Related papers: Scanning SQUID microscopy in a cryogen-free diluti…
The investigation of novel electronic phases in low-dimensional quantum materials demands for the concurrent development of new measurement techniques that combine surface sensitivity with high spatial resolution and high measurement…
A hybrid quantum computing architecture combining quantum processors and quantum memory units allows for exploiting each component's unique properties to enhance the overall performance of the total system. However, superconducting qubits…
Miniaturization of superconducting quantum interference devices (SQUIDs) is of major importance for the development of sensitive scanning nanoscale magnetometry tools. The high sensitivity of nanoSQUIDs is restricted, however, to only…
Scanning superconducting quantum interference device microscopy (SSM) is a scanning probe technique that images local magnetic flux, which allows for mapping of magnetic fields with high field and spatial accuracy. Many studies involving…
We investigate electric transport and noise properties of microstrip-type submicron direct current superconducting quantum interference devices (dc SQUIDs) based on Nb thin films and overdamped Josephson junctions with a HfTi barrier. The…
We have developed a nuclear magnetic resonance spectrometer with a series tuned input circuit for measurements on samples at millikelvin temperatures based on an integrated two-stage superconducting quantum interference device current…
We have developed a system for tapered fiber measurements of optomechanical resonators inside a dilution refrigerator, which is compatible with both on- and off-chip devices. Our apparatus features full three-dimensional control of the…
We demonstrate a dynamic scanning capacitance microscope (DSCM) that operates at large bandwidths, cryogenic temperatures and high magnetic fields. The setup is based on a non-contact atomic force microscope (AFM) with a quartz tuning fork…
We present the realization and characterization of a novel-concept interferometer, the superconducting quantum interference proximity transistor (SQUIPT). Its operation relies on the modulation with the magnetic field of the density of…
Signal to noise ratios (SNR) in magnetic resonance microscopy images are limited by acquisition times and the decreasing number of spins in smaller voxels. Significant SNR gains from cooling of the RF receiver are only realized when the…
We carry out a quantum analysis of a dc SQUID mechanical displacement detector, comprising a SQUID with mechanically compliant loop segment, which is embedded in a microwave transmission line resonator. The SQUID is approximated as a…
Careful filtering is necessary for observations of quantum phenomena in superconducting circuits at low temperatures. Measurements of coherence between quantum states requires extensive filtering to protect against noise coupled from room…
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses…
SQUID-embedded superconducting resonators are of great interest due to their potential for coupling highly scalable superconducting circuits with quantum memories based on solid-state spin ensembles. Such an application requires a high-$Q$,…
Significant advancements have been made in understanding the physics of transition-edge sensors (TESs) over the past decade. However, key questions remain, particularly a detailed understanding of the current-dependent resistance of these…
The search for primordial B-modes in the cosmic microwave background (CMB) requires highly sensitive and scalable detector systems. The magnetic microbolometer (MMB) is an emerging detector concept that exploits the magnetic properties of…
Magnetic skyrmions in bulk materials are typically regarded as two-dimensional structures. However, they also exhibit three-dimensional configurations, known as skyrmion tubes, which elongate and extend in-depth. Understanding the…
Quantum sensors based on solid-state defects, in particular nitrogen-vacancy (NV) centers in diamond, enable precise measurement of magnetic fields, temperature, rotation, and electric fields. However, the sensitivity of leading NV spin…
Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) because lower SQUID inductance…
We report on the design and implementation of a rotating sample magnetometer (RSM) operating in the variable temperature insert of a cryostat equipped with a high-field magnet. The limited space and the cryogenic temperatures impose the…