English
Related papers

Related papers: The EXO-200 detector, part II: Auxiliary Systems

200 papers

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation…

nEXO is a proposed experiment that will search for neutrinoless double-beta decay (0$\nu\beta\beta$) in 5-tonnes of liquid xenon (LXe), isotopically enriched in $^{136}$Xe. A technique called Ba-tagging is being developed as a potential…

The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this…

Nuclear Experiment · Physics 2023-10-04 NEXT Collaboration , P. Novella , M. Sorel , A. Usón , C. Adams , H. Almazán , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , S. Bounasser , N. Byrnes , S. Cárcel , J. V. Carrión , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , T. Contreras , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , M. Elorza , J. Escada , R. Esteve , A. Fahs , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , E. D. C. Freitas , Z. Freixa , J. Generowicz , A. Goldschmidt , J. J. Gómez-Cadenas , R. González , J. Grocott , R. Guenette , J. Haefner , K. Hafidi , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , J. Ho , P. Ho , Y. Ifergan , B. J. P. Jones , L. Labarga , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , D. Lopez Gutierrez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , G. Martínez-Lema , M. Martínez-Vara , Z. E. Meziani , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , J. Muñoz Vidal , K. E. Navarro , A. Nuñez , D. R. Nygren , E. Oblak , M. Odriozola-Gimeno , J. Palacio , B. Palmeiro , A. Para , I. Parmaksiz , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , J. Rodríguez , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , A. Simón , S. R. Soleti , C. Stanford , J. M. R. Teixeira , J. F. Toledo , J. Torrent , J. F. C. A. Veloso , T. T. Vuong , J. Waiton , J. T. White

This article reviews the progress made over the last 20 years in the development and applications of liquid xenon detectors in particle physics, astrophysics and medical imaging experiments. We begin with a summary of the fundamental…

Instrumentation and Detectors · Physics 2010-12-01 E. Aprile , T. Doke

An ultimate liquid xenon experiment would be limited in its dark matter science reach by irreducible neutrino backgrounds, which are an exciting signal in their own right. To achieve such sensitivity, other backgrounds that currently plague…

High Energy Physics - Experiment · Physics 2024-02-27 Abigail Kopec

We investigate the detection prospects for two-neutrino and neutrinoless second order weak decays of $^{124}$Xe -- double electron capture ($0/2\nu\text{ECEC}$), electron capture with positron emission ($0/2\nu\text{EC}\beta^+$) and…

Nuclear Experiment · Physics 2020-12-30 Christian Wittweg , Brian Lenardo , Alexander Fieguth , Christian Weinheimer

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K…

Instrumentation and Detectors · Physics 2015-06-11 Elena Aprile , Ran Budnik , Bin Choi , Hugo Contreras , Karl Giboni , Luke Goetzke , Rafael Lang , Kyungeun Lim , Antonio melgarejo , Petr Shagin

We propose a new detector concept, GraXe (to be pronounced as grace), to search for neutrinoless double beta decay in Xe-136. GraXe combines a popular detection medium in rare-event searches, liquid xenon, with a new, background-free…

Instrumentation and Detectors · Physics 2012-02-28 J. J. Gomez-Cadenas , F. Guinea , M. M. Fogler , M. I. Katsnelson , J. Martin-Albo , F. Monrabal , J. Muñoz-Vidal

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search…

Instrumentation and Detectors · Physics 2026-01-13 NEXT Collaboration , M. Pérez Maneiro , M. Martínez-Vara , S. Torelli , G. Martínez-Lema , P. Novella , J. A. Hernando Morata , J. J. Gómez-Cadenas , C. Adams , H. Almazán , V. Álvarez , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , Y. Ayyad , C. D. R. Azevedo , K. Bailey , F. Ballester , J. E. Barcelon , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodoline , N. Byrnes , A. Castillo , E. Church , L. Cid , M. Cid , X. Cid , C. A. N. Conde , C. Cortes-Parra , F. P. Cossío , R. Coupe , E. Dey , P. Dietz , C. Echeverria , M. Elorza , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , F. W. Foss , Z. Freixa , J. García-Barrena , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , A. F. B. Isabel , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. Marauri , A. P. Marques , J. Martín-Albo , A. Martínez , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , D. R. Nygren , E. Oblak , J. Palacio , B. Palmeiro , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Querol , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , E. Ruiz-Chóliz , P. Saharia , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , A. L. M. Silva , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , P. R. G. Valle , M. Vanga , P. Vázquez Cabaleiro , J. F. C. A. Veloso , J. D. Villamil , J. Waiton , A. Yubero-Navarro

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target…

We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas…

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons,…

In recent years cooling technology for Liquid Xenon (LXe) detectors has advanced driven by the development of Dark Matter (DM) detectors with target mass in the 100 - 1,000 kg range. The next generation of DM detectors based on LXe will be…

Instrumentation and Detectors · Physics 2019-09-24 K. L. Giboni , P. Juyal , E. Aprile , Y. Zhang , J. Naganoma

In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which…

Instrumentation and Detectors · Physics 2017-10-11 F. J. Iguaz , F. Aznar , J. F. Castel , S. Cebrian , T. Dafni , J. Galan , J. G. Garza , I. G. Irastorza , G. Luzon , H. Mirallas , E. Ruiz-Choliz

A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector…

NEXT (Neutrino Experiment with a Xenon TPC) is an experimental program whose goals are to discover neutrinoless double beta decay using $^{136}$Xe in high pressure xenon TPCs with electroluminescent readout. In this paper, results from the…

High Energy Physics - Experiment · Physics 2019-06-06 J. J. Gomez-Cadenas

We report the search for neutrinoless double-beta decay of $^{136}$Xe from the PandaX-4T experiment with a 3.7-tonne natural xenon target. The data reconstruction and the background modeling are optimized in the MeV energy region. A blind…

A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay…

Future liquid-xenon (LXe) based observatories for rare processes, such as XLZD, require testing of large components and sub-assemblies in cryogenic liquid or gaseous xenon environments. Here we present results from the stable operation of a…