English
Related papers

Related papers: 3D cosmic-ray muon tomography using portable muogr…

200 papers

Muon radiography often referred to as muography, is an imaging technique that uses freely available cosmic-ray muons to study the interior structure of natural or man-made large-scale objects. The amount of multidisciplinary applications of…

We present an underground cosmic ray muon tomographic experiment imaging 3D density of overburden, part of a joint study with differential gravity. Muon data were acquired at four locations within a tunnel beneath Los Alamos, New Mexico,…

The possibility to build a SiPM-readout muon detector (SiRO), using plastic scintillators with optical fibers as sensitive volume and readout by SiPM photo-diodes, is investigated. SiRO shall be used for tracking cosmic muons based on…

Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography…

Instrumentation and Detectors · Physics 2016-11-17 M. Hohlmann , K. Gnanvo , L. Grasso , J. B. Locke , A. Quintero , D. Mitra

Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…

Instrumentation and Detectors · Physics 2026-04-06 Chenghan Lv , Kun Hu , Huiling Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Weiwei Xu

Muon radiography is an innovative and non-destructive technique for internal density structure imaging, based on measuring the attenuation of cosmic-ray muons after they penetrate the target. Due to the strong penetration ability of muons,…

Instrumentation and Detectors · Physics 2023-07-19 Xin Mao , Zhiwei Li , Shuning Dong , Jingtai Li , Jianming Zhang , Jie Pang , Yaping Cheng , Bin Liao , Xiaoping Ouyang , Ran Han

Imaging techniques that use atmospheric muons, collectively named under the neologism "muography", have seen a tremendous growth in recent times, mainly due to their diverse range of applications. The most well-known ones include but are…

Instrumentation and Detectors · Physics 2020-12-09 S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , M. Moussawi , M. Tytgat , S. Wuyckens

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines…

A high spatial resolution tracking system was setup with the Micro-mesh gaseous structure (Micromegas) detectors in order to study the muon tomographic imaging technique for nuclear threat detection. 6 layers of 90 mm $\times$ 90 mm…

Instrumentation and Detectors · Physics 2022-09-12 Liu Cheng-Ming , Wen Qun-Gang , Zhang Zhi-Yong , Huang Guang-Shun

Muon tomography is a relatively new method of radiography that utilizes muons from cosmic rays and their multiple Coulomb scattering property to distinguish materials. Researchers around the world have been developing various detection…

Instrumentation and Detectors · Physics 2019-12-20 Weihe Zeng , Xingyu Pan , Zhi Zeng , Hao Ma , Ming Zeng , Jianping Cheng

Cosmic-ray muon tomography is a promising technique for border security applications, leveraging highly penetrating cosmic-ray muons and their interactions with various materials to generate 3D images of large and dense objects, such as…

Applied Physics · Physics 2025-09-25 Anzori Sh. Georgadze

The muon radiography technique is part of the straight-ray scanning imaging methods and it is usually employed to produce two-dimensional images of the integrated density in the radial direction from the detector position. However, in the…

Instrumentation and Detectors · Physics 2021-02-03 Guglielmo Baccani

Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing shipping containers is a promising candidate for identifying threatening high-Z materials. Since position-sensitive detectors…

Instrumentation and Detectors · Physics 2009-06-25 Marcus Hohlmann , Patrick Ford , Kondo Gnanvo , Jennifer Helsby , David Pena , Richard Hoch , Debasis Mitra

In this paper, we present development of a portable cosmic muon tracker tailored for both on-site measurements of cosmic muon flux as well as for outreach activities. The tracker comprises of two 70 mm x 70 mm plastic scintillators,…

Instrumentation and Detectors · Physics 2026-03-02 Yuvaraj Elangovan , Shashwat Kakkad , B. Satyanarayana

Point of colsest Approche algorithm (PoCA) based on the formalism of muon radiogra- phy using Multiple Coulomb scattering (MCS) as information source is previously used to obtain the reconstruction image of high Z material. The low accuracy…

Instrumentation and Detectors · Physics 2018-06-05 Xiao-Dong Wang , Kai-Xuan Ye , Yi Wang , Yu-Lei Li , Xie Wei , Ling-Yi Luo , Guo-Xiang Chen

Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…

Among numerous applications of muon tomography, deployment in civil structures has caught attraction of many recently. In this work, the appropriateness of muon scattering tomography to detect defects in concrete structures has been studied…

High Energy Physics - Experiment · Physics 2021-03-23 Sridhar Tripathy , Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay

The civil engineering industry faces a critical need for innovative non-destructive evaluation methods, particularly for ageing critical infrastructure, such as bridges, where current techniques fall short. Muography, a non-invasive imaging…

Image and Video Processing · Electrical Eng. & Systems 2025-04-03 William O'Donnell , David Mahon , Guangliang Yang , Simon Gardner

The muon tomography technique, based on multiple Coulomb scattering of cosmic ray muons, has been proposed as a tool to detect the presence of high density objects inside closed volumes. In this paper a new and innovative method is…