Physics 2009-11-10 P. J. E. M. van der Linden , K. Behnia

A tunable magnetic field at low temperatures is essential for numerous applications, including spintronics, magnetic resonance imaging, and condensed matter physics. While commercial superconducting vector magnets are available, they are…

Instrumentation and Detectors · Physics 2025-07-25 Gaia Da Prato , Yong Yu , Ronald Bode , Simon Gröblacher

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL…

Strongly Correlated Electrons · Physics 2025-09-30 Young-Hoon Kim , Fehmi Sami Yasin , Na Yeon Kim , Max Birch , Xiuzhen Yu , Akiko Kikkawa , Yasujiro Taguchi , Jiaqiang Yan , Miaofang Chi

We have developed a versatile near-field microscopy platform that can operate at high magnetic fields and below liquid-helium temperatures. We use this platform to demonstrate an extreme terahertz (THz) nanoscope operation and to obtain the…

Mesoscale and Nanoscale Physics · Physics 2023-08-17 Richard H. J. Kim , Joong-Mok Park , Samuel J. Haeuser , Liang Luo , Jigang Wang

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…

Instrumentation and Methods for Astrophysics · Physics 2014-07-21 Shugo Oguri , Jihoon Choi , Masanori Kawai , Osamu Tajima

We describe a helium source cell for use in cryogenic experiments that is hermetically sealed $in$ $situ$ on the cold plate of a cryostat. The source cell is filled with helium gas at room temperature and subsequently sealed using a cold…

Instrumentation and Detectors · Physics 2023-11-06 K. E. Castoria , H. Byeon , J. Theis , N. R. Beysengulov , E. O. Glen , G. Koolstra , M. Sammon , S. A. Lyon , J. Pollanen , D. G. Rees

Temperature below 100 microKelvin is achieved in a customized cryogen-free dilution refrigerator with a copper-nuclear demagnetization stage. The lowest temperature of conduction electrons of the demagnetization stage is below 100…

Instrumentation and Detectors · Physics 2021-03-12 Jiaojie Yan , Jianing Yao , Vladimir Shvarts , Rui-Rui Du , Xi Lin

We tested the prototype DQW cavity in GERSEMI vertical test stand in FREIA. The performance met the specification, and our experimental procedure and infrastructure are qualified for testing crab cavities in the HL-LHC project. This was the…

Accelerator Physics · Physics 2020-11-11 A. Miyazaki , K. Fransson , K. Gajewski , L. Hermansson , R. Ruber

This paper presents the development of a high field pulsed magnet system combined with an optical fiber-coupled low temperature cryostat for magneto-photoluminescence measurements. A novel aspect of our system is the use of electrolyte…

Instrumentation and Detectors · Physics 2026-03-17 Deepesh Kalauni , Kingshuk Mukhuti , Tao Peng , Bhavtosh Bansal

We report experimental demonstration of the feasibility of reaching temperatures below 1 mK using cryogen-free technology. Our prototype system comprises an adiabatic nuclear demagnetisation stage, based on hyperfine-enhanced nuclear…

Instrumentation and Detectors · Physics 2015-06-16 Graham Batey , Andrew Casey , Michael Cuthbert , Anthony Matthews , John Saunders , Aya Shibahara
‹ Prev 1 2 3 10 Next ›