English
Related papers

Related papers: An Upgrade Path for the Fermilab Accelerator Compl…

200 papers

Over the next 6 years the CDF and D0 collaborations have the goal of collecting 15 fb-1 of data in collider Run II. This will require a number of ambitious upgrades to the Fermilab accelerator complex, some of which have been completed,…

High Energy Physics - Experiment · Physics 2007-05-23 Mike Church

The Fermilab Booster uses multi-turn beam injection with all its cavities phased such that beam sees a net zero RF voltage even when each station is at the same maxi-mum voltage. During beam capture the RF voltage is increased slowly by…

Preinjector VEPP-5 electron linac consists of two linear accelerators on energy 300 MeV and 510 MeV and includes 14 accelerating structures [1]. First accelerating structures both linacs have increased average rate of acceleration 25-30…

Accelerator Physics · Physics 2007-05-23 5 Team

This document describes the concept of a primary electron beam facility at CERN, to be used for dark gauge force and light dark matter searches. The electron beam is produced in three stages: A Linac accelerates electrons from a…

Accelerator Physics · Physics 2018-06-01 T. Åkesson , Y. Dutheil , L. Evans , A. Grudiev , Y. Papaphilippou , S. Stapnes

The Fermilab booster has an intensity upgrade plan called the Proton Improvement plan (PIP). The flux throughput goal is 2E17 protons/hour which is almost double the current operation at 1.1E17 protons/hour. The beam loss in the machine is…

Accelerator Physics · Physics 2013-01-31 K. Seiya , C. Drennan , W. A. Pellico , K. Triplett , A. Waller

Project-X is a proposed project to be built at Fermi National Accelerator Laboratory with several potential missions. A primary part of the Project-X accelerator chain is a Superconducting linac, and In October 2009 a workshop was held to…

Accelerator Physics · Physics 2012-02-02 J. Galambos , R. Garoby , S. Geer

For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available…

Accelerator Physics · Physics 2016-12-20 A. L. Edelen , S. G. Biedron , S. V. Milton , D. Bowring , B. E. Chase , J. P. Edelen , D. Nicklaus , J. Steimel

The Fermilab proton source is capable of providing 8 GeV protons for both the future long-baseline neutrino program (NuMI), and for a new program of low energy muon experiments. In particular, if the 8 GeV protons are rebunched and then…

Accelerator Physics · Physics 2007-05-23 C. Ankenbrandt , D. Bogert , F. DeJongh , S. Geer , D. McGinnis , D. Neuffer , M. Popovic , E. Prebys

A CW-compatible, pulsed H- superconducting linac is envisaged as a possible path for upgrading Fermilab's injection complex. To validate the concept of the front- end of such a machine, a test accelerator (a.k.a. PXIE) is under…

Accelerator Physics · Physics 2015-02-06 A. Shemyakin , M. Alvarez , R. Andrews , C. Baffes , A. Chen , B. Hanna , L. Prost , G. Saewert , V. Scarpine , J. Steimel , D. Sun , D. Li , R. D'Arcy

A superconducting RF accelerator test facility is currently under construction at Fermilab. The accelerator will consist of an electron gun, 40 MeV injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, and…

Accelerator Physics · Physics 2012-09-19 M. Church , J. Leibfritz , S. Nagaitsev

The Muon Campus at Fermilab provides world class accelerator infrastructure supporting the next generation intensity frontier experiments. The anti-proton source from the Tevatron era was converted to the present day Muon Campus at the end…

Accelerator Physics · Physics 2022-08-08 S. Ganguly

The Paul Scherrer Institut in Switzerland operates the high intensity proton accelerator facility HIPA. A 590 MeV kinetic energy proton beam of presently up to 2.4 mA is sent to target stations producing pions, muons and neutrons for…

High Energy Physics - Phenomenology · Physics 2016-07-26 Klaus Kirch

This paper describes the concept of a primary electron beam facility at CERN, to be used for dark gauge force and light dark matter searches. The electron beam is produced in three stages: A Linac accelerates electrons from a photo-cathode…

Accelerator Physics · Physics 2019-05-21 T. Åkesson , R. Corsini , Y. Dutheil , L. Evans , B. Goddard , A. Grudiev , A. Latina , Y. Papaphilippou , S. Stapnes

Recent performance of Fermilab's Tevatron has exceeded this year's design goals and further accelerator upgrades are underway. The high-luminosity period which follows these improvements is known as Run IIb. The D0 experiment is in the…

High Energy Physics - Experiment · Physics 2019-08-14 Breese Quinn

Project X is a high intensity proton facility that will support a world-leading Intensity Frontier research program over the next several decades at Fermilab. When compared to other facilities in the planning stages elsewhere in the world…

Accelerator Physics · Physics 2013-06-24 Stephen Holmes , Sergei Nagaitsev , Robert Tschirhart

For the future neutrino oscillation experiment DUNE, liquid argon time projections chambers with a fiducial mass of 10 kton each are foreseen. The dual phase concept is one of the two implementations considered, wherein electrons produced…

Instrumentation and Detectors · Physics 2019-05-22 T. Lux

PIP-II beam transfer line (BTL) to transport the beam from PIP-II Linac to the Booster ring at Fermilab. One crucial aspect of the BTL design involved the implementation of collimators. These collimators play a vital role in removing large…

Accelerator Physics · Physics 2023-12-15 M. Xiao , F. Ostiguy , D. Johnson

The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam…

Accelerator Physics · Physics 2012-08-22 A. Lumpkin , R. Flora , A. S. Johnson , J. Ruan , J. Santucci , V. Scarpine , Y. -E. Sun , R. Thurman-Keup , M. Church , M. Wendt

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer…

Accelerator Physics · Physics 2025-11-26 M. A. Balcewicz , C. Y. Tan

The upgrade of the normal conducting (NC) Radioactive Ion Beam EXperiment (REX)-ISOLDE heavy ion accelerator at CERN, under the High Intensity and Energy (HIE)-ISOLDE framework, proposes the use of superconducting (SC) quarter-wave…

Accelerator Physics · Physics 2009-06-20 M. A. Fraser , M. Pasini , R. M. Jones , M. Lindroos