English
Related papers

Related papers: A low-temperature scanning probe microscopy system…

200 papers

We describe a compact ultra-high vacuum (UHV) scanning tunneling microscope (STM) system that does not need any external supply of cooling liquids. It achieves temperatures down to 1.5 K and a z-noise down to 300 fmRMS for the frequency…

The Field Ion Microscope (FIM) can be used to characterize the atomic configuration of the apex of sharp tips. These tips are well suited for Scanning Probe Microscopy (SPM) since they predetermine SPM resolution and electronic structure…

Mesoscale and Nanoscale Physics · Physics 2012-08-07 William Paul , Yoichi Miyahara , Peter Grütter

We constructed a dilution-refrigerator (DR) based ultra-low temperature scanning tunneling microscope (ULT-STM) which works at temperatures down to 30 mK, in magnetic fields up to 6 T and in ultrahigh vacuum (UHV). Besides these extreme…

Superconductivity · Physics 2009-11-13 H. Kambara , T. Matsui , Y. Niimi , H. Fukuyama

Recent advances in increasing the spectroscopic energy resolution in scanning tunneling microscopy (STM) have been achieved by integrating electron spin resonance (ESR) with STM. Here, we demonstrate the design and performance of a…

A spectroscopic imaging-scanning tunneling microscope (SI-STM) allows the atomic scale visualization of surface electronic and magnetic structure of novel quantum materials with high energy resolution. To achieve the optimal performance,…

We present an advanced scanning probe microscopy system enhanced with artificial intelligence (AI-SPM) designed for self-driving atomic-scale measurements. This system expertly identifies and manipulates atomic positions with high…

Computational Physics · Physics 2024-04-18 Zhuo Diao , Keiichi Ueda , Linfeng Hou , Fengxuan Li , Hayato Yamashita , Masayuki Abe

We report the construction and performance of a low temperature, high field scanning tunneling microscope (STM) operating down to 350mK and in magnetic fields up to 9T, with thin film deposition and in-situ cleaving capabilities. The main…

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our…

Instrumentation and Detectors · Physics 2020-02-07 Dillon Wong , Sangjun Jeon , Kevin P. Nuckolls , Myungchul Oh , Simon C. J. Kingsley , Ali Yazdani

We present the design, fabrication and discuss the performance of a new combined high-resolution Scanning Tunneling and thermopower Microscope (STM/SThEM). We also describe the development of the electronic control, the user interface, the…

In the last decade, detecting spin dynamics at the atomic scale has been enabled by combining techniques like electron spin resonance (ESR) or pump-probe spectroscopy with scanning tunneling microscopy (STM). Here, we demonstrate an…

The scanning electron microscope (SEM) delivers high resolution, high depth of focus and an image quality as if microscopic objects are seen by the naked eye. This makes it not only a powerful scientific instrument, but a tool inherently…

Applied Physics · Physics 2025-04-01 Casimir Kuzyk , Alexander Dimitrakopoulos , Alireza Nojeh

Scanning tunneling microscopy (STM) and micro-electromechanical systems (MEMS) have traditionally addressed vastly different length scales - one resolving atoms, the other engineering macroscopic motion. Here we unite these two fields to…

Mesoscale and Nanoscale Physics · Physics 2026-01-09 R. J. G. Elbertse , M. Xu , A. Keşkekler , S. Otte , R. A. Norte

Scanning Thermal Microscopy (SThM) has become an important measurement tool for characterizing the thermal properties of materials at the nanometer scale. This technique requires a SThM probe that combines an Atomic Force Microscopy (AFM)…

Mesoscale and Nanoscale Physics · Physics 2024-05-01 R. Swami , G. Julie , S. Le-Denmat , G. Pernot , D. Singhal , J. Paterson , J. Maire , J. F. Motte , N. Paillet , H. Guillou , S. Gomes , O. Bourgeois

We present a robust but still efficient simulation approach for high-resolution scanning tunneling microscopy with a flexible tip apex showing sharp submolecular features. The approach takes into account the electronic structure of sample…

Mesoscale and Nanoscale Physics · Physics 2017-01-11 O. Krejci , P. Hapala , M. Ondracek , P. Jelinek

We report on state-of-the-art scanning probe microscopy measurements performed in a pulse tube based top-loading closed-cycle cryostat with a base temperature of 4 K and a 9 T magnet. We decoupled the sample space from the mechanical and…

We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of…

Mesoscale and Nanoscale Physics · Physics 2015-06-17 A. Roychowdhury , M. A. Gubrud , R. Dana , J. R. Anderson , C. J. Lobb , F. C. Wellstood , M. Dreyer

We show that a scanning capacitance microscope (SCM) can image buried delta-doped donor nanostructures fabricated in Si via a recently developed atomic-precision scanning tunneling microscopy (STM) lithography technique. A critical…

Scanning probe microscopy (SPM) images of regularly arranged spatially periodic objects can be processed crystallographically. The resulting information may be used to remove from the SPM image distortions that are due to a less than…

Materials Science · Physics 2020-12-16 Peter Moeck

A home made DSP-controlled scanning probe microscope (SPM) system has been developed and its utilization as a tool for lithography on nanometer scale is reported. User-friendly graphic interface allows to directly perform nanolithography…

Materials Science · Physics 2007-05-23 Pasqualantonio Pingue , Paolo Baschieri , Cesare Ascoli , Michel Dayez

A cryo scanning transmission X-ray microscope, the cryo-STXM, has been designed and commissioned at the Canadian Light Source synchrotron. The instrument is designed to operate from 100 - 4000 eV (lambda = 12.4 - 0.31 nm). Users can insert…