Related papers: Thermal Neutron Measurements with an Unpowered, Mi…
The far site detector complex of the Daya Bay reactor experiment is proposed as a location to search for sterile neutrinos with > eV mass. Antineutrinos from a 500 kCi 144Ce-144Pr beta-decay source (DeltaQ=2.996 MeV) would be detected by…
A thermocouple of Au-Ni with only 2.5-micrometers-wide electrodes on a 30-nm-thick Si3N4 membrane was fabricated by a simple low-resolution electron beam lithography and lift off procedure. The thermocouple is shown to be sensitive to heat…
An upgrade of the long baseline neutrino experiment T2K near detector ND280 is currently being developed with the goal to reduce systematic uncertainties in the prediction of number of events at the far detector Super-Kamiokande. The…
This is an updated version of the NOvA proposal. The detector is a 30 kiloton tracking calorimeter, 15.7 m by 15.7 m by 132 m long, with alternating horizontal and vertical rectangular cells of liquid scintillator contained in PVC extrusion…
We report on measurements of thermal neutron fluxes at different locations in the STAR experimental hall during pp $\sqrt s$ = 510 GeV Run 13 at RHIC. We compared these measurements with calculations based on \textsc{PYTHIA} as minimum bias…
The purpose of the present paper is to study the neutrino properties as they may appear in the low energy neutrinos emitted in triton decay, with maximum neutrino energy of 18.6 KeV. The technical challenges to this end can be summarized as…
The response of Superheated Superconducting Granule (SSG) devices to nuclear recoils has been explored by irradiating SSG detectors with a 70Me$\!$V neutron beam. In the past we have tested Al SSG and more recently, measurements have been…
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on…
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent…
We propose applications of Radioactive Ion Beam facilities to investigate physics beyond the Standard Model. In particular, we focus on the possible measurement of coherent neutrino-nucleus scattering and on a search for sterile neutrinos,…
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at…
Operating on a surface with high noise rates and requiring susceptible, yet small-scale detectors, the Neutrinos-Angra detector is an excellent platform for technological development and expertise in new detection methods. This report…
Quantitative thermal imaging has the potential of reliable temperature measurement across an entire field-of-view. This non-invasive technique has applications in aerospace, manufacturing and process control. However, robust temperature…
The MINERvA experiment is designed to perform precision studies of neutrino-nucleus scattering using $\nu_\mu$ and ${\bar\nu}_\mu$ neutrinos incident at 1-20 GeV in the NuMI beam at Fermilab. This article presents a detailed description of…
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with…
A magnetized large-volume liquid scintillator might be used as a tracking detector with charge identification to measure high-energy neutrinos. I consider neutrino oscillations for a beam from a low-energy neutrino factory to such a…
In this paper, the design and the performance of a prototype detector based on MicroMegas technology with two detection planes in a common gas volume is discussed. The detector is suited for the forward region of LHC detectors, addressing…
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…
We demonstrate a blackbody radiation thermometer based on optically excited rubidium atoms in a vapor cell. The temperature measurement is fast, with statistical uncertainty as low as 0.1% in one second. We resolve temperature with a…
The use of Thin-foil Proton Recoil (TPR) spectrometers for application in neutron spectroscopy is of high relevance for future fusion devices such as ITER, where neutron spectroscopy will play a crucial role in fuel content monitoring.…