Related papers: Hefei light source storage ring bunch by bunch 3D …
This contribution presents a novel bunch current measurement system based on an ultra-fast photodetector and a high-speed digitizer at Hefei Light Source II (HLS II). In order to achieve bunch-by-bunch resolution, the sampling rate of the…
A logarithm processing algorithm to measure beam transverse size and position is proposed and preliminary experimental results in Hefei Light Source II (HLS II) are given. The algorithm is based on only 4 successive channels of 16 anode…
As the brightness of synchrotron radiation (SR) light sources improves, the operation stability of light sources is weakened. To explore various beam instability related issues in light sources, one transverse beam diagnostics system for…
HLS (Hefei Light Source) is a second generation synchrotron radiation source. After injected into the storage ring at energy of 200MeV, the electrons will be ramped to 800MeV. During ramping, the magnetic fields of the bend, quadruple and…
The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in…
The upgrade project of Hefei Light Source storage ring is under way. In this paper, the wake fields of new designed vacuum chambers have been simulated by CST code, and then broadband impedances were obtained by FFT. Together with resistive…
Shanghai Synchrotron Radiation Facility (SSRF) is a 3.5 GeV storage ring with a bunch rate of 499.654 MHz, harmonic number of 720, and circumference of 432 meters. SSRF injection works at 3.5 GeV, where the multi-bunch instabilities limit…
A scheme with two superconducting RF cavities (sc-cavities) is designed to upgrade electron storage rings with odd buckets into multi-length bunches. In this paper, Hefei Light Source II (HLS II) is given as an example for odd buckets. In…
A system was developed for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations based on the signal from a single beam-position monitor (BPM) located in a region of the ring with large amplitude functions. The…
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…
One of the optimization goals of a particle accelerator is to reach the highest possible beam peak current. For that to happen the electron bunch propagating through the accelerator should be kept relatively short along the direction of its…
The upgrade project of Hefei Light Source storage ring is under way. In this paper, the broadband impedances of resistive wall and coated ceramic vacuum chamber were calculated using the analytic formula, the wake fields and impedances of…
The UED (ultrafast electron diffraction) beamline of the KAERI's (the Korea Atomic Energy Research Institute's) WCI (World Class Institute) Center has been successfully commissioned. We have measured the beam emittance by using the…
A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Tevatron is described. It is based on the signal from a single beam-position monitor located in a region of the ring with large amplitude…
Bunch-by-bunch longitudinal diagnostics is a key issue of modern accelerators. To face up this challenging demand, tests of mid-IR compact uncooled photoconductive HgCdTe detectors have been recently performed at DAFNE. Different devices…
We report the design and performance of a time-resolved electron diffraction apparatus capable of producing intense bunches with simultaneously single digit micron probe size, long coherence length, and $200$ fs rms time resolution. We…
We report the design, operation and performance of a high-resolution, low-latency, bunch-by-bunch feedback system for nano-beam stabilisation. The system employs novel, ultra-low quality-factor cavity beam position monitors (BPMs), a…
Hefei Light Source (HLS) is being upgraded to HLS II. Its emittance will be much lower than before, therefore the Touschek scattering will increase significantly and become the dominant factor of beam loss. So it is necessary to build a new…
Shanghai Synchrotron Radiation Facility (SSRF), is one of the third-generation high-beam current (3.5 GeV) synchrotron light sources. In the storage ring of SSRF, multi-bunch instabilities would increase beam emittance and energy spread,…
The High Energy Photon Source (HEPS), is the first fourth-generation storage ring light source being built in the suburb of Beijing, China. The storage ring was designed with the emittance lower than 60 pm.rad with a circumference of 1.36…