English
Related papers

Related papers: The gas flow pattern through a small size Resistiv…

200 papers

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Instrumentation and Detectors · Physics 2010-05-07 Burak Bilki , John Butler , Ed May , Georgios Mavromanolakis , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

Resistive Plate Chambers (RPCs) have traditionally operated with high Global Warming Potential (GWP) gas mixtures, adding to the environmental footprint of large-scale physics experiments. In response, efforts are underway to explore…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah , Thomas Adolphus , Yingchang Zhang , Oleg Brandt

Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized…

Instrumentation and Detectors · Physics 2022-01-05 L. Mao , F. Lagarde , J. Guo , X. Wang , J. Li , Q. Shen , J. Zhu , H. Yang

Gaseous detectors have long been used by particle physics experiments at beamlines or standalone experiments. Recently, their low momentum threshold has made them interesting as active targets for long baseline neutrino experiments. To…

Instrumentation and Detectors · Physics 2019-11-13 Philip Hamacher-Baumann

The mitigation of human-induced climate change is of crucial importance for the sustainability of humankind. For this aim the RPC community has exerted considerable effort over the last decade to reduce the emission of greenhouse gases from…

Instrumentation and Detectors · Physics 2020-12-30 L. Lopes P. Assis , A. Blanco , P. Fonte , M. Pimenta

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

The present paper is meant as an update of the presentation given in a previous Resistive Plate Chamber (RPC) workshop, aimed at finding an eco-friendly gas mixture for streamer operation of RPCs. Indeed the streamer working regime is still…

Instrumentation and Detectors · Physics 2019-09-04 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

A Pilot unit of a closed loop gas (CLS) mixing and distribution system for the INO project was designed and is being operated with (1.8 x 1.9) m^2 glass RPCs (Resistive Plate Chamber). The performance of an RPC depends on the quality and…

Instrumentation and Detectors · Physics 2017-02-07 S. D. Kalmani , S. Mondal , R. R. Shinde , P. V. Hunagund

The requirement of high rate capability for operation at LHC, led 20 years ago to the achievement of Resistive Plate Chambers operated in avalanche mode, thanks to the introduction of new gas mixtures and to the development of the Front-End…

Instrumentation and Detectors · Physics 2017-06-28 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

Instrumentation and Detectors · Physics 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

Time Projection Chambers (TPCs) operated at high pressure have become a topic of interest for future long baseline neutrino experiments. Pressurized gas retains the low momentum threshold for particle detection of atmospheric TPCs, but…

Instrumentation and Detectors · Physics 2021-09-01 Philip Hamacher-Baumann , Stefan Roth , Thomas Radermacher , Nick Thamm

In the last two decades Resistive Plate Chambers were employed in the Cosmic Ray Experiments COVER-PLASTEX and ARGO/YBJ. In both experiments the detectors were housed indoors, likely owing to gas distribution requirements and the need to…

Instrumentation and Detectors · Physics 2016-10-12 L. Lopes , P. Assis , A. Blanco , N. Carolino , M. A. Cerda , R. Conceição , O. Cunha , M. Ferreira , P. Fonte , R. Luz , L. Mendes , A. Pereira , M. Pimenta , R. Sarmento , B. Tomé

A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The…

Instrumentation and Detectors · Physics 2015-05-20 B. Bilki , F. Corriveau , B. Freund , C. Neubüser , Y. Onel , J. Repond , J. Schlereth , L. Xia

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

The phase-out of Hydrofluorocarbons (HFCs), due to their high Global Warming Potential (GWP), affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluorethane C2H2F4, has created operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2025-02-21 A. Blanco , Mário Carvalho , Susete Fetal , Luis Lopes , Telmo Paes , Joana Pinto , Paulo Fonte

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

Dedicated detector simulations are very important for the success of high energy physics experiments. They not only bring benefits to the optimization of the detectors, but can also improve the precision of the physics results. To design a…

Instrumentation and Detectors · Physics 2018-09-26 Fuyue Wang , Dong Han , Yi Wang , Yancheng Yu , Qiunan Zhang , Baohong Guo , Yuanjing Li
‹ Prev 1 2 3 10 Next ›