Related papers: Determination of Position Resolution for LYSO Scin…
The study of the response of the two modules of the large-angle electromagnetic shower calorimeter (LAC) of the CLAS detector to charged and neutral particles is reported. The results agree very well with the Monte Carlo simulation. The…
CALIFA is the high efficiency and energy resolution calorimeter for the R3B experiment at FAIR, intended for detecting high energy light charged particles and gamma rays in scattering experiments, and is being commissioned during the…
The time resolution for a charged particle detection is reported for a typical scintillating fiber detector instrumented with Rockwell HISTE-IV Visible Light Photon Counters. The resolution measurements are shown to agree with a simple…
Shashlyk electromagnetic calorimeter modules with an energy resolution of about 3%/sqrt{E (GeV)} for 50-1000 MeV photons has been developed, and a prototype tested. Details of these improved modules, including mechanical construction,…
The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact…
At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…
We report on the measurements performed using a 22Na source on a detector element for an MRI-compatible TOF-PET endorectal prostate probe, with Depth-Of-Interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with…
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to…
In prospect of its application in cryogenic rare-event searches, we have investigated the low-temperature scintillation properties of CaWO4 crystals down to 3.4 K under {\alpha} and {\gamma} excitation. Concerning the scintillation decay…
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed…
A simulation study of energy resolution, position resolution, and $\pi^0$-$\gamma$ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the…
The Integrating Miniature Piggyback for Impulsive Solar Hard X-rays (IMPISH) is a solar X-ray spectrometer that features large-area scintillators, fast readout electronics, and good energy resolution in the hard X-ray band. IMPISH is a…
We examine three dense high-Z scintillating crystals for the $\mu \to e$ conversion experiment using the GEANT4 simulation toolkit. The full energy deposition, albedo, and longitudinal and lateral energy leakages for all crystal assemblies…
To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response…
We present the performance of a 33 g Li2MoO4 crystal working as a scintillating bolometer. The crystal was tested for more than 400 h in a dilution refrigerator installed in the underground laboratory of Laboratori Nazionali del Gran Sasso…
A particle traversing a crystal aligned with one of its crystallographic axes experiences a strong electromagnetic field that is constant along the direction of motion over macroscopic distances. For $e^\pm$ and $\gamma$-rays with energies…
Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET…
Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…
A Shashlyk calorimeter prototype for the KOPIO experiment has been constructed and experimentally tested. The energy resolution of about 4%/sqrt(E(GeV)) for 0.5-2.0 GeV/c positrons was obtained. Based on this results as well as on the…
We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…