English
Related papers

Related papers: Determination of Position Resolution for LYSO Scin…

200 papers

The study of the response of the two modules of the large-angle electromagnetic shower calorimeter (LAC) of the CLAS detector to charged and neutral particles is reported. The results agree very well with the Monte Carlo simulation. The…

CALIFA is the high efficiency and energy resolution calorimeter for the R3B experiment at FAIR, intended for detecting high energy light charged particles and gamma rays in scattering experiments, and is being commissioned during the…

The time resolution for a charged particle detection is reported for a typical scintillating fiber detector instrumented with Rockwell HISTE-IV Visible Light Photon Counters. The resolution measurements are shown to agree with a simple…

High Energy Physics - Experiment · Physics 2009-10-30 Alan Bross , Ana Lucia Chaves , Jesse Costa , Marvin Johnson , Lourival Moreira , Joey Thompson

Shashlyk electromagnetic calorimeter modules with an energy resolution of about 3%/sqrt{E (GeV)} for 50-1000 MeV photons has been developed, and a prototype tested. Details of these improved modules, including mechanical construction,…

The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact…

Medical Physics · Physics 2015-03-13 Joong Hyun Kim , Mikiko Ito , Soo Mee Kim , Seong Jong Hong , Jae Sung Lee

At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…

Instrumentation and Detectors · Physics 2023-03-01 Yuanjing Ji , Zebo Tang , Chen Li , Xin Li , Ming Shao

We report on the measurements performed using a 22Na source on a detector element for an MRI-compatible TOF-PET endorectal prostate probe, with Depth-Of-Interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with…

Instrumentation and Detectors · Physics 2015-06-11 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to…

Instrumentation and Detectors · Physics 2012-09-28 CALICE Collaboration , C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , T. Buanes , G. Eigen , Y. Mikami , N. K. Watson , T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , D. Benchekroun , A. Hoummada , Y. Khoulaki , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , G. Falley , K. Gadow , P. Göttlicher , C. Günter , B. Hermberg , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Feege , E. Garutti , I. Marchesini , M. Ramilli , P. Eckert , T. Harion , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , P. D. Dauncey , A. -M. Magnan , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , V. Balagura , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Rusinov , E. Tarkovsky , N. Kirikova , V. Kozlov , P. Smirnov , Y. Soloviev , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , C. Kiesling , S. Pfau , K. Seidel , F. Simon , C. Soldner , M. Szalay , M. Tesar , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , F. Dulucq , M. Faucci Giannelli , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , T. Takeshita , S. Uozumi , J. Sauer , S. Weber , C. Zeitnitz

In prospect of its application in cryogenic rare-event searches, we have investigated the low-temperature scintillation properties of CaWO4 crystals down to 3.4 K under {\alpha} and {\gamma} excitation. Concerning the scintillation decay…

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed…

Instrumentation and Detectors · Physics 2023-07-05 CUPID , CROSS collaborations , : , K. Alfonso , A. Armatol , C. Augier , F. T. Avignone , O. Azzolini , M. Balata , I. C. Bandac , A. S. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , V. Berest , M. Beretta , M. Bettelli , M. Biassoni , J. Billard , V. Boldrini , A. Branca , C. Brofferio , C. Bucci , J. M. Calvo-Mozota , J. Camilleri , A. Campani , C. Capelli , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , E. Celi , C. Chang , D. Chiesa , M. Clemenza , I. Colantoni , S. Copello , E. Craft , O. Cremonesi , R. J. Creswick , A. Cruciani , A. D'Addabbo , G. D'Imperio , S. Dabagov , I. Dafinei , F. A. Danevich , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , T. Dixon , V. Dompé , A. Drobizhev , L. Dumoulin , G. Fantini , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , L. Foggetta , J. Formaggio , A. Franceschi , C. Fu , S. Fu , B. K. Fujikawa , A. Gallas , J. Gascon , S. Ghislandi , A. Giachero , A. Gianvecchio , M. Girola , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , C. Grant , P. Gras , P. V. Guillaumon , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , A. Ianni , L. Imbert , J. Johnston , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , S. I. Konovalov , R. Kowalski , T. Langford , M. Lefevre , R. Liu , Y. Liu , P. Loaiza , L. Ma , M. Madhukuttan , F. Mancarella , C. A. Marrache-Kikuchi , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , Ph. Mas , D. Mayer , G. Mazzitelli , Y. Mei , S. Milana , S. Morganti , T. Napolitano , M. Nastasi , J. Nikkel , S. Nisi , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , E. Olivieri , M. Olmi , J. L. Ouellet , S. Pagan , C. Pagliarone , L. Pagnanini , L. Pattavina , M. Pavan , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , D. V. Poda , O. G. Polischuk , I. Ponce , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , A. Ressa , R. Rizzoli , C. Rosenfeld , P. Rosier , J. A. Scarpaci , B. Schmidt , V. Sharma , V. N. Shlegel , V. Singh , M. Sisti , P. Slocum , D. Speller , P. T. Surukuchi , L. Taffarello , C. Tomei , J. A. Torres , V. I. Tretyak , A. Tsymbaliuk , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , R. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , M. Xue , L. Yan , J. Yang , V. Yefremenko , V. I. Umatov , M. M. Zarytskyy , J. Zhang , A. Zolotarova , S. Zucchelli

A simulation study of energy resolution, position resolution, and $\pi^0$-$\gamma$ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the…

Instrumentation and Detectors · Physics 2017-08-02 Ashim Roy , Shilpi Jain , Sunanda Banerjee , Satyaki Bhattacharya , Gobinda Majumder

The Integrating Miniature Piggyback for Impulsive Solar Hard X-rays (IMPISH) is a solar X-ray spectrometer that features large-area scintillators, fast readout electronics, and good energy resolution in the hard X-ray band. IMPISH is a…

We examine three dense high-Z scintillating crystals for the $\mu \to e$ conversion experiment using the GEANT4 simulation toolkit. The full energy deposition, albedo, and longitudinal and lateral energy leakages for all crystal assemblies…

Instrumentation and Detectors · Physics 2012-12-19 Zafar Usubov

To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response…

Instrumentation and Detectors · Physics 2016-06-24 M. Angelucci , O. Atanova , S. Baccaro , A. Cemmi , M. Cordelli , R. Donghia , S. Giovannella , F. Happacher , S. Miscetti , I. Sarra , S. R. Soleti

We present the performance of a 33 g Li2MoO4 crystal working as a scintillating bolometer. The crystal was tested for more than 400 h in a dilution refrigerator installed in the underground laboratory of Laboratori Nazionali del Gran Sasso…

Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET…

Instrumentation and Detectors · Physics 2018-05-18 Andrei Yu. Semenov

Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…

Instrumentation and Detectors · Physics 2019-09-19 J. M. C. Brown , S. E. Brunner , D. R. Schaart

A Shashlyk calorimeter prototype for the KOPIO experiment has been constructed and experimentally tested. The energy resolution of about 4%/sqrt(E(GeV)) for 0.5-2.0 GeV/c positrons was obtained. Based on this results as well as on the…

Instrumentation and Detectors · Physics 2009-11-10 G. S. Atoian , V. V. Issakov , O. V. Karavichev , T. L. Karavicheva , A. A. Poblaguev , M. E. Zeller

We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…

‹ Prev 1 3 4 5 6 7 10 Next ›