Related papers: A Precise Method to Determine the Energy Scale and…
A neutron detector based on EJ301 liquid scintillator has been employed at EAST to measure the neutron energy spectrum for D-D fusion plasma. The detector was carefully characterized in different quasi-monoenergetic neutron fields generated…
We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons escaping from the scintillator with an array of…
The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted…
Energy resolution and the detection efficiency for gamma quanta are fundamental properties in the construction of detectors for ionizing radiation. In this study, a SiPM-based photodetector coupled to a monolithic inorganic CeBr_{3} crystal…
We measure the mass difference, \Delta m_0, between the D*(2010)+ and the D0 and the natural line width, \Gamma, of the transition D*(2010)+ -> D0 pi+. The data were recorded with the BABAR detector at center-of-mass energies at and near…
Future neutrino experiments at low energies such as JUNO or THEIA will use large volume homogeneous liquid scintillator detectors. The optical attenuation length of the liquid is of uttermost importance for the successful realization of…
A physically-motivated function was developed to accurately determine the total absorption peak in an electromagnetic calorimeter and to overcome biases present in many commonly used methods. The function is the convolution of a detector…
To overcome the problem of inefficient computing time and unreliable results in MCNP5 calculation, a two-step method is adopted to calculate the energy deposition of prompt gamma-rays in detectors for depleted uranium spherical shells under…
In this study, we propose a novel fully active total absorption calorimeter with enhanced read out capabilities through fine splitting. The proposed calorimeter employs a sandwich structure composed of scintillator glasses and lead glasses,…
Determination of the neutrino mass hierarchy in a reactor neutrino experiment at medium baseline is discussed. Observation of the interference effects between the \Delta m^2_{31} and \Delta m^2_{32} oscillations enables a relative…
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…
Study of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with different thickness, each coupled with 12 x…
Nowadays it is possible to determine the type of gas with sufficient accuracy when its concentration is less than {10}^{-6} (in units of ppm) fractions using spectroscopic methods (optical, radio engineering, acoustic). Along with this, the…
The understanding of the instrumental response of the GLAST Burst Monitor BGO detectors at energies above the energy range which is accessible by common laboratory radiation sources (< 4.43 MeV), is important, especially for the later…
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…
Sensitivity limits are usually determined using the Cram\'er-Rao bound. Recently this approach has been used to obtain the ultimate resolution limit for the estimation of the separation between two incoherent point sources. However, methods…
The binding energies of 29Si, 33S, and 36Cl have been measured with a relative uncertainty $< 0.59 \times 10^{-6}$ using a flat-crystal spectrometer. The unique features of these measurements are 1) nearly perfect crystals whose lattice…
Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT 4…
The design of the new space-based gamma-ray telescope GAMMA-400 is presented. GAMMA-400 is optimized for the energy 100 GeV with the best parameters: the angular resolution ~0.01 deg, the energy resolution ~1%, and the proton rejection…
The linear response of CsI(Tl) crystals to $\gamma$-rays plays a crucial role in their calibration, as any deviation from linearity can introduce systematic errors not negligible in the measurement of $\gamma$ energy spectra, particularly…