A prototype quasi-parasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard $^3$He proportional counters is conceptualized, designed, simulated, calibrated, and commissioned.…

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…

A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten…

Instrumentation and Detectors · Physics 2009-10-06 R. McNabb , J. Blackburn , J. D. Crnkovic , D. W. Hertzog , B. Kiburg , J. Kunkle , E. Thorsland , D. M. Webber , K. R. Lynch

A novel concept for position-sensitive thermal neutron detectors based on thin-gap Resistive Plate Chambers (RPC) lined with a neutron converter layer is presented and its feasibility is discussed. Several detector architectures…

Instrumentation and Detectors · Physics 2018-08-29 L. M. S. Margato , A. Morozov

A differential, membrane-based nanocalorimeter for general specific heat studies of very small samples, ranging from 0.5 mg to sub-{\mu}g in mass, is described. The calorimeter operates over the temperature range from above room temperature…

Instrumentation and Detectors · Physics 2012-08-20 S. Tagliati , V. M. Krasnov , A. Rydh

The velocity of a ~3 GeV neutrino beam is measured by comparing detection times at the Near and Far detectors of the MINOS experiment, separated by 734 km. A total of 473 Far Detector neutrino events was used to measure (v-c)/c = 5.1 +/-…

High Energy Physics - Experiment · Physics 2008-11-26 MINOS Collaboration , P. Adamson

In order to carry out research in the field of possible existence of a sterile neutrino the laboratory based on SM-3 reactor (Dimitrovgrad, Russia) was created to search for oscillations of reactor antineutrino. The prototype of a…

For the purpose of withstanding very high radiation doses, silicon pixel sensors with a 3D electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as expected in the High…

Recent developments on the MicroMegas prototypes built by use of the bulk technology with analog and digital readout electronics are presented. The main test beam results of a stack of several MicroMegas prototypes fully comply with the…

Instrumentation and Detectors · Physics 2009-02-02 Catherine Adloff , Jan Blaha , Ambroise Espargiliere , Yannis Karyotakis

We report initial research to develop a compact and practical primary thermometer based on Doppler broadening thermometry (DBT). The DBT sensor uses an intrinsic property of thermalized atoms, namely, the Doppler width of a spectral line…

Atomic Physics · Physics 2025-01-29 Nicola Agnew , Graham Machin , Erling Riis , Aidan S. Arnold

The design of a low-power prototype of neutron amplifier recently proposed within the INFN-E project indicated the need for more accurate called for detailed data on the neutron yield produced by a proton beam with energy of about 70 MeV…

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built…

The response of electric devices to an applied thermal gradient has, so far, been studied almost exclusively in two-terminal devices. Here we present measurements of the response to a thermal bias of a four-terminal, quasi-ballistic…

Mesoscale and Nanoscale Physics · Physics 2012-06-15 Jason Matthews , David Sánchez , Marcus Larsson , Heiner Linke

In the domain of Fermi energy, the hot nucleus temperature can be determined by using the energy spectra of evaporated light charged particles. But this method of measurement is not without difficulties both theoretical and experimental.…

A thermal position sensor was fabricated and evaluated. The device consists of an array of temperature sensing elements, fabricated entirely on a plastic substrate. A novel fabrication technology was implemented which allows direct…

General Physics · Physics 2008-01-08 A. Petropoulos , G. Kaltsas , D. Goustouridis , A. G. Nassiopoulou

LumiCal is a sampling electromagnetic calorimeter designed for the precise measurement of integrated luminosity in electron positron linear collider experiments. The present report contains a description and results of the first beam test…

Instrumentation and Detectors · Physics 2019-08-13 Oleksandr Borysov

Knowledge of mechanical and physical property evolution due to irradiation damage is essential for the development of future fission and fusion reactors. Ion-irradiation provides an excellent proxy for studying irradiation damage, allowing…

This work reports on the performance of a novel neutron-sensitive scintillating detector fabricated using Fused-Deposition Modelling (FDM) additive manufacturing. FDM is a cost-effective 3D-printing method employing flexible plastic…

Instrumentation and Detectors · Physics 2025-10-07 Adam Barr , Cinzia da Vià , Mosst Tasnim Binte Shawkat , Stephen Watts , John Allison , Gabriele D'Amen , Tianqi Gao

The design of a neutron source capable of producing 24 and 70 keV neutron beams with narrow energy spread is presented. The source exploits near-threshold kinematics of the $^{7}$Li(p,n)$^{7}$Be reaction while taking advantage of the…

Instrumentation and Detectors · Physics 2014-05-22 T. H. Joshi , S. Sangiorgio , V. Mozin , E. B. Norman , P. Sorensen , M. Foxe , G. Bench , A. Bernstein