Related papers: Spinning Pupil Aberration Measurement for anisopla…
Mitigating the far sidelobes of a wide field-of-view telescope is one of the critical issues for polarization observation of the cosmic microwave background. Since even small reflections of stray light at the millimeter-wave absorbers…
For microlensing case angular distances between images or typical astrometric shifts due to microlensing are about $10^{-5}-10^{-6} \mu as$. Such an angular resolution will be reached with the space space--ground interferometer Radioastron.…
Simultaneous, diffraction-limited control of multiple optical beams is crucial for applications ranging from lithography to optogenetics, deep tissue imaging, and tweezer-based manipulation of cells, particles, or atoms. Despite the desire…
Future large space telescopes will be equipped with adaptive optics (AO) to overcome wavefront aberrations and achieve high contrast for imaging faint astronomical objects, such as earth-like exoplanets and debris disks. In contrast to AO…
We demonstrate a new approach to calibrating the spectral-spatial response of a wide-field spectrograph using a fibre etalon comb. Conventional wide-field instruments employed on front-line telescopes are mapped with a grid of…
Wavefront shaping is a technique to study and control light transport inside scattering media. Wavefront shaping is considered to be applicable to any complex material, yet in most previous studies, the only sample geometries that are…
Multi-photon microscopy is a powerful technique for deep-tissue imaging, providing high spatial resolution at increased penetration depth. Nevertheless, imaging remains largely restricted to superficial tissue layers well below 1 mm.…
The classic Hartmann test consists of an array of holes to reconstruct the wavefront from the local deviation of each focal spot, and Shack-Hartmann sensor improved that with an array of microlenses. This array of microlenses imposes…
Imaging faint objects, such as exoplanets or disks, around nearby stars is extremely challenging because host star images are dominated by the telescope diffraction pattern. Using a coronagraph is an efficient solution for removing…
Ptychography is an imaging technique which involves a sample being illuminated by a coherent, localized probe of illumination. When the probe interacts with the sample, the light is diffracted and a diffraction pattern is detected. Then the…
We address for the first time the issue of motion blur in light field images captured from plenoptic cameras. We propose a solution to the estimation of a sharp high resolution scene radiance given a blurry light field image, when the…
A Deformable Mirror (DM) is an important component of an Adaptive Optics system. It is known that an on-axis spherical/parabolic optical component, placed at an angle to the incident beam introduces defocus as well as astigmatism in the…
The basic outline of a pupil plane WaveFront Sensor is reviewed taking into account that the source to be sensed could be different from an unresolved source, i.e. it is extended, and that it could deploy also in a 3D fashion, enough to…
Images obtained with single-conjugate adaptive optics (AO) show spatial variation of the point spread function (PSF) due to both atmospheric anisoplanatism and instrumental aberrations. The poor knowledge of the PSF across the field of view…
The Ultraviolet/Optical Telescope (UVOT) is one of three instruments onboard the Swift observatory. The photometric calibration has been published, and this paper follows up with details on other aspects of the calibration including a…
In this paper, an alternative to the classical pupil apodization techniques (use of an amplitude pupil mask) is proposed. It is shown that an apodized pupil suitable for imaging of Extrasolar planets can be obtained by reflection of an…
Direction-dependent instrumental polarisation introduces wide-field polarimetric aberrations and limits the dynamic range of low-frequency interferometric images. We therefore provide a detailed two-dimensional analysis of the Giant…
The Hartmann test is a method used to measure the wavefront error in a focal optical system, wherein a mask with a pattern of small holes is placed at the system's aperture stop. By taking an image at a defocused plane, the differences…
All observations by the aperture photometer (PHT-P) and the far-infrared (FIR) camera section (PHT-C) of ISOPHOT included reference measurements against stable internal fine calibration sources (FCS) to correct for temporal drifts in…
Transit spectroscopy of habitable planets orbiting late-type stars requires high relative spectro-photometric accuracy between wavelengths during transit/eclipse observation. The spectro-photometric signal is not affected only by image…