Related papers: Property investigation for different wedge-shaped …
Crystal scintillators provide potential merits for the pursuit of low-energy low-background experiments. A CsI(Tl) scintillating crystal detector is being constructed to study low-energy neutrino physics at a nuclear reactor, while projects…
Characterization of a hybrid ${\it telescope}$ with gas transmission detector ($\Delta$E) and a solid-state stop detector (E) has been fabricated for detection of low energy $\alpha$ particles between 5 to 1 MeV. The detector is developed…
GAGG(Ce) is a novel scintillator with a fast response and high light output without a hygroscopic nature. It is expected to be a useful detector for charged particles at high-counting rates. However, the response of the GAGG(Ce)…
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um…
The light output of the 324 CsI(Tl) scintillators of INDRA has been measured over a large range both in energy: 1 - 80 AMeV and in atomic number of incident ions: Z = 1 - 60. An analytical expression for the nonlinear total light response…
The in-beam tests of two Si pixel type TRACE detectors have been performed at Laboratori Nazionali di Legnaro (Italy). The aim was to investigate the possibility of identifying heavy-ion reactions products with mass A~10 at low kinetic…
The absence of conclusive signals in weakly interacting massive particle (WIMP) searches has motivated increased interest in alternative dark matter candidates such as axions and axion-like particles (ALPs), which also provide a solution to…
A silicon particle-telescope system for light-ion nuclear reactions is described. In particular, the system is designed to be optimized for level density and gamma-ray strength function measurements with the so-called Oslo method. Eight…
We report on the development of the thallium-doped cesium iodide (CsI:Tl) calorimeter subsystem for the All-Sky Medium-Energy Gamma-ray Observatory (AMEGO) [1]. The CsI:Tl calorimeter is one of the three main subsystems that comprise the…
Scintillating crystal detector may offer some potential advantages in the low-energy, low-background experiments. A 500 kg CsI(Tl) detector to be placed near the core of Nuclear Power Station II in Taiwan is being constructed for the…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…
For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type.…
The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a…
In the present work, cesium iodide (CsI) thin films of different thickness have been prepared by thermal evaporation technique. The crystallite size and grain size of these films are compared by using X-ray diffraction (XRD) profile…
The scintillation mechanism in NaI:Tl crystals produces different pulse shapes that are dependent on the incoming particle type. The time distribution of scintillation light from nuclear recoil events decays faster than for electron recoil…
(Gd,La)$_2$Si$_2$O$_7$:Ce (La-GPS:Ce) is a new scintillator material with high light output, high energy resolution, and fast decay time. Moreover, the scintillator has a good light output even at high temperature (up to 150$^\circ$C) and…
A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated…
We propose a new functional for the charge and mass identification in Delta E-E telescopes. This functional is based on Bethe's formula, allowing safe interpolation or extrapolation in regions with low statistics. When applied to telescopes…
A high-granularity telescope system with a large sensitive area and low material budget has been developed for high-energy heavy ion beam tests. The telescope consists of nine layers of silicon microstrip detectors (SSDs), whose performance…