English
Related papers

Related papers: Parameterizing the Angular Distribution of Emissio…

200 papers

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines…

In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30 ps TOF resolution,…

Time-of-flight positron emission tomography (TOF-PET) detectors exhibiting multiple coincidence time resolution (CTR) components, such as those induced by the mixing of Cherenkov and scintillation photons, have attracted increasing…

Medical Physics · Physics 2026-05-29 Kibo Ote , Fumio Hashimoto , Yuya Onishi , Ryosuke Ota , Maxime Toussaint , Francis Loignon-Houle

The use of Time Of Flight (TOF) in Positron Emission Tomography (PET) is expected to reduce noise on images, thanks to the additional information. In clinical routine, a common reconstruction approach is the use of maximum likelihood…

Medical Physics · Physics 2019-10-16 Luca Presotto , Elisabetta De Bernardi , Valentino Bettinardi

Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly…

Positron Emission Tomography (PET) is a functional imaging modality that enables the visualization of biochemical and physiological processes across various tissues. Recently, deep learning (DL)-based methods have demonstrated significant…

Image and Video Processing · Electrical Eng. & Systems 2026-01-16 Yiran Sun , Osama Mawlawi

Positron Emission Tomography (PET) image reconstruction is inherently challenged by Poisson noise and physical degradation factors, which are further exacerbated in limited-angle acquisitions. While deep learning methods demonstrate…

Computer Vision and Pattern Recognition · Computer Science 2026-05-11 Rüveyda Yilmaz , Yuli Wu , Johannes Stegmaier , Volkmar Schulz

In positron emission tomography (PET), it is indispensable to perform attenuation correction in order to obtain the quantitatively accurate activity map (tracer distribution) in the body. Generally, this is carried out based on the…

Medical Physics · Physics 2025-10-16 Liyang Hu , Chong Chen

The purpose of this study was to show how advanced concepts of compact, lossless and "Time Of Flight" (TOF) capable electronics similar to those foreseen for the LHC and ILC experiments could be fairly and easily transferred to the medical…

Instrumentation and Detectors · Physics 2009-08-03 P. -E. Vert , J. Lecoq , G. Montarou , N. Pauna , B. Joly , M. Boutemeur , H. Mathez , R. Gaglione , P. Le Dû

To obtain high-quality positron emission tomography (PET) scans while reducing radiation exposure to the human body, various approaches have been proposed to reconstruct standard-dose PET (SPET) images from low-dose PET (LPET) images. One…

Image and Video Processing · Electrical Eng. & Systems 2023-08-22 Zeyu Han , Yuhan Wang , Luping Zhou , Peng Wang , Binyu Yan , Jiliu Zhou , Yan Wang , Dinggang Shen

Deep learning-based reconstruction of positron emission tomography(PET) data has gained increasing attention in recent years. While these methods achieve fast reconstruction,concerns remain regarding quantitative accuracy and the presence…

Positron emission tomography (PET) is an important modality for diagnosing diseases such as cancer and Alzheimer's disease, capable of revealing the uptake of radiolabeled molecules that target specific pathological markers of the diseases.…

Medical Physics · Physics 2025-01-17 Hsin-Hsiung Huang , Zheyuan Zhu , Slun Booppasiri , Zhuo Chen , Shuo Pang , Chien-Min Kao

Iterative methods for tomographic image reconstruction have great potential for enabling high quality imaging from low-dose projection data. The computational burden of iterative reconstruction algorithms, however, has been an impediment in…

Image and Video Processing · Electrical Eng. & Systems 2019-07-25 Kai Zhang , Alireza Entezari

SPECT provides a mechanism to perform absorbed-dose quantification tasks for $\alpha$-particle radiopharmaceutical therapies ($\alpha$-RPTs). However, quantitative SPECT for $\alpha$-RPT is challenging due to the low number of detected…

We developed a positron emission tomography (PET) system for multiple-isotope imaging. Our PET system, named multiple-isotope PET (MI-PET), can distinguish between different tracer nuclides using coincidence measurement of prompt…

Limited-angle electron tomography aims to reconstruct 3D shapes from 2D projections of Transmission Electron Microscopy (TEM) within a restricted range and number of tilting angles, but it suffers from the missing-wedge problem that causes…

Computer Vision and Pattern Recognition · Computer Science 2026-05-05 Zhantao Deng , Mériem Er-Rafik , Anna Sushko , Cécile Hébert , Pascal Fua

The application of a matrix-based reconstruction protocol for obtaining Molecular Frame (MF) photoelectron angular distributions (MFPADs) from laboratory frame (LF) measurements (LFPADs) is explored. Similarly to other recent works on the…

Chemical Physics · Physics 2021-09-01 Margaret Gregory , Paul Hockett , Albert Stolow , Varun Makhija

Dual-energy computed tomography (DECT) has shown great potential and promising applications in advanced imaging fields for its capabilities of material decomposition. However, image reconstructions and decompositions under sparse views…

Medical Physics · Physics 2016-08-01 Lei Li , Ailong Cai , Linyuan Wang , Bin Yan , Hanming Zhang , Zhizhong Zheng , Wenkun Zhang , Wanli Lu , Guoen Hu

Positron Emission Tomography (PET) is an important molecular imaging tool widely used in medicine. Traditional PET systems rely on complete detector rings for full angular coverage and reliable data collection. However, incomplete-ring PET…

Computer Vision and Pattern Recognition · Computer Science 2026-05-26 Yeqi Fang , Rong Zhou

Electrical impedance tomography (EIT) is an imaging modality in which the conductivity distribution inside a target is reconstructed based on voltage measurements from the surface of the target. Reconstructing the conductivity distribution…

Mathematical Physics · Physics 2012-07-05 Antti Lipponen , Aku Seppänen , Jari Kaipio
‹ Prev 1 2 3 10 Next ›