Related papers: The visualisation of two-dimensional dose distribu…

200 papers

With X-ray radiation protection and dose management constantly gaining interest in interventional radiology, novel procedures often undergo prospective dose studies using anthropomorphic phantoms to determine expected dose values. Due to…

The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was…

Purpose: The purpose of the work was experimental investigations of the breast dose distributions with adaptive filtration. Adaptive filtration reduces detector dynamic range and improves image quality. The adaptive filter with…

Medical Physics · Physics 2017-02-15 Polad M. Shikhaliev

Radiation dose is an important performance indicator of a dedicated breast CT (DBCT). In this paper, the method of putting thermoluminescent dosimeters (TLD) into a breast shaped PMMA phantom to study the dose distribution in breasts was…

Medical Physics · Physics 2013-05-14 Shen Shan-Wei , Wang Yan-Fang , Shu Hang , Tang Xiao , Wei Cun-Feng , Song Yu-Shou , Shi Rong-Jian , Wei Long

Ultraportable X-ray devices are ideal for TB screening in resource-limited settings. Unfortunately, guidelines on the radiation safety of these devices are lacking. The aim of the study was to determine the radiation dose by scattered and…

Medical Physics · Physics 2024-06-17 Leonie E Paulis , Roald S Schnerr , Jarred Halton , Zhi Zhen Qin , Arlene Chua

Dose distribution (depthwise and laterally) to organs outside the radiotherapy treatment field can be significant and therefore is of clinical interest from the radiation protection point of view. In the present work, measurements were…

Medical Physics · Physics 2012-03-19 Md. Farid Ahmed , S. Roy , G. U. Ahmed , F. K. Miah

Computed Tomography (CT) measures the attenuation coefficient of an object and converts the value assigned to each voxel into a CT number. In radiation therapy, CT number, which is directly proportional to the linear attenuation…

Medical Physics · Physics 2015-03-13 Dong Joo Rhee , Sung-woo Kim , Young Min Moon , Jung Ki Kim , Dong Hyeok Jeong

We describe a method aiming at increasing the dynamic range of X-ray detectors. Two X-ray exposures of an object are acquired at different dose levels and constitute the only input data. The values of the parameters which are needed to…

Medical Physics · Physics 2007-05-23 Evangelos Matsinos , Wolfgang Kaissl

Background: X-ray dark-field radiography uses small-angle scattering to visualize the structural integrity of lung alveoli. To study the influence of dose reduction on clinical dark-field radiographs, one can simulate low-dose images by…

Medical Physics · Physics 2026-01-19 Henriette Bast , Rafael C. Schick , Thomas Koehler , Franz Pfeiffer

In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we…

Pencil x-ray beam imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries due to the illumination of a line instead of an area or volume. However, the pencil beam geometry suffers…

Medical Physics · Physics 2021-02-01 Ignacio O. Romero , Changqing Li

We conducted a multi-institutional audit of dosimetric variability between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3D-printed mouse phantom. A CT scan of a live mouse was used to…

Purpose: To verify dose delivery and quality assurance of volumetric modulated arc therapy (VMAT) for head and neck cancer. Method: The Imaging and Radiation Oncology Core Houston (IROC-H) head and neck phantom with thermo- luminescent…

Dose volume histograms are a useful tool in state-of-the-art radiotherapy planning, and it is essential to be aware of their limitations. Dose distributions computed by treatment planning systems are affected by several sources of…

Medical Physics · Physics 2007-06-13 Francisco Cutanda-Henriquez , Silvia Vargas-Castrillon

Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…

Recently, X-ray imaging dose from computed tomography (CT) or cone beam CT (CBCT) scans has become a serious concern. Patient-specific imaging dose calculation has been proposed for the purpose of dose management. While Monte Carlo (MC)…

Medical Physics · Physics 2015-05-30 Xun Jia , Hao Yan , Xuejun Gu , Steve B. Jiang

The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to…

Purpose: To characterize image quality, imaging dose, and dose calculation accuracy for an upright CT scanner with a six-degree-of-freedom patient positioning system. Methods: Imaging dose (CTDIvol) was measured at 120 kVp and 200 mAs.…

The percentage depth dose distributions in inhomogeneous phantoms with lung and bone equivalent media are studied. For lung equivalent media a Balsa wood is used, and for a soft bone equivalent media a compound material with epoxy resin,…

X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and opaque instruments. In most commercial x-ray modalities, an image is formed by measuring the x-rays that pass through the object of…

Medical Physics · Physics 2023-05-23 A. Ben Yehuda , O. Sefi , Y. Klein , R. H Shukrun , H. Schwartz , E. Cohen , S. Shwartz