Related papers: Phase-Aberration Correction in Shear-wave Elastogr…
Ultrasound shear wave elastography (SWE) is a noninvasive way to measure stiffness of soft tissue for medical diagnosis. In SWE imaging, an acoustic radiation force induces tissue displacement, which creates shear waves (SWs) that travel…
For beamforming ultrasound (US) signals, typically a spatially constant speed-of-sound (SoS) is assumed to calculate delays. As SoS in tissue may vary relatively largely, this approximation may cause wavefront aberrations, thus degrading…
Recent ultrasound imaging modalities based on ultrasound computed tomography indicate a huge potential to detect pathologies is tissue due to altered biomechanical properties. Especially the imaging of speed-of-sound (SoS) distribution in…
Shear-wave elastography (SWE) permits local estimation of tissue elasticity, an important imaging marker in biomedicine. This recently-developed, advanced technique assesses the speed of a laterally-travelling shear wave after an acoustic…
In share wave elastography (SWE), the aim is to measure the velocity of shear waves, however unwanted compression waves and bulk tissue motion pose challenges in evaluating tissue stiffness. Conventional approaches often struggle to…
The utilization of a reverberant shear wave field in shear wave elastography has emerged as a promising technique for achieving robust shear wave speed (SWS) estimation. However, accurately measuring SWS within such a complex wave field…
Shear-wave elastography (SWE) measures shear-wave speed (SWS), which is related to the underlying shear modulus of soft tissue. SWE methods generally assume that soft tissue viscoelasticity is independent of mechanical loading, however,…
In ultrasound beamforming, focusing time delays are typically computed with a spatially constant speed-of-sound (SoS) assumption. A mismatch between beamforming and true medium SoS then leads to aberration artifacts. Other imaging…
Speed-of-sound (SoS) is a novel imaging biomarker for assessing biomechanical characteristics of soft tissues. SoS imaging in pulse-echo mode using conventional ultrasound systems with hand-held transducers has the potential to enable new…
Conventional ultrasound (US) imaging employs the delay and sum (DAS) receive beamforming with dynamic receive focus for image reconstruction due to its simplicity and robustness. However, the DAS beamforming follows a geometrical method of…
Most ultrasound (US) imaging techniques use spatially-constant speed-of-sound (SoS) values for beamforming. Having a discrepancy between the actual and used SoS value leads to aberration artifacts, e.g., reducing the image resolution, which…
Elastic properties of arteries have long been recognized as playing a major role in the cardiovascular system. However, non-invasive in vivo assessment of local arterial stiffness remains challenging and imprecise as current techniques rely…
Objective: Ultrasound elastography is gaining traction as an accessible and useful diagnostic tool for such things as cancer detection and differentiation and thyroid disease diagnostics. Unfortunately, state of the art shear wave imaging…
In this paper, we propose Plane Wave Elastography (PWE), a novel ultrasound shear wave elastography (SWE) approach. Currently, commercial methods for SWE rely on directional filtering based on the prior knowledge of the wave propagation…
Ultrasound Shear Wave Elastography (USWE) with conventional B-mode imaging demonstrates better performance in lesion segmentation and classification problems. In this article, we propose SHEAR-net, an end-to-end deep neural network, to…
Computed ultrasound tomography in echo mode generates maps of tissue speed of sound (SoS) from the shift of echoes when detected under varying steering angles. It solves a linearized inverse problem that requires regularization to…
Quantitative speed-of-sound (SoS) and attenuation of tissues are closely related to pathology; however, conventional B-mode images are limited to qualitative visualization. Existing ultrasound full-waveform inversion (FWI) methods for…
Shear wave elastography involves applying a non-invasive acoustic radiation force to the tissue and imaging the induced deformation to infer its mechanical properties. This work investigates the use of convolutional neural networks to…
Most ultrasound imaging techniques necessitate the fundamental step of converting temporal signals received from transducer elements into a spatial echogenecity map. This beamforming (BF) step requires the knowledge of speed-of-sound (SoS)…
We use supersonic shear wave imaging (SSI) technique to measure not only the linear but also the nonlinear elastic properties of brain matter. Here, we tested six porcine brains ex vivo and measured the velocities of the plane shear waves…