English
Related papers

Related papers: TED-net: Convolution-free T2T Vision Transformer-b…

200 papers

Low-dose computed tomography (LDCT) denoising is an important problem in CT research. Compared to the normal dose CT (NDCT), LDCT images are subjected to severe noise and artifacts. Recently in many studies, vision transformers have shown…

Image and Video Processing · Electrical Eng. & Systems 2023-03-29 Dayang Wang , Fenglei Fan , Zhan Wu , Rui Liu , Fei Wang , Hengyong Yu

To reduce the potential radiation risk, low-dose CT has attracted much attention. However, simply lowering the radiation dose will lead to significant deterioration of the image quality. In this paper, we propose a noise reduction method…

Medical Physics · Physics 2016-10-04 Hu Chen , Yi Zhang , Weihua Zhang , Peixi Liao , Ke Li , Jiliu Zhou , Ge Wang

Low-dose CT denoising is a challenging task that has been studied by many researchers. Some studies have used deep neural networks to improve the quality of low-dose CT images and achieved fruitful results. In this paper, we propose a deep…

Image and Video Processing · Electrical Eng. & Systems 2019-02-28 Maryam Gholizadeh-Ansari , Javad Alirezaie , Paul Babyn

Low-dose computed tomography (CT) has attracted a major attention in the medical imaging field, since CT-associated x-ray radiation carries health risks for patients. The reduction of CT radiation dose, however, compromises the…

Computer Vision and Pattern Recognition · Computer Science 2019-07-16 Hongming Shan , Yi Zhang , Qingsong Yang , Uwe Kruger , Mannudeep K. Kalra , Ling Sun , Wenxiang Cong , Ge Wang

Low-dose Computed Tomography (LDCT) reconstruction is an important task in medical image analysis. Recent years have seen many deep learning based methods, proved to be effective in this area. However, these methods mostly follow a…

Image and Video Processing · Electrical Eng. & Systems 2023-02-08 Runyi Li

Computed tomography (CT) has played a vital role in medical diagnosis, assessment, and therapy planning, etc. In clinical practice, concerns about the increase of X-ray radiation exposure attract more and more attention. To lower the X-ray…

Image and Video Processing · Electrical Eng. & Systems 2022-01-19 Zhicheng Zhang , Xiaokun Liang , Wei Zhao , Lei Xing

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

With the development of deep learning, medical image processing has been widely used to assist clinical research. This paper focuses on the denoising problem of low-dose computed tomography using deep learning. Although low-dose computed…

Image and Video Processing · Electrical Eng. & Systems 2026-05-19 Zhilin Guan , Wei Zhang

The extensive use of medical CT has raised a public concern over the radiation dose to the patient. Reducing the radiation dose leads to increased CT image noise and artifacts, which can adversely affect not only the radiologists judgement…

Image and Video Processing · Electrical Eng. & Systems 2021-07-13 Jiajin Zhang , Hanqing Chao , Xuanang Xu , Chuang Niu , Ge Wang , Pingkun Yan

Given the potential X-ray radiation risk to the patient, low-dose CT has attracted a considerable interest in the medical imaging field. The current main stream low-dose CT methods include vendor-specific sinogram domain filtration and…

Medical Physics · Physics 2017-12-12 Hu Chen , Yi Zhang , Mannudeep K. Kalra , Feng Lin , Yang Chen , Peixi Liao , Jiliu Zhou , Ge Wang

Low Dose Computed Tomography (LDCT) is clinically desirable due to the reduced radiation to patients. However, the quality of LDCT images is often sub-optimal because of the inevitable strong quantum noise. Inspired by their unprecedent…

Image and Video Processing · Electrical Eng. & Systems 2021-02-02 Ti Bai , Dan Nguyen , Biling Wang , Steve Jiang

Reducing the radiation exposure for patients in Total-body CT scans has attracted extensive attention in the medical imaging community. Given the fact that low radiation dose may result in increased noise and artifacts, which greatly…

Image and Video Processing · Electrical Eng. & Systems 2023-07-19 Minghan Fu , Yanhua Duan , Zhaoping Cheng , Wenjian Qin , Ying Wang , Dong Liang , Zhanli Hu

While various deep learning methods were proposed for low-dose computed tomography (CT) denoising, they often suffer from over-smoothing, blurring, and lack of explainability. To alleviate these issues, we propose a plug-and-play…

Image and Video Processing · Electrical Eng. & Systems 2024-03-12 Zhihao Chen , Tao Chen , Chenhui Wang , Chuang Niu , Ge Wang , Hongming Shan

Low-dose computed tomography (LDCT) reduces radiation exposure but suffers from image artifacts and loss of detail due to quantum and electronic noise, potentially impacting diagnostic accuracy. Transformer combined with diffusion models…

Image and Video Processing · Electrical Eng. & Systems 2025-07-01 Qiqing Liu , Guoquan Wei , Zekun Zhou , Yiyang Wen , Liu Shi , Qiegen Liu

Low-dose computed tomography (LDCT) is critical for minimizing radiation exposure, but it often leads to increased noise and reduced image quality. Traditional denoising methods, such as iterative optimization or supervised learning, often…

Computer Vision and Pattern Recognition · Computer Science 2025-09-23 Debopom Sutradhar , Ripon Kumar Debnath , Mohaimenul Azam Khan Raiaan , Yan Zhang , Reem E. Mohamed , Sami Azam

Low-dose computed tomography (LDCT) became a clear trend in radiology with an aspiration to refrain from delivering excessive X-ray radiation to the patients. The reduction of the radiation dose decreases the risks to the patients but…

Image and Video Processing · Electrical Eng. & Systems 2021-02-05 Elvira Zainulina , Alexey Chernyavskiy , Dmitry V. Dylov

Low dose computed tomography (LDCT) is desirable for both diagnostic imaging and image guided interventions. Denoisers are openly used to improve the quality of LDCT. Deep learning (DL)-based denoisers have shown state-of-the-art…

Image and Video Processing · Electrical Eng. & Systems 2020-12-08 Ti Bai , Biling Wang , Dan Nguyen , Bao Wang , Bin Dong , Wenxiang Cong , Mannudeep K. Kalra , Steve Jiang

In the past few decades, to reduce the risk of X-ray in computed tomography (CT), low-dose CT image denoising has attracted extensive attention from researchers, which has become an important research issue in the field of medical images.…

Image and Video Processing · Electrical Eng. & Systems 2021-03-09 Tengfei Liang , Yi Jin , Yidong Li , Tao Wang , Songhe Feng , Congyan Lang

Noise in low-dose computed tomography (LDCT) can obscure important diagnostic details. While deep learning offers powerful denoising, supervised methods require impractical paired data, and self-supervised alternatives often use opaque,…

Image and Video Processing · Electrical Eng. & Systems 2026-02-19 Yipeng Sun , Linda-Sophie Schneider , Siyuan Mei , Jinhua Wang , Ge Hu , Mingxuan Gu , Chengze Ye , Fabian Wagner , Lan Song , Siming Bayer , Andreas Maier

In order to reduce the potential radiation risk, low-dose CT has attracted more and more attention. However, simply lowering the radiation dose will significantly degrade the imaging quality. In this paper, we propose a noise reduction…

Medical Physics · Physics 2016-09-28 Hu Chen , Yi Zhang , Weihua Zhang , Peixi Liao , Ke Li , Jiliu Zhou , Ge Wang
‹ Prev 1 2 3 10 Next ›