English
Related papers

Related papers: New design approach of Front-End Electronics for h…

200 papers

Future experiments of nuclear and particle physics are moving towards the high luminosity regime, in order to access suppressed processes like rare B decays or exotic charmonium resonances. In this scenario, high rate capability is a key…

Instrumentation and Detectors · Physics 2015-02-18 M. Cardinali , O. Corell , M. I. Ferretti Bondy , M. Hoek , W. Lauth , C. Rosner , C. Sfienti , M. Thiel

Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders require the use of time information in tracking, due to the expected levels of…

Instrumentation and Detectors · Physics 2023-01-27 Gian Matteo Cossu , Adriano Lai

Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders requires the use of time information in tracking, due to the increasing levels…

Instrumentation and Detectors · Physics 2020-08-25 Adriano Lai , Gian Matteo Cossu

The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…

This paper describes the design and testing results of an 8 channels preamplifier-discriminator circuit based on a resistive feedback Transimpedance Amplifier architecture and a Leading-Edge Discriminator stage for fast high-accuracy time…

Instrumentation and Detectors · Physics 2021-10-26 Abderrahmane Ghimouz , Fatah Ellah Rarbi , Olivier Rossetto

A new approach was developed for the design of front-end circuits for semiconductor radiation detectors. The readout scheme consists of a first stage made of only a few components located close to the detector, and of a remote second stage…

Instrumentation and Detectors · Physics 2014-09-02 L. Cassina , C. Cattadori , A. Giachero , C. Gotti , M. Maino , G. Pessina

Precision instrumentation systems, such as optical receivers and other current-output measurement systems, often contain a transimpedance amplifier (TIA). The commonly used resistive feedback TIA (RF-TIA) has a drawback in its practical…

Signal Processing · Electrical Eng. & Systems 2020-05-07 Jung-hoon Noh

We characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering…

A closed-form approximate expression is presented for the short time-frame development of silicon diode sensor signals in the context of high frame-rate detection of incident X-ray fluxes, in the limit that the X-ray absorption profile…

Instrumentation and Detectors · Physics 2020-04-22 Bruce A. Schumm

We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by…

Instrumentation and Detectors · Physics 2009-10-31 D. Yvon , V. Sushkov , R. Bernard , J. L. Bret , B. Cahan , O. Cloue , O. Maillard , B. Mazeau , J. P. Passerieux , B. Paul , C. Veyssiere

We developed a high-speed and low-noise time-domain current measurement scheme using a homemade GaAs high-electron-mobility-transistor-based cryogenic transimpedance amplifier (TIA). The scheme is versatile for broad cryogenic current…

Mesoscale and Nanoscale Physics · Physics 2024-09-10 Heorhii Bohuslavskyi , Masayuki Hashisaka , Takase Shimizu , Takafumi Akiho , Koji Muraki , Norio Kumada

The next generation of collider experiments require tracking detectors with extreme performance capabilities in terms of spatial resolution (tens of $\mu \text{m}$), radiation hardness ($10^{17}~1~$MeV n$_{eq}/$cm$^2$) and timing resolution…

Instrumentation and Detectors · Physics 2023-01-05 Gian Matteo Cossu , Adriano Lai

We present the performance and application of a commercial off-the shelf Si PIN diode (Hamamatsu S14605) as a charged particle detector in a compact ion beam system (IBS) capable of generating D-D and p-B fusion charged particles. This…

With the new generation of the RPC, it is possible to work with induced signals of hundreds $\mu V$, hence the front-end electronics is an important and delicate part of the detector in order to get a detectable signal. The electronic chain…

In the readout electronics of the Water Cerenkov Detector Array (WCDA) in the Large High Altitude Air Shower Observatory (LHAASO) experiment, both high-resolution charge and time measurement are required over a dynamic range from 1…

Instrumentation and Detectors · Physics 2016-08-03 Cong Ma , Lei Zhao , Yu-Xiang Guo , Jian-Feng Liu , Shu-Bin Liu , Qi An

We have developed preamplifier configurations used to readout resistive bolometers such as those based on Neutron Transmuted Doped Germanium thermometers (so called NTD Ge thermometers)[1] or NbSi thin film thermometers [2, 3]. We introduce…

Astrophysics · Physics 2015-06-24 D. Yvon , V. Sushkov

This paper presents the design and implementation of the front-end electronics and the data acquisition (DAQ) system for readout of multi-wire drift chambers (MWDC). Apart of the conventional drift time measurement the system delivers the…

Instrumentation and Detectors · Physics 2015-12-09 K. Lojek , D. Rozpedzik , K. Bodek , M. Perkowski , N. Severijns

This paper studies the problem of fault detection and estimation (FDE) for linear time-invariant (LTI) systems with a particular focus on frequency content information of faults, possibly as multiple disjoint continuum ranges, and under…

Systems and Control · Electrical Eng. & Systems 2024-10-02 Jingwei Dong , Kaikai Pan , Sergio Pequito , Peyman Mohajerin Esfahani

The High-Acceptance DiElectron Spectrometer (HADES) at GSI Darmstadt consists of a 6-coil toroidal magnet centered on the beam axis and six identical detection sections located between the coils and covering polar angles between $18^\circ$…

Instrumentation and Detectors · Physics 2023-04-05 A. Blanco , P. Fonte , L. Lopes , J. Saraiva

A fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid…

Instrumentation and Detectors · Physics 2026-04-01 I-Chun Cho , Chien-Hsu Chen , Huan Niu , Cheng-Ya Pan , Chun-Hui Hsing , Tung-Yuan Hsiao
‹ Prev 1 2 3 10 Next ›