English
Related papers

Related papers: Performance study and calibration strategy of the …

200 papers

A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench…

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

With the emergence of advanced Silicon (Si) sensor technologies such as LGADs, it is now possible to achieve exceptional time measurement precision below 50 ps. As a result, the implementation of time-of-flight (TOF) particle identification…

High Energy Physics - Experiment · Physics 2023-11-09 Bohdan Dudar , Ulrich Einhaus , Jenny List , Konrad Helms , Frank Gaede

This paper describes the use of the time-of-flight (TOF) technique as a particle identification method for the HERMES experiment. The time-of-flight is measured by two 1x4 m^2 scintillation hodoscopes that initially were designed for the…

High Energy Physics - Experiment · Physics 2009-11-10 HERMES Collaboration , A. Airapetian , N. Akopov , M. Amarian , H. Avakian , A. Avetissian , E. Avetisyan , B. W. Filippone , R. Kaiser , H. Zohrabian

A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…

Instrumentation and Detectors · Physics 2016-06-01 M. Bonesini , R. Bertoni , A. deBari , M. Rossella

The barrel time-of-flight (TOF) detector for the PANDA experiment at FAIR in Darmstadt is planned as a scintillator tile hodoscope (SciTil) using 8000 small scintillator tiles. It will provide fast event timing for a software trigger in the…

Instrumentation and Detectors · Physics 2015-06-18 S. E. Brunner , L. Gruber , J. Marton , H. Orth , K. Suzuki

The High-Acceptance DiElectron Spectrometer (HADES) at GSI Darmstadt consists of a 6-coil toroidal magnet centered on the beam axis and six identical detection sections located between the coils and covering polar angles between $18^\circ$…

Instrumentation and Detectors · Physics 2023-04-05 A. Blanco , P. Fonte , L. Lopes , J. Saraiva

In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF…

Instrumentation and Detectors · Physics 2020-02-13 S. Salvador , E. Barlerin , J. Perronnel , C. Vandamme

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

Instrumentation and Detectors · Physics 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners…

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy,…

Medical Physics · Physics 2012-03-02 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

Measurement of the Time-of-Flight (TOF) of the 511 keV gammas brings an important reduction of statistical noise in the PET image, with higher precision time measurements producing clearer images. Scintillating crystals are used to convert…

Instrumentation and Detectors · Physics 2019-12-03 K. Doroud , Z. Liu , M. C. S. Williams

A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of…

The new CDFII detector incorporates a Time-of-Flight detector (TOF), employing plastic scintillator bars and fine-mesh photomultipliers. Since August 2001 the TOF system has been fully instrumented and integrated into the CDFII data…

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…

The quality of high-power impulse magnetron sputtering (HiPIMS) deposited films can often improve through the effective use of metal-ion acceleration, requiring precise measurements of time-of-flight (ToF). These measurements are commonly…

Instrumentation and Detectors · Physics 2025-10-30 Nathan Rodkey , Jyotish Patidar , Kerstin Thorwarth , Sebastian Siol

Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…

Instrumentation and Detectors · Physics 2025-11-14 José Reyes Castillo , Saúl Aguilar Salazar , Diego Mauricio Gomez Coral

Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the…

Instrumentation and Detectors · Physics 2023-04-26 L. Vergara , M. Arai , R. Woracek , M. Olsson , A. Quintanilla , S. Alcock , J. Nilsson , K. Kanaki , P. M. Kadletz , O. Kirstein , R. Hall-Wilton , N. Tsapatsaris
‹ Prev 1 2 3 10 Next ›