This paper presents a new phasor measurement unit (PMU)-based wide-area damping control (WADC) method to suppress the critical inter-area modes of large-scale power systems. Modal participation factors, estimated by a practically model-free…

Systems and Control · Electrical Eng. & Systems 2020-06-11 Ilias Zenelis , Xiaozhe Wang , Innocent Kamwa

This paper proposes a novel wide-area control strategy for modulating the active power injections to damp the critical frequency oscillations in power systems, this includes the inter-area oscillations and the transient frequency swing. The…

Systems and Control · Electrical Eng. & Systems 2020-03-26 Ruichao Xie , Innocent Kamwa , C. Y. Chung

One of the major issues in an interconnected power system is the low damping of inter-area oscillations which significantly reduces the power transfer capability. Advances in Wide-Area Measurement System (WAMS) makes it possible to use the…

Systems and Control · Computer Science 2018-04-19 Abhilash Patel , Sandip Ghosh , Komla A. Folly

Interconnected power grid exhibits oscillatory response after a disturbance in the system. One such type of oscillations, the inter-area oscillations has the oscillation frequency in the range of 0.1 to 1 Hz. The damping of inter-area…

Systems and Control · Electrical Eng. & Systems 2019-09-17 Abilash Thakallapelli , Sukumar Kamalasadan

As power systems become more and more interconnected, the inter-area oscillations has become a serious factor limiting large power transfer among different areas. Underdamped (Undamped) inter-area oscillations may cause system breakup and…

Systems and Control · Computer Science 2017-01-10 Jianming Lian , Shaobu Wang , Ruisheng Diao , Zhenyu Huang

Wide-area synchrophasor ambient measurements provide a valuable data source for real-time oscillation mode monitoring and analysis. This paper introduces a novel method for identifying inter-area oscillation modes using wide-area ambient…

Signal Processing · Electrical Eng. & Systems 2021-03-03 Shutang You

Inter-area oscillations in power system limit of power transfer capability though tie-lines. For stable operation, wide-area power system stabilizers are deployed to provide sufficient damping. However, as the feedback is through a…

Systems and Control · Electrical Eng. & Systems 2020-07-27 Abhilash Patel

Fundamental sensor feedback limitations for improving rotor angle stability using local frequency or phase angle measurement are derived. Using a two-machine power system model, it is shown that improved damping of inter-area oscillations…

Systems and Control · Electrical Eng. & Systems 2021-08-13 Joakim Björk , Danilo Obradović , Lennart Harnefors , Karl Henrik Johansson

Phasor Measurement Units (PMUs) convert high-speed waveform data into low-speed phasor data, which are fundamental to wide-area monitoring and control in power systems, with oscillation detection and localization among their most prominent…

Signal Processing · Electrical Eng. & Systems 2026-01-23 Bowen Ou , Bin Wang , Slava Maslennikov , Hanchao Liu , Jim Follum

Dynamic state and parameter estimation methods for dynamic security assessment in power systems are becoming increasingly important for system operators. Usually, the data used for this type of applications stems from phasor measurement…

Systems and Control · Electrical Eng. & Systems 2022-09-01 Nicolai Lorenz-Meyer , René Suchantke , Johannes Schiffer

Real-time tracking of inertia is important because it reflects the power system's ability to withstand contingencies and maintain frequency security. This paper proposes a practical approach to estimate inertia using ambient phasor…

Systems and Control · Electrical Eng. & Systems 2025-08-12 Anushka Sharma , Anamitra Pal , Rajasekhar Anguluri , Tamojit Chakraborty

Timely recognition of voltage instability is crucial to allow for effective control and protection interventions. Phasor measurements units (PMUs) can be utilized to provide high sampling rate time-synchronized voltage and current phasors…

Systems and Control · Computer Science 2013-08-05 R. Leelaruji , L. Vanfretti , J. O. Gjerde , S. Lovlund

In this paper, a novel model-free wide-area damping control (WADC) method is proposed, which can achieve full decoupling of modes and damp multiple critical inter-area oscillations simultaneously using grid-connected voltage source…

Systems and Control · Electrical Eng. & Systems 2021-02-11 Jinpeng Guo , Ilias Zenelis , Xiaozhe Wang , Boon-Teck Ooi

Integration of intermittent renewable energy sources in modern power systems is increasing very fast. Replacement of synchronous generators with zero-to-low variable renewables substantially decreases the system inertia. In a large system,…

Signal Processing · Electrical Eng. & Systems 2020-06-23 Mingjian Tuo , Xingpeng Li

Installation of phasor measurement units (PMUs) in a number of substations in the power grid can help assess a set of its values and parameters, in particular those related to the dynamics when disturbances occur in the system. Inertia…

Systems and Control · Electrical Eng. & Systems 2021-04-19 Mohammadali Hayerikhiyavi , Aleksandar Dimitrovski

In this paper, an alternating direction method of multipliers based novel distributed wide-area control architecture is proposed for damping the interarea oscillations. In this approach, first, an interconnected power system is divided into…

Systems and Control · Electrical Eng. & Systems 2019-07-16 Abilash Thakallapelli , Sukumar Kamalasadan

Big data analytic applications using phasor measurements help improve the situation awareness of grid operators to better operate and control the system. Phasor measurement unit (PMU) data from actual grids is viewed as highly confidential…

Systems and Control · Electrical Eng. & Systems 2019-09-10 Ti Xu , Hanyue Li , Adam B. Birchfield , Thomas J. Overbye

Phasor measurement units (PMUs) provide a high-resolution view of the power system at the locations where they are placed. As such, it is desirable to place them in bulk in low voltage distribution circuits. However, the power consumption…

Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…

Systems and Control · Computer Science 2016-07-12 Jian Du , Shaodan Ma , Yik-Chung Wu , H. Vincent Poor

Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…

Systems and Control · Electrical Eng. & Systems 2023-04-18 Saptarshi Ghosh , Murali Sankar Venkatraman , Shehab Ahmed , Charalambos Konstantinou