English
Related papers

Related papers: Thermal Neutron Measurements with an Unpowered, Mi…

200 papers

The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium…

A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV…

The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study…

Instrumentation and Detectors · Physics 2015-06-04 M. Cortesi , R. Zboray , R. Adams , V. Dangendorf , H. -M. Prasser

We present the first prototype of a novel thermal neutron detector using the time projection method. The system consists of 8 TimePix ASICS with postprocessed InGrid meshes. Each ASIC has 256 x 256 pixels of 55 mum x 55mum in size with the…

Instrumentation and Detectors · Physics 2018-12-26 M. Köhli , K. Desch , M. Gruber , J. Kaminski , F. P. Schmidt , T. Wagner

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it…

Instrumentation and Detectors · Physics 2015-05-26 M. Osipenko , F. Pompili , M. Ripani , M. Pillon , G. Ricco , B. Caiffi , R. Cardarelli , G. Verona-Rinati , S. Argiro

A new thermal neutron detector with the domestically produced THGEM (THick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was…

Instrumentation and Detectors · Physics 2014-08-06 Yang Lei , Zhou Jian-Rong , Sun Zhi-Jia , Zhang Ying , Huang Chao-Qiang , Sun Guang-Ai , Wang Yan-Feng , Yang Gui-An , Xu Hong , Xie Yu-Guang , Chen Yuan-Bo

We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint…

The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations…

Instrumentation and Detectors · Physics 2018-01-09 Paolo Finocchiaro , Luigi Cosentino , Sergio Lo Meo , Ralf Nolte , Desiree Radeck

The prototype of the hadron calorimeter module consisting of 66 scintillator/lead layers with the 15x15 cm^2 cross section and 5 nuclear interaction lengths has been designed and produced for the zero degree calorimeter of the BM@N…

Instrumentation and Detectors · Physics 2015-06-19 O. P. Gavrishchuk , V. P. Ladygin , Yu. P. Petukhov , S. Ya Sychkov

Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…

Instrumentation and Detectors · Physics 2017-04-05 S Potashev , Yu Burmistrov , A Drachev , S Karaevsky , E Konobeevski , S Zuyev

Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron…

We have designed and developed a new experimental setup, based on the 3-omega method, to measure thermal conductivity, heat capacity and electrical resistivity of a variety of samples in a broad temperature range (2-550 K) and under…

Instrumentation and Detectors · Physics 2018-04-17 K. Shrestha , K. Gofryk

Beam monitoring and evaluation are very important to boron neutron capture therapy (BNCT), and a variety of detectors have been developed for these applications. However, most of the detectors used in BNCT only have a small detection area,…

Instrumentation and Detectors · Physics 2023-06-14 Zhujun Fang , Zhiyong Zhang , Bin Shi , Wei Jiang , Xianke Liu , Siqi He , Jun Chen , Ping Cao , Jianbei Liu , Yi Zhou , Ming Shao , Botian Qu , Shufeng Zhang , Qian Wang

Here we present the thermal neutron counter from the ELI Gamma Above Neutron Threshold setup at the Extreme Light Infrastructure - Nuclear Physics. We describe the mechanical design of the setup, the properties of the ${}^{3}$He gas…

Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power…

Instrumentation and Detectors · Physics 2014-03-14 F. Piscitelli , J. C. Buffet , J. F. Clergeau , S. Cuccaro , B. Guerard , A. Khaplanov , Q. La Manna , J. M. Rigal , P. Van Esch

The temperature measurement of material inside of an object is one of the key technologies for control of dynamical processes. For this purpose, various techniques such as laser-based thermography and phase-contrast imaging thermography…

A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced…

The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron…

A possibility to measure $\sin^22\theta_{13}$ using reactor neutrinos is examined in detail. It is shown that the sensitivity $\sin^22\theta_{13}>0.02$ can be reached with 20 ton-year data by placing identical CHOOZ-like detectors at near…

High Energy Physics - Phenomenology · Physics 2014-11-17 H. Minakata , H. Sugiyama , O. Yasuda , K. Inoue , F. Suekane

A high granularity hadronic 1 m3 calorimeter prototype with semi-digital readout has been designed and built. This calorimeter has been made using stainless steel as absorber and Glass Resistive Plates Chambers (GRPC) as active medium, and…

Instrumentation and Detectors · Physics 2019-08-13 M. C Fouz
‹ Prev 1 2 3 10 Next ›