Related papers: Comparison between Thermoelectric and Bolometric M…
We have developed two analytical models to describe the performance of cryogenic microcalorimeters and bolometers. One of the models is suitable to describe Transition Edge Sensor (TES) detectors with an integrated absorber, the other is…
This is the report on new development of an automated precision load-based measurement setup for thermoelectric power of different types of samples in the temperature range 5 - 330 K. The problems in the old spring-based setup have been…
A low-power wearable wireless sensor measuring both molecular biomarkers and physiological signals is proposed, where the former are measured by a microfluidic biosensing system while the latter are measured electrically. The low-power…
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…
The ability to control and measure the temperature of propagating microwave modes down to very low temperatures is indispensable for quantum information processing, and may open opportunities for studies of heat transport at the nanoscale,…
We have studied the accuracy of the atomic microwave power standard. The atoms are cooled and kept in a Magneto-Optical Trap (MOT), then dropped through a terminated transmission line (a rectangular, R-70 type, waveguide). The measurement…
Motivated by the recent development of fast and ultra-sensitive thermometry in nanoscale systems, we investigate quantum calorimetric detection of individual heat pulses in the sub-meV energy range. We propose a hybrid superconducting…
The complex ac impedance of a bolometer or microcalorimeter detector is easily measured and can be used to determine thermal time constants, thermal resistances, heat capacities, and sensitivities. Accurately extracting this information…
Microwave photonic (MWP) signal processors, which process microwave signals based on pho-tonic technologies, bring advantages intrinsic to photonics such as low loss, large processing bandwidth, and strong immunity to electromagnetic…
We perform experimental and theoretical study of the parallel-series arrays of Cold-Electron Bolometers (CEBs) integrated into a cross-slot antenna and composed with an immersion silicon lens. The purpose is to determine the absorption…
A novel approach to calibrate the sensitivity of a differential thermometer, consisting of several thermocouples connected in series (thermopile), has been developed. The goal of this method is to increase the accuracy of small temperature…
A modified AC method based on micro-fabricated heater and resistive thermometers has been applied to measure the thermopower of microscale samples. A sinusoidal current with frequency {\omega} is passed to the heater to generate an…
A differential, membrane-based nanocalorimeter for general specific heat studies of very small samples, ranging from 0.5 mg to sub-{\mu}g in mass, is described. The calorimeter operates over the temperature range from above room temperature…
The operation of the primary Coulomb blockade thermometer (CBT) is based on a measurement of bias voltage dependent conductance of arrays of tunnel junctions between normal metal electrodes. Here we report on a comparison of a CBT with a…
We report measurements of the energy resolution of ultra-sensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single…
Wearable biosensors increasingly require continuous and battery-free power sources, but conventional skin-mounted thermoelectric generators are limited by the small temperature differences available in real environments. This work…
We outline calibrated measurements of the microwave reflection coefficient from the tunnel junction of an ultra-high vacuum low temperature scanning tunneling microscope. The microwave circuit design is described in detail, including an…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
We provide a detailed description of the quantum interferometric thermometer, which is a device that estimates the temperature of a sample from the measurements of the optical phase. For the first time, we rigorously analyze the operation…
We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for…